Model LC-WS | 100 | 140 | 180 | 200 | 260 | 310 | 340 | 410 | 470 | 510 | 620 | 710 | 750 | 830 | 930 | |
Cooling capacity-15℃ |
KW | 48 | 64 | 83 | 92 | 124 | 151 | 166 | 197 | 234 | 247 | 305 | 354 | 389 | 418 | 467 |
Kcal/hr *10³ |
41 | 55 | 71 | 79 | 107 | 130 | 143 | 169 | 201 | 212 | 263 | 304 | 335 | 360 | 401 | |
Cooling capacity -20℃ |
KW | 39 | 52 | 68 | 75 | 101 | 123 | 135 | 160 | 191 | 202 | 249 | 289 | 317 | 341 | 380 |
Kcal/hr *10³ |
34 | 45 | 59 | 65 | 87 | 106 | 116 | 138 | 164 | 174 | 214 | 249 | 273 | 293 | 327 | |
Power | 3N/380V/50HZ | |||||||||||||||
Cooling input power |
KW | 27 | 35 | 45 | 50 | 66 | 79 | 86 | 104 | 122 | 129 | 158 | 182 | 203 | 216 | 238 |
Compressor | Form | semi-closed double screw compressor | ||||||||||||||
Heat control range |
0~25~37.5~50~62.5~75~87.5~100(12.5% segmentation control) | |||||||||||||||
Chilled water |
Form | Dry, overflow or falling film heat exchanger | ||||||||||||||
Chilled water volume T/H |
18 | 23 | 27 | 33 | 42 | 51 | 60 | 67 | 79 | 87 | 101 | 113 | 128 | 146 | 160 | |
Water pressure drop KPa |
49 | 60 | 73 | |||||||||||||
Connection size |
DN65 | DN80 | DN100 | DN125 | DN150 | |||||||||||
cooling water |
Form | horizontal and tube sheel type | ||||||||||||||
cooling water volume T/H |
25 | 28 | 33 | 41 | 53 | 62 | 72 | 80 | 107 | 118 | 136 | 150 | 171 | 198 | 213 | |
Water pressure drop KPa |
45 | |||||||||||||||
Connection size |
DN65 | DN80 | DN100 | DN125 | DN150 | |||||||||||
Security device |
High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc. |
|||||||||||||||
Refrigerant | Charge Kg |
23 | 30 | 35 | 44 | 48 | 55 | 58 | 61 | 75 | 85 | 90 | 115 | 133 | 155 | 165 |
Dimension | Length mm |
2500 | 2585 | 2635 | 2635 | 3100 | 3130 | 3130 | 3135 | 3135 | 3135 | 3135 | 3275 | 3300 | 3300 | 3668 |
Width mm |
850 | 900 | 900 | 900 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |
Height mm |
1300 | 1335 | 1335 | 1428 | 1428 | 1570 | 1680 | 1776 | 1800 | 1800 | 2000 | 2020 | 2070 | 2100 | 2120 | |
Unit weight |
kg | 850 | 850 | 1050 | 1270 | 1430 | 1740 | 1850 | 2480 | 2600 | 2870 | 3200 | 3400 | 3600 | 3850 | 4345 |
Working weight |
kg | 900 | 900 | 1100 | 1420 | 1580 | 1890 | 2050 | 2580 | 2800 | 3120 | 3500 | 3700 | 3900 | 4150 | 4640 |