LNEYA has rich experience in industry product research and development, providing dynamic temperature control systems, heating systems, CHILLER cold and hot dual-circuit temperature control units and other products to meet industry needs.
SUNDI Fixed Frequency Series
—temperature control accuracy can reach ±0.3℃
Dynamic temperature control system has high temperature control accuracy, intelligent temperature control, and a wide temperature control range, from -120℃ to +350℃, which is suitable for most companies’ constant temperature control needs.
SUNDI Variable Frequency Series
—Energy saving of more than 20%
Compared with the old model, the cooling and heating circulation system of SUNDI products adopts variable frequency control, which saves more than 20% energy, reduces noise by more than 5 decibels, and has a small starting current.
HR/HRT Series
—Cost-effective economic model
Temperature range: -45℃~250℃, with heating and cooling functions; power only supports 3.5kW~15kW, low-power and cost-effective cooling and heating system.
TCU Temp Control System
—Temp control of large-scale workshop production process
-120℃~+350℃, and the high power supports the use of amplified production level. It provides straight-through ZLF series and heat exchange SR series, supports non-standard customization and explosion-proof customization, and meets the temperature control needs of pilot and production.
TCS Large system
—Distributed temperature control system
The use of automatic control systems and computer control technology can enable scientific, effective and strict monitoring and control of the process operations and parameters of pharmaceutical production, and realize the continuity and automation of pharmaceutical production.
Cold & Hot Dual-circuit Chiller
—Used for 120℃ high temperature heating drying, and 25℃ cooling capture on the other side
Easily build a waste liquid recovery system consisting of (jacketed tank + condenser + negative pressure system) for waste liquid recovery sublimation temperature control, and 25℃ condensation and capturing on the other side. The overall energy efficiency is better than 4.5.
UST Series
—Media temp control accuracy ±0.5℃, material temp control accuracy ±1℃
The high-temperature cooling process is adopted to achieve a cooling range of 300℃~50℃; it is equipped with a heating and cooling integrated container with a large heat exchange area, a fast heating and cooling rate, and a relatively small demand for heat transfer oil; it can achieve continuous heating and cooling.
UC/LY Series
—+50℃~+170℃, only supports medium temp control accuracy ±0.5℃
The entire cycle is closed, there is no oil mist volatilization at high temperature, and the heat transfer oil will not be oxidized and browned; it has the function of correcting the internal circulation temperature probe PT100.