ZLT HED Series 10℃~60℃
Chemical medium temperature control unit- Temperature Control Accuracy±0.1℃
- Heating capacity2KW~7.5KW
- Cooling capacity1KW~6KW
This device can directly introduce chemical media and accurately control temperature, serving as Preheating, pre cooling and temperature control of the medium before chemical reaction.
Chemical media include hydrofluoric acid, sulfuric acid, ammonia water, nitric acid, ozone water, hydrochloric acid, and hydrogen oxygen.
Sodium conversion requires confirmation of whether the concentration and temperature meet the requirements
Parameters Detailed
Model | ZLT-1HED | ZLT-3HED | ZLT-6HED | |
ZLT-1WHED | ZLT-3WHED | ZLT-6WHED | ||
Temperature range | 10 ℃~+60℃ Different media, different temperatures | |||
Temperature control accuracy | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Cooling capacity | 20℃ | 1kW | 3kW | 6kW |
Heating capacity | 2kw | 3.5kw | 7.5kw | |
Direct cooling method | Compressor | |||
Input, display | 4.3-inch/7-inch color touch screen\ PLC controller | |||
Communication | Modbus RTU protocol RS485 interface, Ethernet TCP/IP protocol | |||
Heat exchanger | Silicon carbide | |||
Interface size | G3/8 | G3/8 | G1/2 | |
Water-cooled @20℃ | 300L/H | 800L/H | 1500L/H | |
G3/8 | G3/8 | G1/2 | ||
Water-cooled condenser | The condenser of the water-cooled equipment adopts a plate heat exchanger | |||
Air-cooled condenser | Microchannel heat exchanger | Microchannel heat exchanger | Microchannel heat exchanger | |
Power supply | Single phase 220V | Three-phase 380V/220V | ||
Chemical pipe material | PFA | |||
Casing material | Cold rolled sheet spraying (REL7035) |
REQUEST A QUOTE
Recommended products
Air Cooling Chiller AET SERIES
Parameters DetailedProductDescriptionREQUEST A QUOTERecommended products Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc….
MD -75℃~225℃
Quick temperature change control chuckConfiguration DetailsProduct Description -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature un…
YQH 0℃~-75℃
Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products Suitable for the recovery of various volatile VOCs gases; Fast c…
FLT-100℃~90℃ low temperature cascade
Product data downloadConfiguration Detailschillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products Model FLTZ-803W FLTZ-805W FLTZ-806W FLT-Z808W FLTZ-810W Temp Range -80℃~+90℃ …
loading…
已经是到最后一篇内容了!