Search the whole station


blog

About LNEYA product selection, advantages, and information about the chiller industry.

Cryogenic Refrigerator -65℃~-10℃
Cryogenic Refrigerator -65℃~-10℃
Cryogenic Refrigerator -65℃~-10℃
Cryogenic Refrigerator -65℃~-10℃

GX -65℃~-10℃

Upright industrial refrigerator or horizontal industrial refrigerator
  • Cooling Power @-60℃1kW~4kW
  • Power range5.5kW~19kW
  • Storage Capacity280l~1600L
  • Temperature fluctuation±2℃
  • RefrigerantR404A/R23
  • Weight380KG~780KG
  • Place of OriginChina

Suitable for use in mechanical production workshop environments

Cryogenic Refrigerator -65℃~-10℃ - freezer(images 5)

Configuration Details

Model GD-1100-B2-GYZ
GD-1100-B2-GYZW
GD-1100-C1-GYZ
GD-1100-C1-GYZW
GD-1100-C2-GYZ
GD-1100-C2-GYZW
GD-1100-D1-GYZ
GD-1100-D1-GYZW
GD-1100-E1-GYZ
GD-1100-E1-GYZW
Effective volume 1100L 1100L 1100L 1100L 1100L
Inner container size cm 90*100*125 90*100*125 90*100*125 90*100*125 90*100*125
Temperature range -65℃~-35℃ -80℃~-50℃ -100℃~-70℃ -120℃~-90℃ -150℃~-110℃
Control accuracy Within the controllable temperature range of ± 0.5 ℃
Bearing capacity 350kg Other load-bearing qualities can be customized
Cooling capacity No load, cool down to 25 degrees Celsius at room temperature (minimum temperature setting+10 ℃) for about 1 hour
Temp uniformity Within ± 2 ℃
Open mode Side opening door, double layered interior and exterior door design, opening the exterior door
automatically closes the circulating fan
Evaporator Electrophoretic copper tube with aluminum fins
Compressor Emerson Valley Wheel Vortex Compressor, Carlisle Semi Enclosed Piston Compressor
Controller Programmable PLC controller, 7-inch touch screen
Safety protection Having self diagnostic function; Refrigerator overload protection; Multiple safety protection functions such as high and low
pressure sensors, overload relays, and thermal protection devices; Pressure balanced design ensures smooth door opening
Data record Temperature curve recording, USB data export in Excel format, fault record
Defrosting function Can set timed defrosting function
Insulation layer 150mm 150mm 150mm 200mm 200mm
Polyurethane foam secondary foaming+FIR board
Refrigerant R404A R23 R404A R23 Mixed refrigerant 1 Mixed refrigerant 2 Mixed refrigerant 3
Material quality Inner liner SUS304 shell cold-rolled plate spray coated with RAL7035
Refrigeration
components
Famous brands are used for condenser, plate heat exchanger, oil separator, pressure sensor, temperature sensor,
drying filter, electronic expansion valve, gas-liquid separator, sight glass, frequency converter, etc
Dimension 120*235*170 120*235*170 120*235*170 130*250*180 130*250*180
Power supply   400V 50HZ
  Other sizes and load-bearing capacity can be customized

Product Description

Ultra-low temperature refrigerator is also known as cryopreservation box, cryogenic refrigerator, cryopreservation box and so on, the common low temperature refrigerator of which is -65 ℃ ~ -10℃.

The refrigeration system of ultra-low temperature refrigerator basically adopts the working principle of cascade refrigeration and is equipped with two fully enclosed compressors as high and low temperature compressor. The copper tube of the low-temperature evaporator is attached directly to the outside of the inner box in the form of a coil and with heat transfer cement block between the coil and the box wall of the gap, to increase the heat exchange effect. The condensing evaporator is a shell tube structure with four tubes of the thread-shaped copper tube and a countercurrent heat exchange.

The cryogenic stage system is equipped with a gas heat exchanger to make the low-pressure gas coming out of the evaporator heat exchange with the high-pressure gas before the condenser-evaporator, which not only reduces the heat load of the condensing evaporator but also makes full use of the heat.The wax removal filter is the most common, the main purpose of the filter is to remove the paraffin from the frozen oil in order to reduce the possibility of “oil plugging” in the system.

In addition, according to different applications, ultra-low temperature refrigerator can also be equipped with some accessories. For example, take temperature re
corder for a permanent record of operating parameters; use the carbon dioxide backup system for special circumstances to ensure the gas preservation environment to maintain a normal state and choose the voltage booster for guaranteeing the normal work of the compressor under low pressure.

Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

Expand more!