Industrial Chiller Systems SUNDI -25℃ ~ 200℃

Industrial Chiller Systems SUNDI -25℃ ~ 200℃

  • Industrial Chiller Systems SUNDI -25℃ ~ 200℃
  • Dynamic Temp Control Systems-2.jpg
  • Dynamic Temp Control Systems-1.jpg
Industrial Chiller Systems SUNDI -25℃ ~ 200℃


  • Product Description
  • System Introduce
  • Technical Parameter
  • Knowledge Center

-25℃~200℃
Use high temperature resistant low-temperature magnetic drive pump or a leak-free high and low-temperature shield-driven pump, reduce the risk of system leakage. At the same time, the system has the advantages of low noise and big traffic flow.


type

Temp range℃

Heating  KW

Cooling capacity  KW  AT  ℃

Flow/pressure
L/min bar

Outside size

power
KW

200

100

50

20

-5

-20

SUNDI-225

-25~+200

2.5

2.5

2.5

2.5

2.5

2

1

20

2

400*600*1150

4kw

SUNDI-225W

-25~+200

2.5

2.5

2.5

2.5

2.5

2

1

20

2

400*600*1150

4kw

SUNDI-235

-25~+200

3.5

3.5

3.5

3.5

3.5

3

1.8

35

2

550*680*1450

6kw

SUNDI-235W

-25~+200

3.5

3.5

3.5

3.5

3.5

3

1.8

35

2

500*680*1250

6kw

SUNDI-255

-25~+200

5.5

5.5

5.5

5.5

5.5

4.5

2.8

35

2

550*680*1450

8kw

SUNDI-255W

-25~+200

5.5

5.5

5.5

5.5

5.5

4.5

2.8

35

2

550*680*1450

8kw

SUNDI-275

-25~+200

7.5

7.5

7.5

7.5

7.5

6.6

3.8

50

2

550*680*1450

11kw

SUNDI-275W

-25~+200

7.5

7.5

7.5

7.5

7.5

6.6

3.8

50

2

550*680*1450

11kw

SUNDI-2A10

-25~+200

10

10

10

10

10

8

4.6

110

2.5

650*700*1750

14kw

SUNDI-2A10W

-25~+200

10

10

10

10

10

8

4.6

110

2.5

550*680*1450

14kw

SUNDI-2A15

-25~+200

15

15

15

15

15

12

7

110

2.5

750*800*1850

21kw

SUNDI-2A15W

-25~+200

15

15

15

15

15

12

7

110

2.5

650*700*1750

21kw

SUNDI-2A25

-25~+200

25

25

25

25

25

19

12

150

2.5

1250*1000*2050

34kw

SUNDI-2A25W

-25~+200

25

25

25

25

25

19

12

150

2.5

1000*950*1750

34kw

SUNDI-2A38W

-25~+200

38

38

38

38

38

30

16

200

2.5

1000*950*1750

52kw

SUNDI-2A60W

-25~+200

60

60

60

60

60

46

22

250

2.5

1500*1250*2050

79kw

SUNDI-2A95W

-25~+200

95

95

95

95

95

70

32

400

2.5

2050*1450*2050

123kw

SUNDI-2A130W

-25~+200

130

130

130

130

130

80

43

400

2.5

2050*1450*2050

165kw

SUNDI-2A200W

-25~+200

200

200

200

200

200

125

65

600

3

2750*1600*2250

260kw


Typical application of refrigeration heating temperature control system

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Advantages and functions of temperature control system of refrigeration

Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touchscreen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function have many advantages to using staff: because the only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.



Adopt full closed pipe design, adopt high-efficiency plate heat exchanger, reducing the demand for heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorbing the moisture and volatile.

Type

SUNDI/UST series

Control Mode

Feedback PID + Our special dynamic control calculation, Lneya PLC controller

Temp.control

Material reaction temp.control mode and jacket temp.control mode

Program Editor

10 programs, each program can edit 45 steps.

Communication Portocol

MODBUS RTU Protocol,RS485 interface

Optional  Ethernet interface/R232 interface

Temp.feedback

The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor

Material temp. feedback

Material temp. feedback:PT100 or 4~20mA or communication given

Temp.feedback:PT100

Temp. difference

Set or control oil outlet temp and reactor material temp. difference

Set or control equipment liquid inlet temp. And liquid outlet temp. Difference( keep system safe)

Material temp.accuracy

±1℃ (sometimes ±0.5℃)

Thermal medium temp. accuracy

±0.5℃

Closed circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.

heating

 Heating max output power

 The heater has triple protection and independent temperature limiter to ensure the safety of heating system.

The power is greater than 15KW with a voltage regulator, and the heating power output control adopts 4-20ma linear control.

Cooling capacity

The power of taking away the heat at different temperature

Circulation flow rate and pressure

  Lower than 75L/min, use Lneya Magnetic pump

Higher than 75L/min use Ultra wide temperature high energy efficiency centrifugal pump.

  Pressure selection: 2bar 3bar 5bar 8bar(small power equipment can not customize)

 The greater the pressure, the greater the power of the motor, which will increase the system load and reduce the cooling capacity of the system.

compressor

Different type different brand compress

Mitsubishi, skop, Emerson, Danfoss, Italy Dorin, German blog, bizell, French Tecumseh.

evaporator

KAORI Plate heat exchanger

Oil separator

Emerson/Lneya

Drying filter

danfoss/Emerson

Shock tube

CASTEL/packless

voltage-controlled

danfoss/Emerson/fengsheng

Expansion valve

Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.

Select different expansion valves with different temperature and cooling capacity.

Operation panel

Lneya 7-inch touch screen,show temp curve\EXCEL data output

Optional Siemens explosion - proof touch screen.(Place the operation panel outside the site area.)

optional GMP, FDA operation and record module (operator use record, data record, alarm record, etc.)

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.

refrigerant

R-404A / R404A R23 mixture/ R404A R23 R14 mixture

interface size

G1/2、G3/4、G1、DN25 DN32 DN40 DN50 DN65 DN80 DN100(PN10 RF)

Water-cooling W

 With W is water cooled type, lower than -60 degree equipment, you need use 7-25 degree cooled water

Water cooled condenser.

Tube heat exchanger, plate heat exchanger, tube condenser.

packless、sheng、KAORI、JINDIAN、XIAOLING etc

power

AC 380V 50HZ Three-phase five-wire system.  Small power 220V 50HZ single phase

Optional 460V 60HZ、220V 60HZ three-phase  

Shell material

Standard shellSUS 304,optional spraying plastics (color 7035)

Isolation of explosion-proof

optioanl(EXdIIBT4)   

Lneya explosion-proof product installation license number.:PCEC-2017-B025

Positive pressure explosion-proof

optioanl(EXPXdmbIICT4) The positive pressure system must be water-cooled type

Lneya explosion-proof product installation license number:PCEC-2017-B025

Self pressurizing system

Optional self-pressurized 3bar system, the temperature of the system can be expanded, the expansion tank is normal pressure.

KDOC-80 can be used in a pressurized system with a maximum temperature of 250 degrees (-85 degree ~ 250 degree).

KDOC-220 can be used in the self-pressurized system with maximum temperature to 320 degrees (-50 degree ~ 320 degree).

KDOC-210 can be used in a self-pressurized system with a maximum temperature of 300 degrees (-70 degree ~ 300 degree)

Flow/pressure

Optional flow/pressure sensor, display flow and pressure on the touch screen.

Optional control flow/pressure.


One for two system

Optional one for two systems: the costis lower than one to one system.

One unit heating and cooling machine contains two circulation system, two cooling system, two heating systems, one expansion system, one electrical system.

High exothermic control

Customizable high heat control system algorithm and components.

flow reactor temperature control module.

It can be used in the flow reactor temp control system (pump, internal circulation system, control algorithm, refrigeration)

Advantages and Maintainence of Industrial Chiller Units

Water chiller is widely used in plastic, electroplating, electronics, chemical industry, pharmacy, printing, food processing and other industries.

Cold water machine is commonly known as freezer, refrigerating machine, ice water machine, freezing water machine, cooling machine etc., because of its wide range of use. Today, we are going to give you a detailed explanation of the advantages of Industrial Chiller Systems SUNDI -25℃ ~ 200℃/300℃

Accurate temperature control ability
For industrial chiller system products, accurate temperature control ability is very important. For example, our industrial chiller uses imported microcomputer digital temperature controller. High quality of thermostat products not only helps accurate control, but also energy saving and environmental protection.

High heat exchange efficiency
According to Mr. Li meihua, the advantages of shell-tube condenser and evaporator in industrial chiller are simple, easy to maintain and highly efficient heat exchange. For example: "chuangshengtai" series products adopt the company's unique design of shell tube condenser, evaporator. Its heat transfer performance is 20% higher than that of ordinary products. Also it has the features of less loss of the cold quantities, easily returning oil. And the heat transfer pipe will not be frostbitten. Therefore, its comprehensive cost efficient is the best.
Related Products
  • LC-ZS -25℃~5℃

    LC-ZS -25℃~5℃

    August 27, 2018Specification:1.The standard design conditions are: chilled water:outlet water temperature -20 ° C, return water temperature -15 ° C; condensing temperature 40 ° C.2.Refrigerant is R404A.3.Due to c...view
  • Circulation Air Temp. Control System

    Circulation Air Temp. Control System

    March 30, 2018ModelAI-635WAI-655WAI-6A10WAI-835WAI-805WAI-810WRecirculating air temperature range ℃-65℃~125℃-65℃~125℃-65℃~125℃-85℃~125℃-85℃~125℃-85℃~125℃Control modePID adaptive controllerCommunication...view
  • Cryogenic Refrigeration System -150℃~-20℃

    Cryogenic Refrigeration System -150℃~-20℃

    January 11, 2018InformationIndustrial cryogenic treatment box Industry refrigerator Industrial freezer Industrial cryogenic box Cold treatment enclosure Metal cold treatment box Industrial cooling chest Cold treatment refrigerator Cold treatment freezer Refrigeration treview
Leave a Message Email Us

we will contact you within 24 hours.

  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu, China