Wuxi Guanya Refrigeration Technology co., ltd
products
Contact
Tel: + 86 510 82303782
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province,China
code chat
Industrial Chiller Systems SUNDI -25℃ ~ 200℃

Industrial Chiller Systems SUNDI -25℃ ~ 200℃

  • Industrial Chiller Systems SUNDI -25℃ ~ 200℃
  • Dynamic Temp Control Systems-2.jpg
  • Dynamic Temp Control Systems-1.jpg
Industrial Chiller Systems SUNDI -25℃ ~ 200℃


  • Product Description
  • System Introduce
  • Technical Parameter
  • Knowledge Center

-25℃~200℃
Use high temperature resistant low-temperature magnetic drive pump or a leak-free high and low-temperature shield-driven pump, reduce the risk of system leakage. At the same time, the system has the advantages of low noise and big traffic flow.



Model SUNDI-
225
SUNDI-
225W
SUNDI-
235
SUNDI-
235W
SUNDI-
255
SUNDI-
255W
SUNDI-
275
SUNDI-
275W
SUNDI-
2A10
SUNDI-
2A10W
SUNDI-
2A15
SUNDI
-2A15W
SUNDI-
2A25
SUNDI-
2A25W
SUNDI-
2A38W
SUNDI-
2A60W
SUNDI-
2A95W
SUNDI-
2A130W
SUNDI-
2A200W
Temp. range -25℃~+200℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. 
difference
Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 42 steps.
Communication 
Portocol
MODBUS RTU Protocol, RS485 interface
Material temp. 
feedback
PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor)
Medium temp. 
acccuracy
±0.5℃ ±1℃
Material temp. 
accuracy
±1℃ ±1.5℃
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling 
capacity
 kW at
200℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
50℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
-5℃ 2 3 4.5 6.6 8 12 19 30 46 70 80 125
-20℃ 1 1.8 2.8 3.8 4.6 7 12 16 22 32 43 65
Circulation pump 
max  L/min bar
20 35 35 50 75 110 150 200 250 400 400 600
2 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Compressor Mitsubishi Emerson copeland vortex flexible Dorin seni-closed compressor
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid 
low level protection, high temperature protection and temperature fault protection.
Closed circulation 
system
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, 
pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A,optional: R448A/R125
Connection size G1/2 G3/4 G3/4 G1 G1 G1 DN32 DN40 DN40 DN50 DN65 DN65
Water-cooled type 
W(@20℃)
600L/H
800L/H
1000L/H
1200L/H
1600L/H
2200L/H
6m³/H
10m³/H
14m³/H
20m³/H
28m³/H
36m³/H
Dimension
(water type)cm
45*85
*130
45*85
*130
55*95
*170
55*95
*170
70*100
*175
80*120
*185
100*150
*185
/ / / / /
Dimension
(air type)cm
45*85
*130
45*85
*130
45*85
*130
45*85
*130
55*95
*170
55*95
*170
80*120
*185
100*150
*185
205*145
*205
205*145
*205
245*145
*2250
275*160
*225
Isolate size
(air type) cm
45*110
*130
45*110
*130
55*120
*170
55*120
*170
70*125
*175
80*145
*185
105*120
*185
105*120
*185
205*145
*205
205*145
*205
205*145
*205
275*160
*225
Positive pressure
(water type)cm
110*95
*195
110*95
*195
110*95
*195
110*95
*195
110*95
*195
135*145
*195
(135+60)
 *145*225
(135+60) 
*145*225
(185+60) 
*145*225
(185+100)
 *145*225
(185+100) 
*145*225
(185+150) 
*165*225
Weight kg 115 165 185 230 280 300 550 750 1000 1250 1580 2150
Power 380V 50HZ 4kW 6kW 8kW 11kW 14kW 21kW 34kW 52kW 79kW 123kW 165kW 260kW


Typical application of refrigeration heating temperature control system

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Advantages and functions of temperature control system of refrigeration

Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touchscreen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function have many advantages to using staff: because the only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.



Adopt full closed pipe design, adopt high-efficiency plate heat exchanger, reducing the demand for heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorbing the moisture and volatile.

Advantages and Maintainence of Industrial Chiller Units

Water chiller is widely used in plastic, electroplating, electronics, chemical industry, pharmacy, printing, food processing and other industries.

Cold water machine is commonly known as freezer, refrigerating machine, ice water machine, freezing water machine, cooling machine etc., because of its wide range of use. Today, we are going to give you a detailed explanation of the advantages of Industrial Chiller Systems SUNDI -25℃ ~ 200℃/300℃

Accurate temperature control ability
For industrial chiller system products, accurate temperature control ability is very important. For example, our industrial chiller uses imported microcomputer digital temperature controller. High quality of thermostat products not only helps accurate control, but also energy saving and environmental protection.

High heat exchange efficiency
According to Mr. Li meihua, the advantages of shell-tube condenser and evaporator in industrial chiller are simple, easy to maintain and highly efficient heat exchange. For example: "chuangshengtai" series products adopt the company's unique design of shell tube condenser, evaporator. Its heat transfer performance is 20% higher than that of ordinary products. Also it has the features of less loss of the cold quantities, easily returning oil. And the heat transfer pipe will not be frostbitten. Therefore, its comprehensive cost efficient is the best.
Related Products
  • Direct-Cooled Ultra-Low Temperature Chiller -150℃

    Direct-Cooled Ultra-Low Temperature Chiller -150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 degrees, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temp. Test Chamber

    High-Low Temp. Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • High-Low Temp. Humidity Test Chamber

    High-Low Temp. Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
Leave a Message Email Us

we will contact you within 24 hours.

  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province,China