Bearing Industrial Freezer
GY -150℃~-20℃- Cooling Power @-110℃0.7kW~2kW
- Power range12kW~40kW
- Storage Capacity280l~1000L
- Temperature fluctuation±2℃
- Weight570KG~1250KG
- Place of OriginChina
Product data download
use in mechanical production workshop environments
Applied in ultra-low temperature testing of large-scale equipment
Compressor automatic cascading low temperature -150 ° C

Configuration Details
Model |
GX-6528N |
GX-6550N |
GX-6580N |
GY-6528N |
GY-6550N |
GY-6580N |
GY-65A16N |
Volume |
280L |
500L |
800L |
280L |
500L |
800L |
1600L |
Inner dimension cm |
61 |
80 |
100 |
80 |
120 |
135 |
200 |
Type |
(Vertical) |
(Chest/Horizontal) |
|||||
Capacibility carrying |
150KG |
220KG |
300KG |
150KG |
220KG |
300KG |
650KG |
Designed bearing capacity is two times of the standard one, (refrigeration system is designed according to the standard capacity when target artifact weight is greater than the standard capacity, the cooling rate will decrease) |
|||||||
Temp. range |
-65℃~60℃ |
-65℃~60℃ |
-65℃~60℃ |
-65℃~60℃ |
-65℃~60℃ |
-65℃~60℃ |
-65℃~60℃ |
Cooling capacity at -60℃ |
1kw |
1.5kw |
2.5kw |
1kw |
1.5kw |
2.5kw |
4kw |
Temp. accuracy |
±2℃ |
±2℃ |
±2℃ |
±2℃ |
±2℃ |
±2℃ |
±2℃ |
Heating power |
2kw |
3kw |
5kw |
2kw |
3kw |
5kw |
8kw |
Nickel-chromium alloy electric heating heater, the controller has double safety protection, with independent temperature limiter protection. |
|||||||
Cooling rate |
(ambient temperature of 25 degrees, no-load, from 60 degrees to -60 degrees about 1 hour).;cooling rate will be a little different for temperature changes. |
||||||
Controller |
PLC multifunctional controller |
||||||
Operation panel |
7-inch color touch screen, display set temperature, measured temperature. |
||||||
Temp. record |
Temperature curve and fault record, U-disk data export, excel format. |
||||||
Inside circulating air |
1650 m³/h |
2100 m³/h |
2750 m³/h |
2100 m³/h |
2750 m³/h |
3500 m³/h |
6000 m³/h |
When it is open, the internal circulation fan automatically turns off. The touchscreen displays open state. |
|||||||
Compressor |
Emerson Copeland, adopt cascade refrigeration technology |
||||||
Intermediate heat exchanger |
Plate heat exchanger |
||||||
Dry filter |
Emerson |
||||||
Expansion valve |
Electronic expansion valve |
||||||
Evaporator |
Copper-tube with aluminum-fin |
||||||
Cooling Type |
Air-cooled with water-cooled auxiliary functions (Ensure good cooling capacity when temp. above 30 degrees) |
||||||
Means of insulation |
Polyurethane foam insulation, thermal insulation layer 125 mm, with embedded FIR boards |
||||||
Safety Protection |
Self-diagnosis function; Phase sequence phase failure protection; leakage protector; cooling unit overload protection; high and low pressure switch, overload relay, thermal protection device, high temperature protection and temperature fault protection. |
||||||
Case material |
Outside is cold rolled steel painting, internal is SUS304 wire drawing board. |
||||||
Refrigerant |
R404A/R23 |
||||||
Dimension mm |
1150*1150* |
1350*1300* |
1550*1300* |
2200*1150* |
2700*1200* |
2900*1300* |
3700*1400* |
Power 380V 50HZ |
5.5KW MAX |
7.5KW MAX |
13.5KW MAX |
5.5KW MAX |
7.5KW MAX |
13.5KW MAX |
19KW MAX |
Weight |
380kg |
480kg |
650kg |
385kg |
485kg |
650kg |
780kg |
Optional |
High temperature reaches 150degree and temperature accuracy is ±0.5degree;the input power will be changed(When select this model, the thickness of thermal insulation layer will be 150mm,thermal insulation material will be silicate and vacuum plate) |
||||||
Optional |
Closed circulating oil heating system, no direct electric heating element inside the box, suitable for flammable products test |
||||||
Optional |
Temp. accuracy ±0.5℃ |
||||||
Optional |
Cooling and heating program controlled, meet cold treatment process requirements(can set 5 programs, each program can edit 40 steps.) |
||||||
Optional |
Interior door, reduce cooling capacity lost when picking small workpieces (temperature below 60 degrees optional) |
||||||
Optional |
Outside SUS304 wire drawing board case |
||||||
Optional |
Diameter 50mm cable hole |
||||||
Optional |
Electric heating vacuum glass observation window (with lighting) 200mm*300mm |
||||||
Optional |
Low temperature automatic defrost (can be once per hour or use manual button to defrost), ensure it can work at low temperature for long time even the door is open and close frequently) |
Product Description
If the low temperature refrigeration system has been frosted, believing that some enterprises have met, then how should we deal with such situation? Are there any methods can solve this problem. Today, let’s know something about it with Guanya refrigeration company.
1. First turn off the suction valve of the low temperature box compressor and unload to the minimum number of cylinders to operate.
2. Then close the liquid supply valve of the intermediate cooler and close the suction valve of the small high pressure cylinder.
3. After the high pressure cylinder is returned to normal, open the suction valve of the large and low pressure cylinder again. When the normal operation has been resumed, then supply the liquid to the intermediate cooler.
4. If the frosting of high pressure cylinder is severe, the operation of the unit must be stopped.
5. Drain the intermediate cooler.
6. The cooling water treatment is the same as the single-stage treatment.
Do you remember the above way of processing? If you still have some questions, please contact the customer service on the official website of Guanya refrigeration company immediately, and solve the problem in time!
Appearance
Depending on the on-site environment, you can choose to open the door upwards or sideways, with capacities ranging from 280 to 1600L.

Applications
Mainly used in industrial cold treatment, for cold shrinkage of copper sleeves, bearings, precision mechanical assembly, and ultra-low temperature testing.

You may also be interested in these products
Low Temperature Freezer GD series -150℃
Mainly used in industrial cold treatment, for cold shrinkage of copper sleeves, bearings, precision mechanical assembly, and ultra-low temperature testing. …
Ultra-low Temperature Freezer -80℃~-10℃
Applied in ultra-low temperature testing of large-scale equipment Depending on the on-site environment, you can choose to open the door upwards or sideways, with capacities ranging from 280 to…
Cryogenic Refrigerator -65℃~-10℃
Applied in ultra-low temperature testing of large-scale equipment Ultra-low temperature refrigerator is also known as cryopreservation box, cryogenic refrigerator, cryopreservation box and so on, the common low temp…
Industrial Refrigerator -100℃~-30℃
Ultra-low temperature refrigerator is also known as cryopreservation box, cryogenic refrigerator, cryopreservation box and so on, the common low temperature refrigerator of which is -65 ℃ ~ -10℃. The refrigeration syste…