TES -85℃~200℃
cooling heating system temperature control Semiconductor test chiller- Heating Power2.5kW~25kW
- Cooling capacity0.25kW~25kW
- Power range6.5kW~50kW
- Medium accuracy±0.3℃
- Flow pressure20L/min~150L/min 2.5bar
- RefrigerantR404A/R508B
Product data download
Temperature control range:-85°C ~ 200°C ;Power range:6.5kW~50kW;Temperature control accuracy:±0.3°C
Chip-Specific High and Low Temperature Test Boxes In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing at temperatures (-85 °C to +200 °C) and other environments. Test the simulation. Once put into practical use, these semiconductor devices and electronic products can be exposed to extreme environmental conditions to meet demanding military and telecommunications reliability standards.
LNEYA represents the international advanced liquid temperature control technology, actively explores and studies component testing systems, mainly used for temperature test simulation in semiconductor testing, with wide temperature orientation and high temperature rise and fall, temperature range -92°C ~ 250°C, suitable for various Test Requirements. LNEYA is committed to solving the problem of temperature control lag in electronic components. Ultra high temperature cooling technology can be cooled directly from 300°C.
Parameters
Model | TES-8525W | TES-8555W | TES-85A10W | TES-85A15W | TES-85A25W | |
Temp. Range | -85℃~200℃ | -85℃~200℃ | -85℃~200℃ | -85℃~200℃ | -85℃~200℃ | |
Heating Power | 2.5kW | 5.5kW | 10kW | 15kW | 25kW | |
Refrigerating Output | 200℃ | 2.5kW | 5.5kW | 10kW | 15kW | 25kW |
100℃ | 2.5kW | 5.5kW | 10kW | 15kW | 25kW | |
20℃ | 2.5kW | 5.5kW | 10kW | 15kW | 25kW | |
0℃ | 2.5kW | 5.5kW | 10kW | 15kW | 25kW | |
-40℃ | 1.5kW | 3.3kW | 6.5kW | 11kW | 20kW | |
-60℃ | 0.85kW | 1.8kW | 3.4kW | 6.5kW | 10kW | |
-80℃ | 0.25kW | 0.45kW | 1.5kW | 2.5kW | 4kW | |
Temp. Control Accuracy of Heat Conduction Medium | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
System Pressure Display | Pressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure); | |||||
Pressure of circulatory system is detected by pressure sensor and displayed on touch screen. | ||||||
Controller | Siemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm. | |||||
Temp. Control | Temperature Control Mode for outlet of Heat conduction medium; | |||||
External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control) | ||||||
Programmable | 5 procedures can be developed, and each program can be composed of 40 steps | |||||
Communicating Protocol | Ethernet Interface TCP/IP Protocol | |||||
Internal Temperature Feedback | Outlet temperature, inlet temperature, condensing temperature, ambient temperature, suction temperature of compressor, cooling water temperature (water cooling equipment configuration) of equipment heat conduction medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature. | |||||
External Access Temp Feedback | PT100 or 4~20mA or communication given. | |||||
Cascade control time | The temperature difference between the outlet temperature and the external temperature sensor can be set and controlled; | |||||
Temp. difference control function | The temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system). | |||||
Closed-cycle system | The whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature. | |||||
Heating Power | The maximum heating output power of the system (According to each model); | |||||
The heater has triple protection and independent temperature limiter to ensure the safety of heating system; | ||||||
The power is more than 10kW and the voltage regulator is adopted, and the heating power output control is controlled by 4-20mA linear control. | ||||||
Refrigerating Capacity | Refers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures. | |||||
Circulating pump flow (max) | Magnetic drive pump | |||||
20L/min2.5bar | 50L/min2.5bar | 50L/min2.5bar | 110L/min2.5bar | 150L/min2.5bar | ||
Compression Engine | Tecumseh | Emerson Scroll flexible compressor | ||||
Evaporimeter | Plate heat exchanger | |||||
Refrigeration Accessory | Danfoss / Emerson accessories (dry filters, oil separators, high and low pressure protectors, mirrors) | |||||
Expansion Valve | Danfoss thermal expansion valve+Emerson electronic expansion valve | |||||
Operation Panel | LNEYA custom 7-inch color touch screen, temperature curve display\ EXCEL data export | |||||
Safe Guarding | With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. | |||||
Cryogen | R404A R508B | |||||
Interface size | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 RF | |
External dimension (water cooling) | 55*70*175 | 65*85*185 | 80*120*185 | 100*150*185 | 200*145*205 | |
Water-cooled W | Type W is water cooled | |||||
Water-cooled Condenser | Casing heat exchanger (Paris / Shen’s) | |||||
Cooling Water At 20 ℃ | 2000L/H | 2400L/H | 3500L/H | 5200L/H | 12m³/H | |
1.5bar~4bar | 1.5bar~4bar | 1.5bar~4bar | 1.5bar~4bar | 1.5bar~4bar | ||
Power 380V50HZ | 7.5kW max | 13kW max | 22kW max | 32kW max | 54kW max | |
Optional | AC 380V 50HZ Three-phase five-wire system | |||||
Customizable 460V 60HZ、220V 60HZ Three-phase | ||||||
Shell Material | Cold rolled sheet spray (Standard Colour 7035) | |||||
Isolation Explosion Proof | Customizable isolation explosion-proof(EXdIIBT4) | |||||
LNEYA Explosive proof product installation license number:PCEC-2017-B025 | ||||||
Barotropic Explosion Protection | Customizable barotropic explosion-proof (EXPXdmbIICT4) barotropic systems must be water-cooled equipment; | |||||
LNEYA Explosive product installation license number: PCEC-2017-B025 |
Product Description
Temperature control range:-85°C ~ 200°C ;Power range:2.5kW~25kW;Temperature control accuracy:±0.3°C
Chip-Specific High and Low Temperature Test Boxes In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing at temperatures (-85°C to +200°C) and other environments. Test the simulation. Once put into practical use, these semiconductor devices and electronic products can be exposed to extreme environmental conditions to meet demanding military and telecommunications reliability standards.
You may also be interested in these products
Air Cooling Chiller AET SERIES
Parameters DetailedProductDescriptionREQUEST A QUOTERecommended products Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc….
MD -75℃~225℃
Quick temperature change control chuckConfiguration DetailsProduct Description -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…
YQH 0℃~-75℃
Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products Suitable for the recovery of various volatile VOCs gases; Fast c…
FLT-100℃~90℃ low temperature cascade
Product data downloadConfiguration Detailschillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products Model FLTZ-803W FLTZ-805W FLTZ-806W FLT-Z808W FLTZ-810W Temp Range -80℃~+90℃ …
loading…
已经是到最后一篇内容了!