What should I pay attention to when choosing an evaporator for an ultra-low temperature chiller?

The evaporator in the ultra-low temperature chiller is one of its four major components, so performance is more important.

The selection of ultra-low temperature chillers needs to pay attention to the influence of liquid level on the evaporation temperature. Due to the influence of the height of the refrigerant liquid column, the evaporation temperature at the bottom of the flooded evaporator is higher than the evaporation temperature of the liquid surface. The evaporation temperature of different refrigerants at different liquid levels is affected differently by the height of the static liquid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the influence of the hydrostatic height on the evaporation temperature. Therefore, only when the evaporation pressure is high, the influence of the hydrostatic height on the evaporation temperature can be ignored. When the evaporation temperature is low, it cannot be ignored. In other words, it becomes uneconomical to use a flooded evaporator at this time.


If the evaporation temperature is lower than the freezing temperature of the refrigerant, the refrigerant may freeze. In the subsequent flow of the refrigerant, the temperature of the refrigerant is low, and the possibility of freezing is high. When water is used as the refrigerant, theoretically, the temperature of the inner wall of the tube can be as low as 0°C. However, for safety reasons, the temperature of the inner wall of the pipe at the outlet end of the next process is usually kept above 0.5°C. In the case of brine as the refrigerant, according to the same principle, the temperature of the inner wall of the tube should be higher than the freezing temperature of the refrigerant by more than 1°C.

When the refrigerant flows through the evaporator, pressure loss is caused, which will inevitably make the pressure p2 of the refrigerant at the outlet of the evaporator be lower than the pressure p1 at the inlet, thereby reducing the suction pressure of the compressor, resulting in a decline in the refrigeration capacity.

According to different models, the choice of evaporator is different. For example, the box-type small ultra-low temperature chiller uses a water tank coil type evaporator; the open-type small ultra-low temperature chiller and the screw-type small ultra-low temperature chiller use shell and tube Type evaporator; for acid and alkali resistant ultra-low temperature chillers, you can choose titanium tube evaporator or stainless steel plate exchanger; there are many options, of course, it can be customized according to user needs.

The ultra-low temperature chiller evaporator is generally designed and equipped by the ultra-low temperature freezing test manufacturer. It is recommended that users check the configuration problems when choosing the ultra-low temperature chiller manufacturer.
Related News
Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • LT -45℃~30℃

    LT -45℃~30℃

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
  • IC Test Temperature System      -45℃~250℃

    IC Test Temperature System -45℃~250℃

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • Flash EMMC Temperature Test  -85℃~200℃

    Flash EMMC Temperature Test -85℃~200℃

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view
products
Contact
Tel: + 86 18751545184
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat