Industrial Air Chillers SUNDI -45℃ ~ 250℃

Industrial Air Chillers SUNDI -45℃ ~ 250℃

  • Industrial Air Chillers SUNDI -45℃ ~ 250℃
  • Dynamic Temp Control Systems-2.jpg
  • Dynamic Temp Control Systems-1.jpg
Industrial Air Chillers SUNDI -45℃ ~ 250℃


  • Product Description
  • System Introduce
  • Technical Parameter
  • Knowledge Center

-45℃~250℃
In comparison to other thermal control systems, Dynamic Temperature Control systems differ sometimes considerably in their thermodynamic characteristics. In practice, Dynamic Temperature Control systems offer definite advantages in your work: noticeably shorter heating and cooling times, better stability and reproducibility through the entire process chain, greater safety for expensive glass reactors and the contained substances, together with the simple and easy operation.




Model SUNDI
-525
SUNDI
-525W
SUNDI
-535
SUNDI
-535W
SUNDI
-555
SUNDI
-555W
SUNDI
-575
SUNDI
-575W
SUNDI
-5A10
SUNDI
-5A10W
SUNDI
-5A15
SUNDI
-5A15W
SUNDI
-4A25
SUNDI
-4A25W
SUNDI
-4A38W
SUNDI
-4A60W
SUNDI
-4A95W
SUNDI
-4A130W
SUNDI
-4A200W
Temp. range -45℃~+250℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 42 steps.
Communication 
Portocol
MODBUS RTU Protocol, RS485 interface
Material temp. 
feedback
PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor)
Medium temp. 
acccuracy
±0.5℃ ±1℃
Material temp. 
accuracy
±1℃ ±1.5℃
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling 
capacity
 kW at
250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
0℃ 1.8 3 5 7 10 15 25 38 60 95 130 200
-20℃ 0.85 1.5 2.9 4.2 6 11 16 26 34 50 70 120
-40℃ 0.25 0.45 0.9 1.5 2 3.8 4.7 9 12 18 24 43
Circulation pump 
max
L/min bar
20 35 50 50 110 110 150 200 250 400 400 600
2 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Pump LNEYA magnetic drive pump German magnetic drive pump
Compressor Emerson, Danfoss, Italy Dorin,French Tecumseh.
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level
 protection, high temperature protection and temperature fault protection.
Closed circulation 
system
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure
do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size G3/4 G3/4 G3/4 G3/4 G1 G1 DN32 DN40 DN50 DN50 DN65 DN65
Water-cooled type 
W(@20℃)
600L/H
800L/H
1500L/H
1800L/H
2600L/H
3200L/H
7m³/H
12m³/H
17m³/H
24m³/H
32m³/H
42m³/H
Dimension
(water type)cm
45*85
*130
45*85
*130
55*95
*170
55*95
*170
70*100
*175
80*120
*185
100*150
*185
/ / / / /
Dimension
(air type)cm
45*85
*130
45*85
*130
45*85
*130
45*85
*130
55*95
*170
55*95
*170
80*120
*185
100*150
*185
205*145
*205
205*145
*205
245*145
*205
300*160
*225
Isolate size
(air type) cm
45*110
*130
45*110
*130
55*120
*170
55*120
*170
70*125
*175
80*145
*185
105*120
*185
100*175
*185
205*145
*205
205*145
*205
245*145
*205
300*160
*225
Positive pressure
(water type)cm
110*95
*195
110*95
*195
110*95
*195
110*95
*195
110*95
*195
135*145
*195
(135+60)
*145*225
(135+60)
*145*225
(185+60) 
*145*225
(185+100)
*145*225
(185+100)
*145*225
(185+150)
*165*225
Weight kg 130 180 195 260 320 390 620 820 1100 1350 1680 2250
Power 380V 50HZ 4.5kW 6.5kW 9kW 11.5kW 16kW 23kW 36kW 55kW 89kW 135kW 180kW 280kW

Typical application of refrigeration heating temperature control system

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Advantages and functions of temperature control system of refrigeration

Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touch screen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.


Adopt full closed pipe design, adopt high-efficiency plate heat exchanger, reducing the demand for heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorbing the moisture and volatile.

Operating Principle of Industrial Air Chillers

Industrial air cooler is a heat exchanger which USES air to cool the hot fluid. The hot fluid in the tube is heated through the exchange of heat between the tube wall, the fin and the outside air, which is usually supplied by the ventilator. Our Industrial Air Chillers SUNDI -45℃ ~ 250℃ can be applied to cooling and condensation such as

condensation of the top steam of oil refining and petrochemical industry, reflux oil, cooling of tower bottom oil, the cooling of various reaction products, cooling of circulating gas and condensing of steam turbine exhaust. Its working pressure can reach 69 mpa. However, the power consumption, noise, and floor area are large, and the cooling effect is greatly affected by climate change.

In order to avoid the heat medium affect the performance of medium because of long-term overheating, and to facilitate the storage or transportation, and to condense and distillate, we need to exchange heat of the medium. Usually, heat exchange equipment should be used to achieve the purpose of exporting, exchanging and cooling. When air is used as one kind of medium, this equipment is called air cooler.

Air cooler is widely used in petroleum, chemical industry, metallurgy and other industries as well as in the process industry.

Due to the low heat transfer coefficient of air and the high heat transfer coefficient of tube heat medium, their difference reaches several number grades, so we often use high fin in air cooler, close distance of double metal finned tube as the main heat transfer element. Heat through efficient heat exchange tube of the heat transfer medium is passed to the air which after accepting the heat temperature rises, at this time, the heat medium temperature drops, the air temperature rises, the hot air is directly emitted to the atmosphere to achieve the goal of decreasing the heat medium temperature.

Related Products
  • Direct-Cooled Ultra-Low Temperature Chiller -150℃

    Direct-Cooled Ultra-Low Temperature Chiller -150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 degrees, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temp. Test Chamber

    High-Low Temp. Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • High-Low Temp. Humidity Test Chamber

    High-Low Temp. Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
Leave a Message Email Us

we will contact you within 24 hours.

  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province,China