Maintenance for Lubrication System of Water Cooled Chiller Plant
Medium-sized low-temperature freezer, refrigeration temperature range from -80 ℃ ~ -30℃, safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.
When the chiller is below 80 ℃ ~ 30 ℃ below zero in the running system, people pay more attention to refrigerator, frozen water cycle system and electric control system, so the lubrication system is often overlooked. However, this system is also very important to the chiller. The maintenance of the chiller is indispensable, now we are going to tell you something about it.
1. Observe the normal oil surface, oil temperature and oil pressure in the daily inspection.
2. Regularly check the oil quality according to the oil change index stipulated in the frozen lubricating oil, and replace or supplement the filtered new oil.
3. Pay attention to check and adjust the end face clearance of the oil pump in the middle and overhaul, and replace the pump when necessary. The end face clearance of the pump varies from 0.03 to 0.08mm. Please refer to the assembly technical requirements and factory regulations of the pump for concrete value.
4. Regularly replace or clean the filter core, pipeline, and crankcase.
The maintenance of the lubrication system of the chiller requires techniques, which mainly involves the performance of the compressor’s main engine. It is recommended to be operated by professionals to avoid unnecessary losses.
Related recommendations
-
483Meet Your Dream Equipment for Distillate CBD Extraction
1798If you need equipment to distill CBD, you need to scrutinize your choices, as the equipment can vary in its features and design. When you use equipment that produces a CBD distillate, you want to seek out a system made by a manufacturer that provi...
View details -
How to Deal with Fault of Conpressor after Cold Plate Freezer for Sale?
1359In the operation of the cryogenic refrigerator refrigeration system, once the compressor fault occurs, it will affect the operation of the cryogenic refrigerator. So what are the faults that affect the compressor? How do clients settle it if the c...
View details -
Temperature control range and accuracy of high and low temperature tester
1566The temperature control accuracy of heat transfer oil medium of the high and low temperature tester used for component testing is plus or minus 0.5 ℃, which solves the problem of temperature control lag in electronic components. Main advantages of...
View details -
Low temperature cooling chiller for chemical material manufacturing process
15061. Temperature sensitive reactions control many chemical reactions that are highly sensitive to temperature, especially in the synthesis of polymer materials, pharmaceutical intermediates, and other fine chemicals. Low temp...
View details
LNEYA Industrial Chillers Manufacturer Supplier