Dynamic temprature control system
  • Heating Power3.5kW~200kW
  • Cooling capacity0.45kW~200kW
  • Power range6.5kW~280kW
  • Medium accuracy±0.5℃~±1℃
  • Material accuracy±1℃~±1.5℃
  • RefrigerantR404A/R507C
  • Weight180KG~2250KG

Product data download

Product Description

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Configuration Details

Model SUNDI-535
SUNDI-535W
SUNDI-555
SUNDI-555W
SUNDI-575
SUNDI-575W
SUNDI-5A10
SUNDI-5A10W
SUNDI-5A15
SUNDI-5A15W
SUNDI-4A25
SUNDI-4A25W
SUNDI-4A38W SUNDI-4A60W SUNDI-4A95W SUNDI-4A130W SUNDI-4A200W
Temp. range -45℃~+250℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling capacity kW at 250℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  100℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  20℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  0℃ 3 5 7 10 15 25 38 60 95 130 200
  -20℃ 1.5 2.9 4.2 6 11 16 26 34 50 70 120
  -40℃ 0.45 0.9 1.5 2 3.8 4.7 9 12 18 24 43
Circulation pump max
L/min bar
35 35 50 60 110 150 200 250 400 400 600
    1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5
Pump Magnetic drive pump Magnetic drive pump
Compressor Emerson, Danfoss, Italy Dorin,French Tecumseh.
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1 DN32 PN10 DN50 PN10 DN50 PN10 DN65 PN10 DN65 PN10 DN65 PN10
Water-cooled type W(cooling water@20℃) 1200L/H
1.5bar~4bar
1500L/H
1.5bar~4bar
1800L/H
1.5bar~4bar
2600L/H
1.5bar~4bar
3200L/H
1.5bar~4bar
7m³/H
1.5bar~4bar
10m³/H
1.5bar~4bar
15m³/H
1.5bar~4bar
20m³/H
1.5bar~4bar
32m³/H
1.5bar~4bar
42m³/H
1.5bar~4bar
Dimension cm 45*70*160 55*70*175 55*70*175 65*85*185 70*85*185 80*120*185 150*100*185 200*145*205 200-145-205 250-145-225 300*160*225
Weight kg 180 195 260 320 390 620 820 1100 1350 1680 2250
Power 380V 50HZ 6.2kW 9kW 11.5kW 16kW 23kW 37kW 55kW 85kW 130kW 178kW 280kW

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Displays Various Information:

1. Displays all the kind of process control temperatures.
2. Shows the liquid level of the heat conducting medium in the expansion vessel.
3. Shows indication for refrigeration system working.
4. Shows indication for heater working.
5. Shows indication for circulation pump working.
6. Displays the temp. control ( materials temp. control pattern, heat conducting medium temp. control ).
7. The temp. upper limit, lower limit control can be set.
8. The temp. difference between jacket & reactor material can be set.
9. Shows the alarm to add the liquid when it is empty.
10. The refrigeration compressor can be set to operate manuallyor automatically.

Click online message to inquire about product details