Compressor Inspection And Routine Maintenance Of Small Water Cooled Chillers
When people are hungry, they have to eat, and when the machine is broken, of course, it has to be repaired. In daily use, small water cooled chiller requires regular maintenance and other operations. Today, I would like to share with you how to judge whether the compressors of small water cooled chillers are working properly and its daily maintenance methods.
1. Regularly check the operation status of the compressor equipment to check the exhaust gas temperature, especially when changing seasons. If the temperature difference is too large, it may affect the operation of the machine. If it is abnormally viewed in time, adjust the system condensation temperature and liquid supply status.
2. For small water cooled chiller equipment, it is also necessary to check the turbidity of the cooling water regularly and replace it if necessary.
3. Check whether the pump is working normally, check the running, dripping and leaking of the water supply system.
4. The refrigeration oil and filter of the chiller are replaced once every six months under normal conditions, depending on the usage.
Small water cooled chillers should be checked about the oil return of the compressor regularly in the later work, and keep it clean. When the oil level is reduced, it is necessary to replace the new oil in time to prevent the machine from being damaged due to poor lubrication.
Related recommendations
-
What are the precautions when choosing an industrial chiller?
1224An industrial chiller is a refrigeration device that assembles a refrigerator, condenser, evaporator, expansion valve, control system, and switch box on a common base or frame. According to the heat removal method of the unit, it can be divided in...
View details -
How to choose a laboratory deionized water chiller?
1997Pure water usually refers to water that has been treated to remove impurities, ions, organic matter, etc. Common examples include distilled water, reverse osmosis water, and deionized water. Deionized water has low conductivity due to t...
View details -
Maintenance steps of slope heating and cooling cooling heating thermostat
1455The slope temperature rise and fall cooling heating thermostat is the center to clean dust, garbage, etc. To clean and change inspection, inspection can find problems, find the potential defects of the slope temperature rise and fall high and low...
View details -
Ultra-high temperature material cold and hot impact box refrigeration oil
1848The ultra-high temperature material impact test chamber test device has too much frozen oil in the evaporator, which can also cause insufficient cooling and cause slow cooling. The oil stored in the evaporator of the ultra-high temperature materia...