What are the functions of the controllers for semiconductor temperature control equipment?
In the temperature control equipment of semiconductor components, each accessory has a different function. Due to the different functions, the function of the temperature control valve and controller of the semiconductor components of LNEYA is different.
The temperature-controlled water pump of the semiconductor component is a tool for accelerating the flow of water to enhance the heat transfer effect of the water in the heat exchanger. The water flow switch of the semiconductor temperature control device is used for the control or interruption protection of the fluid flow in the pipeline. When the fluid flow reaches the set value, the switch automatically cuts off (or turns on) the circuit. The pressure controller is used for pressure control and pressure protection. The unit has low pressure and high pressure controllers to control the working range of the system’s pressure. When the system pressure reaches the set value, the switch automatically cuts off (or turns on) the circuit.
The differential pressure controller of the semiconductor temperature control device is used as a pressure difference control, and when the pressure difference reaches the set value, the switch automatically cuts off (or turns on) the circuit. The temperature controller is used for control or protection of the unit. When the temperature reaches the set value, the switch automatically cuts off (or turns on) the circuit. In our products, temperature control is often used to control the unit’s start and stop conditions. Some still require a temperature controller like antifreeze.
The semiconductor temperature control device is used to indicate the condition of the refrigerant in the liquid line in the refrigeration device, the water content in the refrigerant, the flow condition of the lubricating oil from the oil separator in the return line, and some sight glass belts. There is an indicator that indicates the water content in the refrigerant by changing its color. (green means dry and yellow means wet). The volume change of water caused by temperature changes, the expansion tank is used to store this part of the expansion water, the system is regulated and fixed, and the system can compensate part of the water.
The semiconductor temperature control device is a relatively new device, and the performance above is required to be higher to be more stable.
Related recommendations
-
Battery pack cooling water machine Chiller use precautions
764The battery pack cooling water machine Chiller is used for the new energy battery pack cooling system. The user needs to pay attention to avoid misuse during operation, which causes the battery pack cooling and circulating water machine Chiller to...
View details -
Vacuum coating high and low temperature circulation system operation method
1025In many current chemical experiments, the vacuum coating high and low temperature circulation system can be used, making the high and low temperature refrigeration heating system supporting the vacuum coating system, and the operation is more effi...
View details -
13p semi-closed air-cooled compression condensing unit failure warning instructions
963The 13p semi-closed air-cooled compression condensing unit is used in industrial cold processing. After using it for a long time, some problems will arise, Wuxi Guanya (LNEYA) reminds. There is usually a high-pressure alarm on the 13p semi-closed ...
View details -
How to Control Static Electricity in Ultra-Low Temperature Test Chamber?
798When using the ultra-low temperature test chamber, in order not to affect the quality of it, we need to better control static electricity. So how to control static electricity in Wuxi crown sub-cryogenic test chamber?Static electricity in the ultr...
View details