UC +50℃~170℃
Can temperature control reaction material- Heating Power3kW~38kW
- Cooling power0.6kW~38kW
- Power range2.2kW~39.5kW
- Temperture accuracy±0.5℃
- Weight30kG~380kG
Product data download
It is suitable for the needs of various process production and experimental use in pharmaceutical and chemical enterprises. It can realize high temperature cooling process, directly cooling from high temperature of 300 degrees to 50 degrees. Equipped with a heating and cooling integrated container, the heat exchange area is large, the heating and cooling rate is fast, and the demand for heat transfer oil is small. The entire cycle of the product is closed, there is no oil mist volatilization at high temperature, and the heat transfer oil will not be oxidized and browned; it has the function of correcting the internal cycle temperature probe PT100, and has self-diagnosis and intelligent safety alarm. The equipment is equipped with a variety of safety protection functions such as high-voltage pressure switches, overload relays, and thermal protection devices to ensure the safety of your experiments and production.
Parameters Detailed
Model | LY-5020 | LY-A020 | UC-5020 | UC-A1020 | UC-A1520 | |||||
Temperature range | 50℃~200℃ | |||||||||
Controller | PID adaptive controller | |||||||||
Temp. control optional | Heat-conducting medium outlet temp. control | |||||||||
Communication protocol | MODBUS RTU protocol RS 485 interface | |||||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | |||||||||
Temp. accuracy | ±0.5℃ | |||||||||
Heating power | 5.5kw | 10kw | 5.5kw | 10kw | 15kw | |||||
Cooling capacity | 200℃ | 5.5kw | 10kw | 15kw | ||||||
100℃ | 4kw | 8KW | 12kw | |||||||
65℃ | 1.8kw | 3.4KW | 5kw | |||||||
Circulation pump | Max35L/min2BAR | Max50L/min2BAR | Max35L/min 2BAR |
Max50L/min 2BAR |
Max50L/min 2BAR |
|||||
Heater | Flanged pipe electric heater | |||||||||
Independent temperature limiter | Lneya | |||||||||
Cooler | Plate heat exchanger/Tube heat exchanger | |||||||||
Operation panel | Display set temperature and measured temperature,key operation input temperature | |||||||||
Sefety protection | Self-diagnostics;high pressure switch,overload relay、variety of security features such as thermal protection devices | |||||||||
Closed circulation system | The entire system is a fully enclosed system,no oil mist at high temperatures、low temperature does not absorb moisture in the air,the system does not increase the pressure due to high temperature during operation,the low temperature automatically replenishes the heat transfer medium | |||||||||
Connection size | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | |||||
Dimensions cm | 45*65*120 | 45*65*120 | 45*65*120 | 55*68*145 | 70*100*175 | |||||
Weight | 70kg | 80kg | 78kg | 128kg | 170kg | |||||
Power | AC 380V 50HZ | AC 380V 50HZ | AC 380V 50HZ | AC 380V 50HZ | AC 380V 50HZ | |||||
5.9kW (max) | 10.8kW (max) | 5.9kW (max) | 10.8kW (max) | 15.7kW (max) | ||||||
Case material | Cold rolled sheet spray | |||||||||
Optional | Optional 7-inch color touch screen,recording temperature curve,data export using excel format | |||||||||
Optional | SUS304 shell | |||||||||
Optional power | 220V 60HZ three phase,440V~460V 60HZ three phase |
You may also be interested in these products
SUNDI-320/420W/430W
Cooling capacity 0.3kW~3kW Heating Power 2kW~3kW Power range 2.9kW~5kW
SUNDI -10℃~150℃
Cooling capacity 1.5kW~15kW Heating Power 2.5kW~15kW Power range 3.6kW~20kW
SUNDI -25℃~200℃
Cooling capacity 1kW~200kW Heating Power 2.5kW~200kW Power range 4kW~260kW
SUNDI -25℃~300℃
Cooling capacity 1kW~200kW Heating Power 2.5kW~200kW Power range 4kW~260kW