Search the whole station


News CentER

Is R22 Refrigerant Still Available for Chillers

Recent Blogs

Catalog

Tag

air cooled chiller chiller Chiller Installation chillers Chiller Troubleshooting Cold Assembly Freezer cooling chiller cooling heating circulator cooling heating system cooling system Double-Layer Glass Reactor dynamic temperature control system freezer gas cooling chiller heating circulator industrial chiller industrial cooling industrial freezer industrial refrigerator jacket reactor low temperature chiller news pharmaceutical chiller process chiller reactor chiller reactor cooling reactor cooling heating reactor heating cooling reactor system refrigerated circulator refrigeration chiller screw chiller semiconductor chiller semiconductor test chiller sundi tcu temperature control test chamber thermostat ultra low temperature chiller vehicle test chiller water chiller water cooled chiller wtd

Contact Us
*
*
*
Submissions in progress….
Submission successful!
Submission failed! Please try again later
Email error!
Wrong phone number!

If your industry requires temperature control, you’ve undoubtedly heard of R22 refrigerant. Yes, it was once the most common refrigerant in chillers and air conditioning systems. However, with growing environmental awareness and the enactment of relevant environmental regulations, it has been gradually phased out worldwide.
 
If you still have R22 chillers in your workshop, you might be wondering: Can R22 still be used in chillers? How should it be maintained? What are some environmentally friendly alternatives to R22?

What is R22 refrigerant?


R22 refrigerant (HCFC-22) is a colorless, odorless gas. It has a high latent heat of vaporization and absorbs a large amount of heat during evaporation. Furthermore, it is not easily decomposed at normal operating temperatures and does not react with many common lubricants.
 
Therefore, since the 1970s, it has been widely used in chillers, central air conditioners, refrigerators, and industrial refrigeration equipment, becoming one of the most common refrigerants at the time.
 
However, R22 contains chlorine in its molecule, which means that if released into the atmosphere, it can damage the ozone layer. Moreover, its GWP is as high as 1810, significantly impacting the greenhouse effect. Therefore, it is listed as a controlled phase-out substance under the Montreal Protocol, and many countries and regions have banned and discontinued its use.

R22 Refrigerant in Chillers


From the 1990s to the early 2000s, R22 refrigerant was practically standard in refrigeration equipment. It powered a vast number of centrifugal, screw, and scroll chillers. It’s no exaggeration to say that at the time, R22 chillers were used in everything from central air conditioning in commercial office buildings to industrial refrigeration in the chemical and pharmaceutical industries. Of course, a key reason for this was the low price and plentiful supply of R22.

Is R22 refrigerant still available for chillers?


Can R22 refrigerant still be used in chillers today? Requirements vary by country and region. We will primarily examine the current status of R22 use in the United States, the European Union, and China.

United States

Effective January 1, 2020, the EPA completely banned the new production and import of R22. If your R22 chiller needs maintenance, only use recycled or reclaimed R22.

EU

The EU’s regulation of R22 refrigerant began in 2015. It mandates a complete ban on its use, requiring even your equipment to phase out R22 chillers.

China

Since 2020, China has banned the production of R22. However, some existing R22 equipment can continue to be used. Users will simply have to rely on recycling to obtain the refrigerant.
 
This means that newly produced R22 refrigerant is no longer permitted on the market in these countries and regions. Even if you need it, you can only purchase scarce inventory and recycled products.

Explore high-efficiency and energy-saving chiller solutions!

Challenges of R22 Chillers


If you’re still using R22 equipment, you may be facing the following challenges:

Rising Costs

Commodity prices are inevitably influenced by supply and demand. Since R22 refrigerant is no longer produced, purchasing channels have decreased, leaving you with only recyclers or those with inventory. When supply exceeds demand, prices rise. Consequently, you face higher operating costs than before.

Environmental Violations

In some countries and regions, not only is the use of R22 refrigerant banned, but the use of R22 equipment is also restricted. Even if your chiller is functioning perfectly, it’s just sitting there gathering dust.

Low Energy Efficiency

With the introduction of modern refrigerants like R134a, R410A, and R1234ze, chillers using these refrigerants have been found to be more energy efficient than R22 chillers.

Solutions for R22 Chillers


Given these restrictions on R22 chillers, what should you do if you own one?

Continue Using Your Old Chiller

If your region doesn’t have strict restrictions on the use of R22 equipment, you can continue using it for a short period of time by purchasing recycled R22. The reason for this is that you don’t know when these chillers will be phased out by environmental regulations.

Refrigerant Replacement

Although it’s an R22 chiller, its refrigeration cycle is compatible with many new refrigerants. This means you don’t have to spend money on a new unit; you only need to modify the system and change the refrigerant. So, what refrigerants can replace R22?
 
R410A is a refrigerant blend of R32 and R125 in a specific ratio. Its ODP (ozone depletion potential) is zero, making it harmless to the ozone layer. Its operating pressure is approximately 50% higher than R22, resulting in superior thermodynamic performance and higher cooling efficiency.
 
However, it requires a dedicated compressor and piping, making it a non-drop-in replacement for R22 systems. Furthermore, it must use POE oil, rather than the traditional mineral oil, as a lubricant.
 
R32 is a single refrigerant with zero ODP and a global warming potential (GWP) of approximately 675, making it more environmentally friendly than R410A. Although it is mildly flammable (A2L), its use is permitted under strict safety regulations.
 
R407C is a blend of R32, R125, and R134a. Its thermodynamic properties are similar to R22, allowing it to be used directly in existing R22 chillers with minimal modifications. Its zero ODP, ozone-safety, and continued regulatory approval in most countries make it a popular transitional replacement for R22.
 
R290 is a natural refrigerant with zero ODP and an extremely low GWP (approximately 3). It is highly energy-efficient and environmentally friendly. Due to its flammability, current regulations impose strict safety standards on its use, but its use is permitted in small, compliant refrigeration equipment.
 
Of course, refrigerant replacement requires comprehensive consideration of compressor and lubricant performance, as well as system sealing. This requires a professional assessment, not guesswork or trial and error.

Replacing the Entire Unit

In addition to the above methods, a simpler solution is to purchase a new chiller using an environmentally friendly refrigerant. This eliminates the need to worry about the equipment and refrigerant becoming obsolete in the long term. Furthermore, the system’s energy efficiency can be significantly improved.

Conclusion


R22 refrigerant has entered the phase-out phase in most countries and regions. While recycled refrigerant can still be used, it’s clearly not a long-term solution due to its high price and limited supply. For long-term projects, replacing a new environmentally friendly chiller is a wiser option.
 
LNEYA offers a variety of environmentally friendly refrigerant chillers, including screw and scroll types, and can tailor temperature control solutions to suit different operating conditions and regional environmental regulations.

FAQ

No, most countries have banned manufacturing or importing new chillers with R22. Only existing systems can be serviced with reclaimed R22.

R22 is expensive today due to scarcity, often several times the cost of modern alternatives.