Compressor Inspection And Routine Maintenance Of Small Water Cooled Chillers
When people are hungry, they have to eat, and when the machine is broken, of course, it has to be repaired. In daily use, small water cooled chiller requires regular maintenance and other operations. Today, I would like to share with you how to judge whether the compressors of small water cooled chillers are working properly and its daily maintenance methods.
1. Regularly check the operation status of the compressor equipment to check the exhaust gas temperature, especially when changing seasons. If the temperature difference is too large, it may affect the operation of the machine. If it is abnormally viewed in time, adjust the system condensation temperature and liquid supply status.
2. For small water cooled chiller equipment, it is also necessary to check the turbidity of the cooling water regularly and replace it if necessary.
3. Check whether the pump is working normally, check the running, dripping and leaking of the water supply system.
4. The refrigeration oil and filter of the chiller are replaced once every six months under normal conditions, depending on the usage.
Small water cooled chillers should be checked about the oil return of the compressor regularly in the later work, and keep it clean. When the oil level is reduced, it is necessary to replace the new oil in time to prevent the machine from being damaged due to poor lubrication.
Related recommendations
-
Pharmaceutical industry reactor supporting equipment high and low temperature thermostat
968The high and low temperature thermostat is a temperature control device used in the pharmaceutical industry to heat the reactor for different time periods. It is simple and convenient to operate, and can quickly improve the temperature rise and fa...
View details -
What are the functions of the controllers for semiconductor temperature control equipment?
816In the temperature control equipment of semiconductor components, each accessory has a different function. Due to the different functions, the function of the temperature control valve and controller of the semiconductor components of LNEYA is dif...
View details -
What are the system components of various distillation devices?
8521. A complete set of short-path distillation equipment: including short-path evaporator, heating system, feeding system, cooling system, vacuum system, material collection unit, etc.; 2. A complete set of thin film distillation equipment: includin...
View details -
Closed circulation cooling system debugging attention note
1124Closed circulation cooling system needs to pay attention to some common problems during commissioning. Do a good job in debugging work. LNEYA manufacturers remind users that only when they are ready to work can they be better debugged. The prepara...
View details