AET -75℃~250℃
Air Cooling Chiller For chuck/chamber/Heat plate- Temperature Control Accuracy±0.5℃
- Air treatment22m³/h~95m³/h
- Cooling Typewater cooling/air cooling
Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc.
Model | AET-4025 | AET-4050 | AET-4095W | AET-7025 | AET-7050W | AET-7095W |
AET-4025C | AET-4050C | AET-4095WC | AET-7025C | AET-7050WC | AET-7095WC | |
Temperature range | -40℃~250℃ | -75℃~250℃ | ||||
Temperature control accuracy | Gas outlet temperature control ±0.1°C, long-distance process temperature control accuracy ±0.5°C. You can choose to control the outlet gas temperature and process target temperature | |||||
Upgrade temperature rate | The temperature rise and fall rate of the gas temperature at the equipment outlet is greater than 30°C/min, and gradient temperature rise and fall can be performed | |||||
Air requirements | Air filter <5um Air oil content <0.1um Air temperature and humidity: 5°C-32℃℃ 0-50%RH Pressure 4bar~8bar | |||||
Air treatment | 22m³/h | 50m³/h | 95m³/h | 22m³/h | 50m³/h | 95m³/h |
Throttling method | The refrigeration system uses electronic expansion valve throttling to accurately control the cooling capacity | |||||
Controller | PLC programmable controller, standard support Modbus RTU protocol, RS485 interface, other communication protocols can be selected | |||||
Display record | 7-inch color touch screen, can display gas temperature, pressure, flow, refrigeration system pressure and temperature | |||||
Process temperature control | Self-created model-free self-building tree algorithm combined with general anti-lag cascade algorithm to control process temperature | |||||
Dimensions cm | 43*46*112 | 52*57*132 | 60*63*160 | 54*69*112 | 65*85*132 | 75*95*160 |
Remarks | Suffix W represents water cooling and suffix c represents gas recycling |
Descriptions
Rated test conditions: dry bulb temperature 20℃; wet bulb temperature 16℃. Inlet water temperature 20℃; outlet water temperature 25℃.
The data in this table is for reference only. Please refer to the unit nameplate parameters.
If you need special non-standard customization, please contact our company
REQUEST A QUOTE
Recommended products
FLTZ Double Frequency Conversion Series
Model FLTZ-305W FLTZ-305W/2T Double System Temp Range -30℃~40℃ -30℃~40℃ -30℃~40℃ Temp control accuracy ±0.1℃ ±0.1℃ ±0.1℃ Flow Control 15~45L/min ±0.3 15~45L/min ±0.3 15~45L/min ±0.3 Pump Pressure 6bar m…
FLTZ Multi-channel Series
Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates continuously for 24 hours Mainly used for precise temperature control in semiconductor prod…
Heat Exchange Chiller ETCU
Temp Range:+5℃~90℃ ±0.3℃ Cooling Capacity: 5kw~30kw Tank volume: 6L~15L Power: 06KW~1.6KW Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates…
loading…