Wuxi Guanya Refrigeration Technology co., ltd

Heating and cooling cycle machine maintenance boot operation instructions

When users choose the heating and cooling cycle machine, they often have to choose the right conditions for their own work, and their knowledge of maintenance and start-up also needs our attention.

After the installation of the heating and cooling cycle machine, the pipeline cleaning and sewage discharge, pressure test leak detection, air release, cooling water and chilled water system trial operation shall be carried out. After all normal operation, the unit commissioning and operation, cooling water and freezing shall be started. The water should be treated with water. The high alkaline water quality will intensify the corrosion of the copper tube and reduce the service life of the heat exchanger. The pH of the system water should be in the range of 7.0 to 8.5.

Press the “SET” button on the heating and cooling cycle thermostat once, the display shows the current thermostat set value. At this time, press the up and down triangular arrow buttons on the thermostat to adjust the thermostat set value and adjust. After that, press the “SET” button to confirm the new thermostat setting. note. The freezing water temperature cannot be set too low. If the temperature is too low, the cooling efficiency of the unit will be lowered, and the low temperature protection action alarm may be stopped. The water temperature may be set to be slightly lower than the required temperature. Set the water temperature according to actual needs.

After the heating and cooling cycle machine is turned on, the unit is equipped with an index of observable high and low pressure gauges with high and low pressure gauges, and the unit is operating normally. The normal operating pressure of high pressure is 12-18 Kg/cm2. The low pressure is 3 to 6 kg/cm2. Start up should see if the steering of the fan is correct, such as forward rotation can be started, reverse rotation means that the power supply wiring is reversed, and the phase sequence must be replaced before starting. The setting values of various protection devices have been set up by the factory. Do not change it at will.

When the heating and cooling cycle unit has a fault alarm and stops, first press the stop button of the unit (the alarm light will go out), and then check the cause of the fault. Do not force the machine to run before the fault is eliminated. If it is not an emergency, the unit should not be turned off by cutting off the main power supply; if the unit is stopped for a long time in the winter, turn off the unit first, then turn off the main power supply, and drain the water in the system.

To keep the heating and cooling cycle machine clean and well ventilated, periodically clean and remove the condenser to ensure normal and stable operation of the unit. To keep the cooling tower clean, and to keep the air flowing around the tower, the temperature is low, to prevent debris from entering the cooling tower to reduce heat dissipation efficiency. Air-cooled type Please keep the surface of the cooling water machine heat-dissipating coil clean, ensure the surrounding air circulation, low temperature, regularly clean the scale on the coil to ensure good heat transfer. If the cooling water machine has been in use for more than six months, or if the high/low pressure switch is frequently malfunctioning or the cooling capacity is reduced, please arrange for the staff to clean the condenser. If the repair is repeated according to the above instructions, the alarm of the cooling water machine is still {长鸣}, then the staff should be arranged for repair.

LNEYA is a high-tech enterprise that produces and sells technology. It provides refrigeration and heating solutions for pharmaceutical chemical research users. Its heating and cooling cycle machine will provide certain after-sales service after leaving the factory.
Related News
  • 2020 CPhI China The 20th World Pharmaceutical Raw Materials China Exhibition

    2020 CPhI China The 20th World Pharmaceutical Raw Materials China Exhibition

    December 17, 2020December 16-18 Booth number: W5P08 Shanghai New International Expo Center (Pudong)view
  • 483Meet Your Dream Equipment for Distillate CBD Extraction

    483Meet Your Dream Equipment for Distillate CBD Extraction

    February 6, 2021If you need equipment to distill CBD, you need to scrutinize your choices, as the equipment can vary in its features and design. When you use equipment that produces a CBD distillate, you want to seek out a system made by a manufacturer that provides proven and reliable products. You should also work with a business that can train you on the use of the equipment you buy.view
  • Won the second place in the 2022

    Won the second place in the 2022

    December 5, 2022On November 18, 2022, it was sponsored by the Jiangsu Provincial Association for Science and Technology, the Provincial Taiwan Affairs Office, the Provincial Department of Industry and Information Tec...view
  • LNEYA won the title of Jiangsu Provincial Gazelle Enterprise in 2022

    LNEYA won the title of Jiangsu Provincial Gazelle Enterprise in 2022

    January 13, 2023Recently, the Jiangsu Provincial Productivity Promotion Center officially released the evaluation results of the unicorn enterprises and gazelle enterprises in 2022 in Jiangsu and the high-tech zone, ...view
  • Approaching LNEYA 5 Main Products

    Approaching LNEYA 5 Main Products

    January 11, 2018Industrial Chiller:Industrial Chiller varies from dynamic temp. Special Chiller:Special Chiller consist of Multi-reactor chiller (TCU).Environmental Chamber:The test object is connected to a testing adapter. Industrial Freezer:Industrial freezer consist oview
  • The Analysis Of Ultra Low Freezer'S Price

    The Analysis Of Ultra Low Freezer'S Price

    July 4, 2018What are the characteristics and functions of ultra low freezer: 1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the proce...view
Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • LT -45℃~30℃

    LT -45℃~30℃

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N;view
  • TES -45℃~250℃

    TES -45℃~250℃

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • TES  -85℃~200℃

    TES -85℃~200℃

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view