Get in touch with our Dual channel chiller experts
Can’t find a suitable chiller? Or don’t know how to choose a chiller? Contact us now to get chiller details and prices
Search the whole station
lowest
Highest
Temperature control accuracy
Contact LNEYA sales engineer for catalog or price.
Model | FLTZ-203W-2T | |
Pipeline | channel 1 | channel 2 |
Temperature range | -20℃~+90℃ | -20℃~+90℃ |
Cooling capacity | 4kW@-10℃ | 4kW@-10℃ |
Heating capacity | 2kW | 2kW |
Heat conducting medium flow rate | 20L/min@0.5MPa | 20L/min@0.5MPa |
Ambient temperature | 10~35℃ | 10~35℃ |
Ambient humidity | 30~70% | 30~70% |
Cooling water temperature | 15~20℃ | 15~20℃ |
Cooling water flow rate | 20L/min | 20L/min |
Model | FLTZ-406W/ETCU-015W | |
Pipeline | channel 1 | channel 2 |
Temperature range | -45℃~+40℃ | +10℃~+80℃ |
Cooling capacity | 11kW@-20℃ 5kW@-40℃ |
13kW@+10℃ |
Heating capacity | 2kW | 6kW |
Heat conducting medium flow rate | 17L/min@0.7MPa | 17L/min@0.7MPa |
Ambient temperature | 10~35℃ | 10~35℃ |
Ambient humidity | 30~70% | 30~70% |
Cooling water temperature | 15~20℃ | 15~20℃ |
Cooling water flow rate | 40L/min | 20L/min |
Model | FLTZ-203W/2T dual system | FLTZ-305W/2T dual system | FLTZ-406W/2T dual system | |||
Temperature range | -20℃~90℃ | -30℃~90℃ | -45℃~90℃ | |||
Temperature control accuracy | ±0.1℃ | |||||
Heat conducting medium flow rate | 15~45l/min 6bar max | |||||
Heating capacity | 2.5kW | 2.5kW | 2.5kW | 2.5kW | 3.5kW | 3.5kW |
Cooling capacity | 3kW at-15℃ | 3kW at-15℃ | 5kW at-15℃ | 5kW at-15℃ | 2.5kW at -35℃ | 2.5kW at -35℃ |
Internal circulation fluid volume | 5L | 5L | 8L | 8L | 8L | 8L |
Cooling water interface | 50L/min at20℃ | 600L/min at20℃ | 50L/min at20℃ |
There are 2 channels with the same/different specifications in one shell;
The temperature of two fluid channel systems can be controlled separately by one host;
A power supply system achieves temperature control for two channels.
By simultaneously controlling the variable frequency compressor, variable frequency fan, and electronic expansion valve, good temperature stability can still be maintained during thermal load fluctuations.
energy are consumed;
Compressor hot gas heating within 40 degrees;
3-point temperature control
Compared to two single channel units, it reduces the overall footprint and wiring
Can reduce and share internal components.
1.Independent temperature control
Each channel of the FLTZ dual channel chiller can achieve independent temperature control. You can set different temperature ranges, cooling and heating capacities, and heat transfer medium flow rates according to application needs.
2.Compact structure
The expansion tank, condenser, cooling water system, etc. can be shared in dual channels, making your process chiller more compact and occupying a smaller area.
Cooling capacity 6kW~40kW
Cooling water flow 1.5m³/h~9m³/h
Temp accuracy ±0.05℃
Cooling capacity 2kW~15kW
Cooling water flow 1.2m³/h~10.2m³/h
Temp accuracy ±0.05℃
Cooling capacity 1kW~8kW
Cooling water flow 1.5m³/h~8m³/h
Temp accuracy ±0.05℃
Cooling capacity 0.6kW~3kW
Cooling water flow 1.8m³/h~6m³/h
Temp accuracy ±0.05℃
Cooling capacity 1.5kW~3kW
Cooling water flow 50L/min~100L/min 2bar~7bar
Temp accuracy ±0.05℃
Why Choose LNEYA ?
Get in touch with our Dual channel chiller experts
Can’t find a suitable chiller? Or don’t know how to choose a chiller? Contact us now to get chiller details and prices
Contact LNEYA
Submit your request to us and we will contact you within 24 hours