Analysis of the reasons for non-refrigeration of cryogenic refrigeration equipment
Ultra-low temperature refrigeration equipment is mainly used in industrial cold processing. Unlike some manufacturers of ultra-low temperature refrigeration equipment, LNEYA ultra-low temperature refrigeration equipment uses environmentally friendly refrigerant, which is conducive to the operation of ultra-low temperature refrigeration equipment. If the ultra-low temperature refrigeration equipment does not cool, how to Solve it?
Generally speaking, if the ultra-low temperature freezer is not cooled, there are four main reasons. One is that the filter is clogged. When the filter is clogged, the dust on the condenser will accumulate more and more, and the refrigeration effect of the refrigeration equipment will be affected over time. . In the long run, it may even cause refrigeration equipment to fail to cool. Solution to filter blockage: Clean the filter regularly or irregularly. It is also possible that the coolant content is small, and the ultra-low temperature refrigeration coolant content is too small, which may cause the equipment to not absorb oil and reduce the cooling effect. Less coolant content Solution: Always check the coolant to see if the coolant level is maintained at high or low, and add coolant when the coolant is too low.
If the refrigeration equipment is not cooled, there may be a lack of refrigerant. In the refrigeration, after the refrigerant is used for a long time, the refrigerant will volatilize after a long use time, thereby affecting the cooling effect. Solution: Refrigerant may have certain harm to the human body, so if you encounter this situation, you should find a professional refrigeration equipment company to add. There is also the possibility that the ultra-low temperature refrigeration supply voltage is low or the power of the refrigeration equipment is insufficient, and the equipment may not be cooled.
In general, the reasons and solutions for the non-refrigeration of ultra-low temperature refrigeration equipment are as shown above. It is recommended to find that the refrigeration faults are resolved in time to avoid affecting the production of the enterprise.
Related recommendations
-
Model and size selection of cooling and heating circulator (pilot plant temperature control system)
1641The cooling and heating circulator adopts mechanical refrigeration, the low-temperature heating tube heats the high temperature, and the canned pump is used as the circulating pump. The liquid circulation of the whole system is closed and consists...
View details -
Low temperature cooling system exists in drying and freeze-drying equipment
1222In the drying and freeze-drying equipment, the low-temperature cooling system is one of the core components, which is crucial for achieving the freeze-drying process. Freeze drying (freeze-drying) is an effective method for removing moistu...
View details -
Reactor Thermal Control Unit and Solutions for Chemicals
2122Temperature control is a process in which the temperature of a substance or a change in temperature is measured or otherwise detected, and the transfer of thermal energy into or out of the space or substance is adjusted to achieve the desired temp...
View details -
New energy battery test cooling device compressor fault judgment
1696How to identify the three terminals on the fully enclosed compressor casing of the new energy battery test cooling unit? The resistance between the running end (R), the starting end (S), the common end (C), and the RS is greater than the resistanc...
View details
LNEYA Industrial Chillers Manufacturer Supplier