Search the whole station

Cooling Circulation Unit

AI -105℃~+125℃ Temperature accuracy ±0.05℃

Widely used in high and low temperature testing of semiconductor equipment.Cold and heat source of electronic equipment at high temperature and low temperature.

Cooling Circulation Unit(images 1)
AI SERIES

-105°C

lowest

125°C

highly

550m³/h

Circulating air flow


Model AI-6535 
AI-6535W
AI-8035W AI-1055W
Temperature range -65℃~+125℃ -80℃~+125℃ -105℃~+125℃
Temperature feedback PT100
Heating power 3.5KW 3.5kW 3.5kW
Cooling
capacity
125℃ 3.5KW 3.5kW 3.5kW
50℃ 3.5kW 3.5kW 3.5kW
20℃ 3.5kW 3.5kw 3.5kw
0℃ 3.5kW 3.5kw 3.5kw
-20℃ 3kW 3.5kW 3.5kW
-40℃ 2.1KW 2.5kW 3.5kW
-60℃ 1KW 2.1kw 3kw
-75℃   1kw 2kw
-95     1KW
Inlet and outletair intertace DN125
Water-cooled 1200L/H  1.5bar~4bar 1600L/H 1.5bar~4bar 2600L/H 1.5bar~4bar
Dimension cm 55*100*175 55*100*175 70*100*175
Weight 280kg 300kg 360kg
LNEYA never disappoints users!

Advantages of Cooling Circulation Unit

1.Independent refrigeration circulating air units;
2.Can work continuously for a long time, automatic defrosting, defrosting process does not affect the storage temperature;
3.Modular design, easy replacement of spare machine (if there are 10 machines, as long as a standby unit can);
4.Solve frequent open and close doors, evaporating system frosting problems;Evaporation system defrosting process does not affect.
5.Construct a set of high and low temperature and constant greenhouse (according to the drawings provided, the box can be joined together like building blocks to connect the electricity and water and set the temperature to work).

Cooling Circulation Unit(images 2)

Cooling Circulation Unit(images 3)

LQ -110℃~-40℃
Nitrogen chillers

Gas flow 15m³/h~100m³/h
Circuit breaker 10A~25A
Lowest temperature -40℃/-75℃/-110℃

Cooling Circulation Unit(images 4)

AES -120℃~225℃
Temperature forcing system

Temperature accuracy ±0.1℃
Air treatment capacity 10m³/h-30m³/h 5bar-7.6bar
Heating and cooling rate <10s

Cooling Circulation Unit(images 5)

AET -75℃~250℃
Thermal test system

Temp range Gas outlet ± 0.1℃, remote process ± 0.5℃
Air handing 22m³/h~95m³/h
Heating and cooling rate <10s

Cooling Circulation Unit(images 6)

AI -105℃~125℃
Air circulation chiller

Heating power 3.5KW
Cooling capacity 1KW~3.5KW
Temp accuracy ±0.05℃

Cooling Circulation Unit(images 7)

DR series -7℃
Industrial gas dryer

Pressure range 0.65~1.0Mpa
Dew point temperature -70℃
Gas processing capacity 425L/Min~1750L/Min

You can trust our gas chiller factory

We are a very powerful chiller supplier with our own factory and more than 20 years of experience in the field of temperature control

With rich experience and worry-free pre-sales and after-sales services, customers can trust us to provide unparalleled help to maintain the optimal performance and service life of the chiller. This further promotes the overall success and efficiency of their operations.

Cooling Circulation Unit(images 12)

Global service

Served more than 30,000 customers.
Exported to more than 20 countries.

Cooling Circulation Unit(images 13)

Certification patents

Has obtained CE certification, SGS certification, ISO certification.

Cooling Circulation Unit(images 14)

After-sales service

Provide comprehensive technical training.
With 24/7 solutions.

Cooling Circulation Unit(images 15)

Professional team

Founded in 2010, with 15 years of industry experience.
20% of employees are technicians.

Cooling Circulation Unit(images 16)

Quality control

Visual inspection.
Performance test.
Electrical safety test.

*
*
Submitting….
Submitted successfully!
Submission failed! Please try again later
Email error!
Phone error!