Normal & Low Temperature Chillers -40℃~160℃
Control Temperature & Flow Systems
For Vehicle Components Testing,Hydrogen energy industry
Control temperature & flow system supports one to many, meaning that one refrigeration and heating temperature control flow host can control 2-6 different test benches or demand temperature control flow devices. Support two one to many modes, one is that temperature/flow/pressure can be independently controlled (T-series), and the other is that temperature is consistent across multiple groups, and flow/pressure is independently controlled (S-series).(LNEYA’s chiller supports both indoor and outdoor options.)
The automotive industry must ensure that its products operate over this wide temperature range and do not fail or material fatigue under rapid temperature changes.
Therefore, material and component testing, including temperature simulation, is very important and indispensable for the automotive industry, including all suppliers.
On the test benches in the automotive industry, highly dynamic temperature control systems are used for material and component testing, which can achieve precise regulation and rapid temperature changes. Only precise temperature management can provide reliable and repeatable results. The temperature control system provides a constant temperature or a complex temperature curve to the test bench directly or indirectly through a liquid medium. In addition to the temperature of the medium, temperature control systems also allow precise control of flow rates and operating pressures. Temperature control systems are used primarily in two ways: They simulate external ambient conditions in climate chambers or replace internal systems, such as the cooling circuit of an engine. The latter allows realistic conditions to be created on test benches, where test specimens are supplied with coolant according to operational requirements, such as in a vehicle.
We supply our customers in the automotive industry with high-performance devices. They not only dynamically cover the entire temperature range from -40°C to +160°C and the rapid temperature changes required on test benches.
KRY series advantages
● Efficient production stability and repeatability results;
● Using plate heat exchangers and pipeline heaters to improve cooling and heating rates;
● Very wide temperature range, no need to replace liquid medium;
● Fully enclosed system, extending the lifespan of thermal conductive liquids;
● Adopting magnetic drive pump, there is no problem of shaft seal leakage
LOW TEMPERATURE SERIES
KRY -20℃~+100℃
Model |
KRY-255 KRY-255W |
KRY-275 KRY-275W |
KRY-2A10 KRY-2A10W |
KRY-2A15 KRY-2A15W |
KRY-2A25 KRY-2A25W |
KRY-2A38W |
Temp Range |
-20℃~+100℃ |
Temp control accuracy |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Flow rate output |
1~15 L/min |
1~25 L/min |
1~30 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
Flow rate accuracy |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
Heating capacity |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
Cooling capacity |
100℃ |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
20℃ |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
0℃ |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
-15℃ |
2.8kW |
3.8kW |
4.6kW |
7kW |
12kW |
16kW |
Connection size |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
Water-cooled type W at 25℃ |
1900L/H ZG3/4 |
2500L/H ZG3/4 |
3000L/H ZG1 |
4000L/H ZG1 |
6000L/H DN32 |
9000L/H DN40 |
Power 380V50HZ |
11kW |
14kW |
19kW |
23kW |
31kW |
45kW |
Dimension cm |
55*100*175 |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
Weight |
230kg |
250kg |
300kg |
320kg |
570kg |
830kg |
Optional |
Extend to -40~+135℃ |
KRY -40℃~+100℃
Model |
KRY-455 KRY-455W |
KRY-475 KRY-475W |
KRY-4A10 KRY-4A10W |
KRY-4A15 KRY-4A15W |
KRY-4A25 KRY-4A25W |
KRY-4A38W |
KRY-4A60W |
Temp Range |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
Temp control accuracy |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Flow rate output |
1~25 L/min |
1~25 L/min |
1~25 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
Flow rate accuracy |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
Heating capacity |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
60kW |
Cooling capacity |
100℃ |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
60kW |
20℃ |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
60kW |
0℃ |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
60kW |
-20℃ |
2.8kW |
4.5kW |
6kW |
10kW |
16kW |
25kW |
35kW |
-35℃ |
1.2kW |
1.8kW |
2.5kW |
4kW |
6.5kW |
10kW |
15kW |
Connection size |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
Water-cooled type Wat25度 |
1900L/H ZG3/4 |
2500L/H ZG3/4 |
3000L/H ZG1 |
4000L/H ZG1 |
6000L/H DN32 |
9000L/H DN40 |
15000L/H DN50 |
Power 380V50HZ |
10kW |
14kW |
17kW |
25kW |
38kW |
58kW |
84kW |
Dimension cm |
55*100*175 |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
200*145*205 |
Weight |
250kg |
280kg |
320kg |
360kg |
620kg |
890kg |
1300KG |
Optional |
Extend to -40~+135℃ |
KRY -40℃~+100℃ 2T
Model |
KRY-475/2T KRY-475W/2T |
KRY-4A15W/2T |
KRY-4A25W/2T |
KRY-4A38W/2T |
KRY-4A60W/2T |
Temp Range |
-40℃~+100℃ |
Temp control accuracy |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Flow control accuracy/Group |
1~25 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
Flow rate accuracy/group |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
Number of fuid output groups |
2 groups |
2 groups |
2 groups |
2 groups |
2 groups |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Heating capacity |
7.5kW*2 |
10kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
Cooling capacity |
100℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
20℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
0℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
-20℃ |
4.5kW*2 |
8.5kW*2 |
14kW*2 |
22kW*2 |
35kW*2 |
-35℃ |
1.8kW*2 |
4kW*2 |
6.5kW*2 |
10kW*2 |
15kW*2 |
Water-cooled type Wat 20度 |
4000L/H ZG1 |
8000L/H DN32 |
12000L/H DN40 |
20000L/H DN50 |
30000L/H DN65 |
Dimension cm |
28kW |
45kW |
70kW |
108kW |
158kW |
Water-cooled cm |
80*100*185 |
100*150*185 |
200*145*205 |
200*145*205 |
250*145*225 |
Weight |
660KG |
850KG |
1350KG |
1800KG |
2600KG |
Optional |
Extend to -40~+135℃ |
KRY -20℃~+100℃ 6S
Model |
KRY-2A25W/6S |
KRY-2A38W/6S |
KRY-2A60W/6S |
Temp Range |
-20℃~+100℃ |
Temp control accuracy |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Flow control accuracy/Group |
1~25 L/min |
1~25 L/min |
1~40 L/min |
Flow rate accuracy/group |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
Number of fuid output groups |
6 groups |
6 groups |
6 groups |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Heating capacity |
15kW |
25kW |
38kW |
Cooling capacity |
100℃ |
25kW |
38kW |
60kW |
20℃ |
25kW |
38kW |
60kW |
0℃ |
25kW |
38kW |
60kW |
-15℃ |
10kW |
15kW |
24kW |
Water-cooled type Wat 20度 |
8000L/H DN40 |
12000L/H DN50 |
20000L/H DN65 |
Power 380V50HZ |
36kW |
51kW |
75kW |
Water-cooled cm |
200*145*205 |
200*145*205 |
200*145*205 |
Weight |
900kg |
1100kg |
1750kg |
KRY -40℃~+100℃ 6S
Model |
KRY-4A25W/6S |
KRY-4A38W/6S |
KRY-4A60W/6S |
Temp Range |
-40℃~+100℃ |
Temp control accuracy |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Flow control accuracy/Group |
1~25 L/min |
1~25 L/min |
1~40 L/min |
Flow rate accuracy/group |
±0.2 L/min |
±0.2 L/min |
±0.2 L/min |
Number of fuid output groups |
6 groups |
6 groups |
6 groups |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Heating capacity |
15kW |
25kW |
38kW |
Cooling capacity |
100℃ |
25kW |
38kW |
60kW |
20℃ |
25kW |
38kW |
60kW |
0℃ |
25kW |
38kW |
60kW |
-20℃ |
14kW |
22kW |
35kW |
-35℃ |
5kW |
8kW |
13kW |
Water-cooled type Wat 20度 |
8000L/H DN40 |
12000L/H DN50 |
18000L/H DN65 |
Power 380V50HZ |
38kW |
55kW |
82kW |
Dimension cm |
200*145*205 |
200*145*205 |
200*145*205 |
Weight |
900kg |
1200kg |
1950kg |
Optional |
Extend to -40~+135℃ |
NORMAL TEMPERATURE SERIES
KRY 0℃~+100℃
Model |
KRY-25 |
KRY-55 |
KRY-75 |
KRY-A10 |
KRY-A15 KRY-A15W |
KRY-A25 KRY-A25W |
KRY-A38W |
KRY-A60W |
Temp Range |
0℃~+100℃ |
Temp control accuracy |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Flow rate output |
2~20 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
5~50 L/min |
5~50 L/min |
Flow rate accuracy |
±0.2 L/min |
Heating capacity |
2.5kW |
5.5kW |
7.5kW |
10kW |
15kW |
15kW |
25kW |
38kW |
Cooling capacity |
100℃ |
2.5kW |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
60kW |
20℃ |
2.5kW |
5.5kW |
7.5kW |
10kW |
15kW |
25kW |
38kW |
60kW |
5℃ |
1.8kW |
3.8kW |
5.2kW |
7kW |
11kW |
18kW |
27kW |
42kW |
Connection size |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
Water-cooled type Wat25度 |
|
|
|
|
3200L/H ZG1 |
6000L/H G1 1/4 |
9000L/H DN40 |
15000L/H DN50 |
Power 380V50HZ |
4.5kW220V |
8.5kW |
11.5kW |
16kW |
18kW |
28kW |
40kW |
61kW |
Dimension cm |
50*85*145 |
55*100*175 |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
100*150*185 |
Weight |
220kg |
250kg |
280kg |
320kg |
360kg |
620kg |
890kg |
1300KG |
KRY 0℃~+100℃ 2T
Model |
KRY-25/2T |
KRY-55/2T |
KRY-75/2T |
KRY-A10/2T |
KRY-A15W//2T |
KRY-A25W/2T |
KRY-A38W/2T |
KRY-A60W/2T |
Temp Range |
0℃~+100℃ |
Temp control accuracy |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Flow rate output |
2~20 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
5~50 L/min |
5~50 L/min |
Flow rate accuracy |
±0.2 L/min |
Heating capacity |
2.5kW*2 |
5.5kW*2 |
7.5kW*2 |
10kW*2 |
15kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
Cooling capacity |
100℃ |
2.5kW*2 |
5.5kW*2 |
7.5kW*2 |
10kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
20℃ |
2.5kW*2 |
5.5kW*2 |
7.5kW*2 |
10kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
5℃ |
1.8kW*2 |
3.8kW*2 |
5.2kW*2 |
7kW*2 |
11kW*2 |
18kW*2 |
27kW*2 |
42kW*2 |
Connection size |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
Water-cooled type Wat25度 |
|
|
|
|
5600L/H DN32 |
10000L/H DN40 |
17000L/H DN50 |
24000L/H DN65 |
Power 380V50HZ |
9kW |
19kW |
23kW |
29kW |
34kW |
52kW |
80kW |
120kW |
Dimension cm |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
200*145*205 |
200*145*205 |
250*145*225 |
Weight |
260KG |
320KG |
400KG |
580KG |
750KG |
1250KG |
1600KG |
2400KG |
KRY 0℃~+100℃ 6S
Model |
KRY-A25W/6S |
KRY-A38W/6S |
KRY-A60W/6S |
Temp Range |
0℃~+100℃ |
Temp control accuracy |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Flow control accuracy/Group |
2~25 L/min |
2~25 L/min |
2~25 L/min |
Flow rate accuracy/group |
±0.2L/min |
Number of fuid output groups |
6 groups |
6 groups |
6 groups |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Heating capacity |
15kW |
25kW |
38kW |
Cooling capacity |
100℃ |
25kW |
38kW |
60kW |
20℃ |
25kW |
38kW |
60kW |
5℃ |
18kW |
27kW |
42kW |
Water-cooled type Wat 20度 |
6000L/H DN32 |
9000L/H DN40 |
15000L/H DN50 |
Power 380V50HZ |
38kW |
55kW |
82kW |
Dimension cm |
200*145*205 |
200*145*205 |
200*145*205 |
Weight |
900kg |
1200kg |
1950kg |
Frequency Conversion Series
KRYZ -40℃~+100℃
Model |
KRYZ-475 KRYZ-475W |
KRYZ-4A15W |
KRYZ-4A25W |
Temp Range |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
Temp control accuracy |
±0.1℃ |
±0.1℃ |
±0.1℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Flow rate output |
1~25 L/min |
1~25 L/min |
1~25 L/min |
Flow rate accuracy |
±0.1 L/min |
±0.1 L/min |
±0.1 L/min |
Heating power |
7.5kW |
15kW |
25kW |
Cooling capacity |
100℃ |
7.5kW |
15kW |
25kW |
20℃ |
7.5kW |
15kW |
25kW |
0℃ |
7.5kW |
15kW |
25kW |
-20℃ |
4.5kW |
10kW |
16kW |
-35℃ |
1.8kW |
4kW |
6.5kW |
Connection size |
G3/4 |
G3/4 |
G3/4 |
Water-cooled At20℃ |
2500L/H ZG3/4 |
4000L/H ZG1 |
6000L/H DN32 |
Power 380V50HZ |
14kW |
25kW |
38kW |
Dimension cm |
55*85*175 |
70*100*175 |
80*120*185 |
Weight |
280kg |
360kg |
620kg |
Optional |
Extended to -40 ℃~+135 ℃ |
KRYZ -40℃~+100℃ 2T
Model |
KRYZ-475W/2T |
KRYZ-4A15W/2T |
KRYZ-4A25W/2T |
Temp Range |
-40℃~+100℃ |
Temp control accuracy |
±0.1℃ |
±0.1℃ |
±0.1℃ |
Temp feedback |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Flow rate output |
1~25 L/min |
1~25 L/min |
1~25 L/min |
Flow control accuracy/Group |
±0.1 L/min |
±0.1 L/min |
±0.1 L/min |
Number of fuid output groups |
2 groups |
2 groups |
2 groups |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Heating power |
7.5kW*2 |
10kW*2 |
15kW*2 |
Cooling capacity |
100℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
20℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
0℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
-20℃ |
4.5kW*2 |
8.5kW*2 |
14kW*2 |
-35℃ |
1.8kW*2 |
4kW*2 |
6.5kW*2 |
Water-cooled At20℃ |
4000L/H ZG1 |
8000L/H DN32 |
12000L/H DN40 |
Dimension cm |
80*120*185 |
100*150*185 |
200*145*205 |
Power 380V50HZ |
28kW |
45kW |
70kW |
Weight |
660KG |
850kg |
1350kg |
Optional |
Extended to -40 ℃~+135 ℃ |
Hourly power consumption kWh |
-40℃ |
-10℃ |
20℃ |
KRY-475 |
5 |
6.2 |
8.4 |
KRYZ-475 |
2.2 |
4 |
4.8 |
Frequency conversion saves power consumption |
56% |
35% |
43% |
Explain |
1. Empty load test data; 2. The test condition is an ambient temperature of 20 ℃; 3. Flow rate 15L/min |
Oil cooling chiller for motor test
KRYZ 0℃~+160℃
Model |
KRYO-A15W |
KRYO-A25W |
KRYO-A38W |
KRYO-A15W2S |
KRYO-A25W2S |
KRYO-A38W2S |
Temp Range |
0℃ ~ +160℃ Different viscosity oils have different temperature ranges |
Temp control accuracy |
±0.3℃ |
Flow rate accuracy |
±0.2L/min |
Pressure control |
0.2bar~2.5bar |
Heating power |
15kW |
25kW |
38kW |
15kW |
25kW |
38kW |
Cooling capacity |
125℃ |
15kW |
25kW |
38kW |
15kW |
25kW |
38kW |
20℃ |
12kW |
20kW |
30kW |
12kW |
20kW |
30kW |
Refrigerant |
R410A |
Secondary refrigerant |
Oil |
Connection size |
G3/4 |
Water-cooled At20℃ |
3000L/H |
4200L/H |
6200L/H |
3000L/H |
4200L/H |
6200L/H |
Connection size |
G3/4 |
G3/4 |
G1 |
G3/4 |
G3/4 |
G1 |
direct cooling heating series
Can meet the direct cooling/direct heating for battery pack and vehicle testing and testing. This equipment is mainly used for cooling and heating capacity testing. It uses variable frequency compressor with adjustable output;
KRYZ 0℃~+160℃
Model |
KRYZ-5W-ZLH |
KRYZ-5W-ZL |
KRYZ-5-ZLH |
KRYZ-5-ZL |
Cooling capacity |
0.5kW~10kW |
0.5kW~10kW |
Heating capacity |
0.5kW~10kW |
|
Undercooling degree |
Refrigeration 0k~8K Heating at 0k~6k in low-temp environment, 6k~20k |
Refrigeration 0k~8K |
Overheating degree |
Refrigeration 2k~20k Heating 2k~10k |
Refrigeration 2k~20k |
Condensation pressure control accuracy |
Better than ±50kpa |
Better than ±50kpa |
Suction pressure |
300kpa~600kpa ±10kpa |
300kpa~600kpa ±10kpa |
Battery pack testing environment Temp |
-40℃~50℃ |
-40℃~50℃ |
multi-channel independent temperature control
Adopts LNEYA PLC control, simple menu navigation, 7″ color large screen, multi-faceted and multi-functional images to display comprehensive important data information. The newly added safety measures ensure continuous unattended operation. All relevant operating status data are continuously monitored and visualized on the touch screen. Supports one-to-many multi-channel independent control, and each group can be set independently.
Appearance details
Application cases
The testing unit needs to use specific temperature change curves and record temperature changes; The temperature range is usually -40 ℃ to 100 ℃ (can expand to 150 ℃); When conducting tolerance testing, it is usually done in an infinite cycle.
High adaptability and wide applicationS
Suitable for more simulation test temperature control
Equipment application: new energy battery pack, battery module, battery cell, motor and controller, charger, DC/DC converter, electronic pump
REQUEST A QUOTE
Recommended products
Temperature Control :-5℃~-150℃
Temperature control for Various reactors, distillation or extraction systems, laboratories, research institutes, chemical, pharmaceutical, petrochemical, biochemical, medical, hospital, research and development workshops, semiconductor testing, aerospace, biology.
Temperature Control :-120℃~350℃
Temperature control for high pressure reactor;Double-layer glass reactor;Double-layer reactor;Microchannel Reactor;Distillation system;Material aging test;Vacuum chamber etc.
Temperature Control: -40℃~100℃
Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc. It can simulate the external environmental conditions in the climate chamber or replace the internal system, which can create the necessary actual temperature conditions for the test bench.
Temperature Control: -85℃~250℃
Suitable for semiconductor process wet washing, photolithography, etching, chemical meteorological deposition, physical meteorological deposition, and the electronics industry (photolithography process)