Industrial Chiller System SUNDI -25℃~300℃

Industrial Chiller System SUNDI -25℃~300℃

  • Industrial Chiller System SUNDI -25℃~300℃
  • Dynamic Temp Control Systems-2.jpg
  • Dynamic Temp Control Systems-1.jpg
Industrial Chiller System SUNDI -25℃~300℃


  • Product Description
  • System Introduce
  • Technical Parameter
-25℃~300℃
Use high temperature resistant low-temperature magnetic drive pump or a leak-free high and low-temperature shield-driven pump, reduce the risk of system leakage. At the same time, the system has the advantages of low noise and big traffic flow.

Model SUNDI
-225V
SUNDI
-225WV
SUNDI
-235V
SUNDI
-235WV
SUNDI
-255V
SUNDI
-255WV
SUNDI
-275V
SUNDI
-275WV
SUNDI
-2A10V
SUNDI
-2A10WV
SUNDI
-2A15V
SUNDI
-2A15WV
SUNDI
-2A25V
SUNDI
-2A25WV
SUNDI
-2A38WV
SUNDI
-2A60WV
SUNDI
-2A95WV
SUNDI
-2A130WV
SUNDI
-2A200WV
Temp. range -25℃~+300℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 42 steps.
Communication 
Portocol
MODBUS RTU Protocol, RS485 interface
Material temp.
 feedback
PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
Medium temp. 
acccuracy
±0.5℃ ±1℃
Material temp. 
accuracy
±1℃ ±1.5℃
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling 
capacity 
kW at
300℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
50℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
-5℃ 2 3 4.5 6.6 8 12 19 30 46 70 80 125
-20℃ 1 1.8 2.8 3.8 4.6 7 12 16 22 32 43 65
Circulation 
pump max
L/min bar
20 35 50 50 110 110 150 150 250 400 400 600
2 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Pump LNEYA magnetic drive pump German magnetic drive pump
Compressor Mitsubishi Emerson copeland vortex flexible Dorin seni-closed compressor
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid 
low level protection, high temperature protection and temperature fault protection.
Closed circulation 
system
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, 
pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size G1/2 G3/4 G3/4 G1 G1 G1 DN32 DN40 DN40 DN50 DN65 DN65
Water-cooled 
type W(@20℃)
600L/H
800L/H
1000L/H
1200L/H
1600L/H
2200L/H
6m³/H
10m³/H
14m³/H
20m³/H
28m³/H
36m³/H
Dimension
(water type)cm
45*85
*130
45*85
*130
55*95
*170
55*95
*170
70*100
*175
80*120
*185
100*150
*185
/ / / / /
Dimension
(air type)cm
45*85
*130
45*85
*130
45*85
*130
45*85
*130
55*95
*170
55*95
*170
80*120
*185
100*150
*185
100*150
*185
205*145
*205
245*145
*205
275*160
*225
Isolate size
(air type)cm
45*110
*130
45*110
*130
55*120
*170
55*120
*170
70*125
*175
80*145
*185
105*120
*185
100*150
*185
100*150
*185
205*145
*205
245*145
*205
275*160
*225
Positive pressure
(water type)cm
110*95
*195
110*95
*195
110*95
*195
110*95
*195
110*95
*195
135*145
*195
(135+60) 
*145*225
(135+60) 
*145*225
(185+60) 
*145*225
(185+100) 
*145*225
(185+100) 
*145*225
(185+150) 
*165*225
Weight kg 130 180 195 260 320 390 620 820 1100 1350 1680 2250
Power 380V 50HZ 4kW 6kW 8kW 11kW 14kW 21kW 34kW 52kW 79kW 123kW 165kW 260kW


Typical application of refrigeration heating temperature control system

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Advantages and functions of temperature control system of refrigeration

Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touch screen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.



Adopt full closed pipe design, adopt high efficiency plate heat exchanger, reduce the demand of heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorb the moisture and volatile.

Related Products
  • Direct-Cooled Ultra-Low Temperature Chiller -150℃

    Direct-Cooled Ultra-Low Temperature Chiller -150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 degrees, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temp. Test Chamber

    High-Low Temp. Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • High-Low Temp. Humidity Test Chamber

    High-Low Temp. Humidity Test Chamber