Search the whole station

Nitrogen Chiller

LQ -110℃~-40℃

LQ series are applied to cool down non-corrosive gases without cooling. For example, by passing dry compressed air, nitrogen, argon, and other ambient temperature gases through the LQ series nitrogen chillers, the resulting gas can reach the required low temperature and supply the components or heat exchangers that need to be tested.

Nitrogen Chiller(images 1)
Nitrogen Chiller(images 2)
Airflow range: 15m³/h ~ 100m³/h
Nitrogen Chiller(images 3)
Withstanding a pressure of 20 bar
Nitrogen Chiller(images 4)
Temp accuracy ±0.3℃
Nitrogen Chiller(images 5)
Lowest temperature -40℃,-70℃,-110℃

According to your needs, our LQ series nitrogen chillers can utilize various cooling mediums, such as dry compressed air, nitrogen, argon, and other special gases. Different gases can achieve different low temperatures. According to the low temperature range that can be achieved by gases, Our gas chillers can be mainly classified into nitrogen chillers and air chillers, etc.

LQ series

-110°C

lowest

-40°C

Highest

±0.3°C

Temperature control accuracy


LQ 4015
4015W
4030
4030W
4060
4060W
40100
40100W
7515
7515W
7530
7530W
7560
7560W
75100
75100W
Gas flow 15m³/h 30m³/h 60m³/h 100m³/h 15m³/h 30m³/h 60m³/h 100m³/h
Lowest temperature  -40℃  -75℃
Air inlet&outlet size ZG3/8 ZG3/8 ZG1/2 DN50 ZG3/8 ZG3/8 ZG1/2 DN50
Dimension cm 540*670*1350 550*750*1550 650*850*1750 750*950*1850 540*670*1350 550*750*1550 650*850*1750 750*950*1750
Circuit breaker 10A 10A 10A 16A 10A 16A 16A 25A

Model A1015W A1030W A1060W A10100W
Gas flow 15m³/h 30m³/h 60m³/h 100m³/h
Lowest temperature -110℃ -110℃ -110℃ -110℃
Heat exchanger material SUS304 contains small amount of copper
Air inlet&outlet size ZG3/8 ZG1/2 ZG1 DN50
Dimension cm 750*950*1750 800*1200*1750 1000*1250*1850 1150*1500*1950

Control system

Programmable controller and module


Display and record

Programmable controller and module


Process temperature
control


The romte target temperature



LNEYA never disappoints users!

Advantages of Nitrogen Chiller

According to your needs, our LQ series gas chillers can utilize various cooling mediums, such as dry compressed air, nitrogen, argon, and other special gases. Different gases can achieve different low temperatures. According to the low temperature range that can be achieved by gases, Our gas chillers can be mainly classified into nitrogen chillers and air chillers, etc.

Nitrogen Chiller(images 6)
Nitrogen Chiller(images 7)
Nitrogen Chiller(images 8)
LNEYA never disappoints users!

Application of Nitrogen chiller

1.Semiconductor packaging and testing process
Simulation of low-temperature environments during the testing and production process of electronic chips and components, ensuring the performance stability of components at specific temperatures.

2.Pharmaceutical and Chemical Industry
Cooling of gas reactors, low-temperature solidification of chemical raw materials, and low-temperature environmental control in pharmaceutical processes.

3.Research and Testing
Aerospace, automotive components (such as batteries, motors) low-temperature testing, simulating extreme environments

Nitrogen Chiller(images 9)

LQ -110℃~-40℃
Nitrogen chillers

Gas flow 15m³/h~100m³/h
Circuit breaker 10A~25A
Lowest temperature -40℃/-75℃/-110℃

Nitrogen Chiller(images 10)

AES -120℃~225℃
Temperature forcing system

Temperature accuracy ±0.1℃
Air treatment capacity 10m³/h-30m³/h 5bar-7.6bar
Heating and cooling rate <10s

Nitrogen Chiller(images 11)

AET -75℃~250℃
Thermal test system

Temp range Gas outlet ± 0.1℃, remote process ± 0.5℃
Air handing 22m³/h~95m³/h
Heating and cooling rate <10s

Nitrogen Chiller(images 12)

AI -105℃~125℃
Air circulation chiller

Heating power 3.5KW
Cooling capacity 1KW~3.5KW
Temp accuracy ±0.05℃

Nitrogen Chiller(images 13)

DR series -7℃
Industrial gas dryer

Pressure range 0.65~1.0Mpa
Dew point temperature -70℃
Gas processing capacity 425L/Min~1750L/Min

You can trust our Nitrogen Chiller factory

Nitrogen Chiller(images 18)

Global service

Served more than 30,000 customers.
Exported to more than 20 countries.

Nitrogen Chiller(images 19)

Certification patents

Has obtained CE certification, SGS certification, ISO certification.

Nitrogen Chiller(images 20)

After-sales service

Provide comprehensive technical training.
With 24/7 solutions.

Nitrogen Chiller(images 21)

Professional team

Founded in 2010, with 15 years of industry experience.
20% of employees are technicians.

Nitrogen Chiller(images 22)

Quality control

Visual inspection.
Performance test.
Electrical safety test.

LQ series gas chiller is suitable for dry compressed air, nitrogen, argon and other non-corrosive gases. Strongly corrosive, flammable and explosive gases or gases containing particulates are not applicable.

*
*
Submitting….
Submitted successfully!
Submission failed! Please try again later
Email error!