GD -40℃~+100℃

Cooling capacity 1.8kW~15kW
Heating power 6kW~15kW
Medium temp accuracy ±1℃
Energy are consumed

LNEYA’s battery test chamber adopts a double-layer design for high and low temperature control. Currently,The temperature control range of antifreeze and chamber is -40℃~+100℃. The environmental chamber for battery testing can provide a temperature range of -45℃~+100℃. The flow rate control range of antifreeze is 1L/min~25L/min.C

-40°C

lowest

100°C

Highest


±1℃

Temperature control accuracy

Medium & Material

Model GD-9000-2-B1-KRYCH-4A15W GD-9000-2-B1-KRYCH-475W GD-9000-2-B1-KRYCH-4A10W GD-1000-B1-KRYCH-475
Antifreeze flow control 1L/min~40L/min   1L/min~25L/min   1L/min~25L/min   1L/min~10L/min  
±0.2L/min ±0.2L/min ±0.2L/min ±0.2L/min
Antifreeze pressure Measure and display the inlet and outlet pressure, as well as the pressure displayed on the touch screen
Heating power 15kW 14kW 7.5kW 14kW 10kW 14kW 7.5kW 6kW
Cooling capacity Antifreeze 135℃ 15kW 7.5kW 10KW 7.5kW
20°℃ 15kW 7.5kW 10KW 7.5kW
0℃ 15kW 7.5kW 10KW 7.5kW
-20℃ 10kW 4.5kW 6KW 4.5kW
-35℃ 4kW 1.8kW 2.5KW 1.8kW
Antifreeze temp control accuracy ±0.1℃
Temperature uniformity ≤±1℃(unloaded)
Cooling water 20 ℃ 25m³/H 20m³/H 20m³/H 7m³/H

Communication protocol
CAN/TCP/RS485

Circulating pump
Magnetic drive pump

Power supply
380V 50HZ

The key to ensuring high precision and high efficiency

Advantages of battery test chamber

Pipe material
The pipe material of the WTD industrial chiller heater unit is SUS304, which has stronger atmospheric corrosion resistance, oxidation resistance and heat resistance, bringing your chiller a longer service life and lower maintenance costs.
 
Floor space
The WTD recirculating chiller heater uses a plate heat exchanger with a compact structure and a small footprint, which is suitable for use in places with limited space. The bottom is equipped with 4 casters, which is convenient for you to move the position at any time according to your needs.
 
Core accessories
The accessories of the WTD industrial chiller heater are basically internationally renowned brands. For example, the compressor uses Secop, Emerson Copeland and French Tecumseh, etc.; the dry filter uses Danfoss; the contactor/circuit breaker uses Schneider.

The key to ensuring high precision and high efficiency

The variable frequency pump can adjust the circulating hydraulic pressure and flow rate to achieve high-precision control of the total range from 5% to 100%.

(The output pressure and flow rate of the circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the set output pressure can be automatically controlled by the variable frequency pump. This can reduce the power consumption of the pump.)

battery test chamber

Heating power 6KW~15KW

Temperature uniformity ±1℃

climatic test chamber

Cooling rate Carrying idler (+20~-40℃)5℃/min

thermal shock chamber

High temperature +60~+150℃

Temperature fluctuation ≤1℃

You can trust our portable chiller factory

We are a very powerful chiller supplier with our own factory and more than 20 years of experience in the field of temperature control

As a leader in refrigeration industry, LNEYA always attaches great importance to technological innovation. LNEYA has 90+ invention patents, and 20% of its 400+ employees are technicians. The production process adopts the Siemens PLM design platform to uniformly manage all data in the entire life cycle of the product from design, sales, production, after-sales to scrapping, to maximize the traceability of product quality.

Global service

Served more than 30,000 customers.
Exported to more than 20 countries.

Certification patents

Has obtained CE certification, SGS certification, ISO certification.

After-sales service

Provide comprehensive technical training.
With 24/7 solutions.

Professional team

Founded in 2010, with 15 years of industry experience.
20% of employees are technicians.

Quality control

Visual inspection.
Performance test.
Electrical safety test.

Yes, we use environmentally friendly refrigerants, which will not damage the ozone layer.

*
*
Submitting….
Submitted successfully!
Submission failed! Please try again later
Email error!
Phone error!