FLT 5℃~-40℃
Semiconductor temperature controlThe main application is to accurately control the temperature in the semiconductor production process and testing process.
The heating method is within 40°C and uses compressor hot gas to heat the concentrate.
The circulation system adopts a fully sealed design, and the circulation pump adopts a magnetic drive pump.
Ammonia testing and safety testing to ensure system safety, reliability and prosperity;
After 24 hours of continuous running of the copy machine
Product data download
Temperature control in semiconductor production and testing processes
Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates continuously for 24 hours
Ensure stable and reliable overall semiconductor process flow from front-end to back-end
Configuration Details
Model |
ETCU-005W |
ETCU-008W |
ETCU-015W |
ETCU-030W |
Temp Range |
Cooling Water Temp +5℃~90℃ ±0.3℃ |
|||
Cooling Water Temp |
7℃~30℃ Use Siemens/Honeywell regulating valve to control cooling water flow |
|||
Cooling Capacity |
5kw |
8kw |
15kw |
30kw |
Test conditions: At maximum circulation volume, the temperature difference between the temperature control temperature and the cooling water temperature is 15°C |
||||
Circulation pump flow |
7~20L/min 5bar |
7~20L/min 5bar |
15~40L/min 5bar |
20~60L/min 5bar |
Tank volume |
6L |
8L |
10L |
15L |
Size |
480*750*390 |
480*750*390 |
480*750*390 |
480*750*500 |
Power |
220V 50HZ/60hz 0.6kw |
220V 50HZ/60hz1.3kw |
220V 50HZ/60hz 1.6kw |
Product Description
The semiconductor temperature control device Chiller is mainly used for precise temperature control in semiconductor production and testing processes. Its products include fluid fluorinated liquid temperature control (minimum -100 degrees), rapid temperature change of gas cooling and heating, rapid temperature change chuck, low-temperature gas refrigeration machine (-120 degrees), direct cooling refrigeration unit (-150 degrees), etc. The company applies various algorithms (PID, feedforward PID, and model free self built tree algorithm) in the system to achieve fast response and high control accuracy.
The important information such as the exhaust and suction temperature (pressure), condensation temperature, cooling water temperature (pressure), inlet and outlet liquid (gas) temperature (pressure), electrical power, current and voltage of each component, and water tank level of the chiller are all comprehensively managed, monitored and recorded through sensors connected to the control system.
Application scenarios of temperature control in semiconductor process
chillers that control the processing temperature on the Fab equipments
Single channel air-cooled cooler, mainly designed for etching machines. It is used to provide independent temperature control for the chamber side walls.
Applications
recommend products
MD -75℃~225℃
INQUIRY Configuration Details Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature uniformity ±1℃ ±1℃ ±1℃ …
YQH 0℃~-75℃
Temperture accuracy ±0.1℃ Flow control 12~45/min
FLT-100℃~80℃ low temperature cascade
Temperture accuracy ±0.1℃ Flow control 12~45/min
FLTZ -30℃~40℃ Double frequency conversion series
Temperture accuracy ±0.1℃ Flow control 15~45/min 6bar max Power range 380V 3.5kW