KRYCH -40℃~100℃
Temp Flow Control+Test ChamberEnvironmental Chamber Provides -45°C~100°C
Large observation window allows real-time observation of test conditions in the box and timely adjustments.
Product data download
Temperature control during testing of new energy vehicle components
Integrated system provides new energy power battery samples
High temperature, low temperature, flow and pressure control and other needs
Environmental chamber provides -45°C~100°C
Advantage
High heat exchange density
Small footprint
Ensure battery core temperature is low
Better uniformity
Effectively extend battery life
Improve reliability and security
Reduce maintenance costs
Parameter
Model | KRYCH-15W KRYCH-15 |
||
Temp Control | -40℃~135℃ Antifreeze | -45℃~100℃ Test chamber | |
Antifreeze flow control | 2L/min~20L/min ±0.2L/min | ||
Antifreeze pressure | Measure and display the inlet and outlet pressure and display the pressure on the touch screen | ||
Test chamber volume cm | 100*100*100 1m3 | ||
Heating Power | 7.5kW Antifreeze | 5kW Test chamber | |
Refrigeration capacity Antifreeze |
135℃ | 7.5kW | |
20℃ | 7.5kW | ||
0℃ | 7.5kW | ||
-20℃ | 4.5kW | ||
-30℃ | 2.5kW | ||
-35℃ | 1.8kW | ||
Refrigeration capacity Test chamber |
100℃ | 6kW | |
-20℃ | 3.5kW | ||
-40℃ | 1.2kW | ||
Antifreeze temp. control accuracy | ±0.3℃ | ||
High & low tempe chamber Tempe control | ±0.3℃ | ||
Circulating air inside the test chamber | 3500m3/h | ||
When the door is opened, the internal circulation fan automatically turns off, and the door-opening status is displayed on the touch screen. | |||
Controller | PLC controller, fuzzy PID control algorithm | ||
Letter of agreement | Ethernet interface TCP/IP protocol | ||
Device internal temperature feedback | Internal temperature of the equipment tank, condensation temperature of the refrigeration system, compressor suction temperature, cooling water temperature (for water cooling equipment) | ||
Heating | Refers to the maximum heating output power of the system (according to each model) The heater has triple protection and an independent temperature limiter to ensure the safety of the heating system The heating power of 15kW uses a voltage regulator, and the heating power output control adopts 4~20mA linear control. |
||
Cooling capacity | It refers to the ability to take away heat at different temperatures (under ideal conditions). Actual working conditions need to consider environmental heat dissipation. Please amplify appropriately and take insulation measures. | ||
High temperature cooling module | Can cool down module from high temperature 150℃ | ||
Circulation pump flow and pressure | Using LNEYA magnetic drive pump | ||
Source 380V50HZ | 23kW max | ||
Overall dimensions cm | 125*235*190 excluding protruding parts, air-cooled and water-cooled have the same dimensions | ||
Compressor | Emerson Copeland Scroll Flexible Compressor | ||
Evaporator | Plate heat exchanger | ||
Refrigeration accessories | Emerson/Danfoss brand filter dryers, oil separators, etc. | ||
Throttle method | Electronic expansion valve | ||
Operation panel | 7-inch color touch screen, temperature curve display\EXCEL data export | ||
Security | It has self-diagnosis function; phase sequence phase failure protector, refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. | ||
Refrigerant | R-404A/R507C | ||
Antifreeze interface is reserved inside the chamber | ZG3/4 and switch valve | ||
Water coooling W | Models with W are water-cooled | ||
Water cooled condenser | Casing heat exchanger | ||
Cooling water 32℃ | 6m³/H | ||
Shell material | Cold rolled plate spraying (standard color 7035) |
Specially developed for new energy vehicle battery packs
Suitable for hot and cold shock at various temperatures
It can provide antifreeze system for high-temperature and low-temperature tests for automobile battery packs, and can also be used as a refrigeration and heating system for hot and cold shock.
The double-layer high and low temperature chamber is used as a high and low temperature testing device for power battery samples. It is currently mainly used in the new energy battery industry. It can directly complete high and low temperature charge and discharge for battery cells, modules, and PACKs in the test chamber, or store high and low temperatures. Functions such as explosion-proof pressure relief and fire protection devices are added under the conditions when the battery fails to be tested.
Upper and lower double-layer box design
Antifreeze battery cooling system included
The two-box system operates completely independently
working principle
The variable frequency pump can adjust the circulating hydraulic pressure and flow rate to achieve high-precision control of the total range from 5% to 100%.
(The output pressure and flow rate of the circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the set output pressure can be automatically controlled by the variable frequency pump. This can reduce the power consumption of the pump.)
The refrigeration unit mainly includes refrigeration compressor, condenser, oil separator, intermediate heat exchanger, internal circulation fan of the box, dry filter, condenser, evaporator, throttling mechanism, expansion tank, electrical control, etc.
The liquid refrigerant in the evaporator of the unit exchanges with the circulating air inside the box. The temperature rises and changes from liquid to gas. It is sucked into the suction port of the compressor. The high-temperature and high-pressure refrigerant gas compressed by the compressor first passes through The oil separator separates the refrigeration oil carried during the compression process, and then enters the condenser. After exchanging heat with ambient air or cooling water, it changes from high-temperature and high-pressure gas to high-pressure and normal-temperature liquid. The high-pressure and normal-temperature refrigerant liquid passes through the dry filter and then is throttled and decompressed by the expansion valve, that is, it changes from high-pressure liquid to low-pressure liquid. Low-pressure liquid (lower boiling point) enters the evaporator of the unit, and the cooling energy is brought to the inside of the box through circulating air to achieve refrigeration.
Equipment details
Cabinet design
Display operation
Stable operation
The sales interface of the whole machine has strong adaptability, one is better than N units
recommend products
MD -75℃~225℃
INQUIRY Configuration Details Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature uniformity ±1℃ ±1℃ ±1℃ …
YQH 0℃~-75℃
Temperture accuracy ±0.1℃ Flow control 12~45/min
FLT-100℃~80℃ low temperature cascade
Temperture accuracy ±0.1℃ Flow control 12~45/min
FLTZ -30℃~40℃ Double frequency conversion series
Temperture accuracy ±0.1℃ Flow control 15~45/min 6bar max Power range 380V 3.5kW
loading…