Routine maintenance of tcu multi-reactor temperature control equipment

TCU multi-reactor temperature control equipment is widely used in research departments such as petroleum, chemical, electronic instruments, physics, chemistry, bioengineering, physical property testing and chemical analysis, colleges and universities, enterprise quality inspection and production departments to provide users with a liquid environment with controlled cold and hot, uniform and constant temperature when working.
1. Tcu multi-reactor temperature control equipment is a heating equipment that can control the temperature of the reaction material by heating the heat transfer oil in the jacket of the reactor to transfer heat energy to the material in the reactor indirectly.
2. The whole liquid circulation is a closed system. There is no absorption of water vapor at low temperature and no oil mist at high temperature. The heat transfer oil can work at a wide temperature; The same machine and the same heat conduction medium can realize continuous temperature rise and fall control.
3. Equipped with a heating and cooling integrated container, the heat exchange area is large, the heating and cooling rate is fast, and the demand for heat transfer oil is relatively small. It can realize continuous temperature rise and fall. Refrigeration heat exchanger adopts plate heat exchanger with high heat exchange efficiency and small floor area.
4. It has self-diagnosis function, refrigerator overload protection, high-voltage pressure switch, overload relay, thermal protection device and other reliable guarantee functions, fully ensuring reliable use;
5. In case of power failure, use dry compressed air regularly to clean the inside of the machine’s electric box and heat dissipation dust to avoid electrical failure caused by metal residues falling on the electrical components;
6. During normal use, use dry compressed air regularly to clean the metal residue and dust on the fan cover of the pump inside the machine to prevent the motor from radiating poorly after the fan cover is blocked, which may cause abnormal noise or jamming of the pump motor;
7. During long-term use, regularly maintain or replace other machine parts according to other requirements in the manual. In case of shutdown, regularly clean the filter at the oil return port of the machine to avoid over-temperature alarm and other faults caused by filter blockage; Customers can formulate effective maintenance plans according to the use of the machine and the site environment.
Related recommendations
-
Test instructions for refrigeration heating temperature control system for fuel oil test
508The refrigeration heating temperature control system can be tested for different projects during operation. The detection of different projects is different. Among them, the refrigeration heating temperature control system for fuel oil testing is ...
View details -
Buying Tips of Ultra Low Temperature Freezer
430As for the industrial refrigerating treatment, the ultra low temperature freezer is indispensable. Let me tell you something about it!The ultra low temperature freezer of Wuxi Guanya Refrigeration technology co., Ltd is mainly used in industrial r...
View details -
What should I do if the 30p Refrigerated chiller compressors are overheated?
564When users purchase 30p Refrigerated chiller, they understand the internal configuration. The compressor is an important accessory in 30p Refrigerated chiller. If it overheats, 30p Refrigerated chiller will be unavailable, then 30p Refrigerated ch...
View details -
Benefits of Winterizing and Degassing Prior to Distillation
423Prior to distilling oil, you should follow a winterization and degassing procedure. The winterization will remove fats, waxes, and other inactive and unwanted compounds. Degassing will remove any solvents and other inactives with low boiling point...
View details