FL-WD 5℃~30℃
Evaporative condensation (dual compressors) chiller- Cooling Power60kW~427kW
- Power Supply3N/380V/50Hz
- Weight1320kG~6640kG
Product data download
- manual.pdf
Send us a message and we will contact you as soon as possible
Product Description
1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.
2.Due to continuous updating of product technology, the above data is subject to change without prior notice.
3.In addition to the listed product models, our company can customize non-standard units according to customer requirements.
Model FL-WD | 280 | 400 | 500 | 600 | 720 | 840 | 910 | 1008 | 1160 | 1260 | 1340 | 1420 | 1530 | 1700 | 1940 | |
Cooling capacity |
KW | 272 | 388 | 485 | 597 | 715 | 833 | 906 | 1008 | 1152 | 1268 | 1342 | 1416 | 1528 | 1700 | 1940 |
Kcal/hr *10³ |
234 | 394 | 417 | 513 | 615 | 716 | 779 | 867 | 991 | 1090 | 1154 | 1218 | 1314 | 1462 | 1668 | |
Power | 3N/380V/50Hz | |||||||||||||||
Cooling input power |
KW | 61 | 86 | 108 | 130 | 155 | 180 | 193 | 215 | 240 | 265 | 277 | 290 | 318 | 355 | 400 |
Compressor | Form | semi-closed double screw compressor | ||||||||||||||
Heat control range |
0-25-37.5-50-625-75-87.5-100(12.5% segmentation control) | |||||||||||||||
Chilled water |
Form | Dry, overflow or falling film heat exchanger | ||||||||||||||
Chilled water volume T/H |
47 | 67 | 83 | 102 | 123 | 143 | 155 | 173 | 197 | 217 | 230 | 243 | 262 | 291 | 333 | |
Water pressure drop KPa |
44 | 49 | 49 | 50 | 54 | 56 | 58 | 72 | 73 | 73 | 74 | 74 | 75 | 75 | 76 | |
Connection size |
DN-80 | DN-100 | DN-125 | DN-150 | DN-200 | |||||||||||
cooling water |
Form | horizontal and tube sheel type | ||||||||||||||
cooling water volume T/H |
57 | 81 | 100 | 123 | 148 | 172 | 187 | 208 | 237 | 260 | 275 | 289 | 315 | 351 | 396 | |
Water pressure drop KPa |
44 | 45 | 46 | 49 | 55 | 56 | 58 | 65 | 74 | 74 | 72 | 74 | 76 | 76 | 76 | |
Connection size |
DN-80 | DN-100 | 2-DN-80 | 2-DN-100 | 2-DN-125 | 2-DN-150 | ||||||||||
Security device |
High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc. |
|||||||||||||||
Refrigerant | Charge Kg |
34 | 53 | 68 | 84 | 99 | 121 | 134 | 149 | 165 | 188 | 199 | 205 | 219 | 235 | 250 |
Dimension | Length mm |
3200 | 3235 | 3250 | 3520 | 3810 | 3810 | 3810 | 3830 | 3890 | 3900 | 3900 | 3950 | 3970 | 4870 | 4870 |
Width mm |
945 | 1100 | 1100 | 1300 | 1300 | 1300 | 1300 | 1300 | 1500 | 1500 | 1500 | 1500 | 1500 | 1600 | 1600 | |
Height mm |
1400 | 1420 | 1610 | 1755 | 1950 | 1975 | 1985 | 2050 | 2185 | 2185 | 2200 | 2200 | 2200 | 2250 | 2250 | |
Unit weight |
Kg | 1650 | 2300 | 2400 | 3000 | 3500 | 3800 | 4000 | 4500 | 5700 | 6200 | 6300 | 6700 | 7200 | 7900 | 8300 |
Working weight |
Kg | 1900 | 2550 | 2700 | 3500 | 4000 | 4350 | 4600 | 5050 | 6300 | 6800 | 6900 | 7400 | 7900 | 8600 | 9000 |
You may also be interested in these products
Water Chiller LT 5℃~35℃
Cooling Power 1.8kW to 60kW Conventional chillers can only cool at room temperature
Mini Chiller FL-800
Cooling power 0.35kW~0.9kW Power range 0.6kW
LJ -45°C~ -10°C
Cooling capacity @-20℃ 12kW~360kW Power range 12kW~270kW
LN -60°C~ -10°C
Cooling capacity @-55℃ 6kW~180kW Power range 14kW~300kW
loading…
已经是到最后一篇内容了!