Precautions for customers installing Lneya’s cryogenic industrial chillers
One. When installing low-temperature industrial chillers, you need to pay attention to some installation requirements.
1. The cryogenic industrial chiller should be installed directly in a horizontal position, do not install it upside down or diagonally
2. Low-temperature industrial refrigerators generate heat during operation, and should ensure the circulation of cooling air. There should be a certain space around the installation. The generated heat is emitted upwards, so do not install it around heat-resistant equipment.
3. Freezers for low-temperature industry cannot be installed in places with various fiber paper sheets and metal fragments.
The water outlet of the cryogenic industrial chiller should be connected to the water inlet of the supporting instrument, and the water outlet of the instrument should be connected to the water inlet of the cooling circulating water machine.
Second, open the low-temperature industrial chiller, you can see the wiring terminals, do not connect the wrong wire when wiring. (Only high-power low-temperature industrial chillers have power connections)
1. The power supply must be connected to the main wire terminal. If the power supply is connected to other wire terminals by mistake, it will destroy the cryogenic industrial refrigerator. In addition, confirm whether the power supply voltage is within the allowable voltage range;
2. The ground terminal must be well grounded to prevent electric shock or fire accident;
3. Be sure to connect the terminal and the wire with a crimp terminal to ensure the reliability of the connection;
4. After completing the circuit connection, please check whether the connection is correct;
5. With or without wiring;
6. Is there a short circuit between the arrows and the connecting wire or short circuit to ground;
7. If the use temperature is below 5 degrees, please add antifreeze to the circulating fluid.
Low-temperature industrial chillers must be grounded, otherwise electric shock or fire accidents may occur. Wiring should be performed by professionals. Start the work after confirming that the power is off (OFF), otherwise an electric shock may occur.
Three. Operation of cryogenic industrial chillers
1. Check whether the check wiring is correct before starting the operation;
2. Whether the connecting water pipeline is correct and firm;
3. Confirm whether the water tank is filled with water.
Cryogenic industrial chillers are widely used and have certain applications in the pharmaceutical, chemical, petroleum and other industries. In use, you need to know their use knowledge in time to avoid problems.
Related recommendations
-
The consequences of the screw refrigerator not returning oil and the treatment method
507In the cooling operation of the screw refrigerator, if the refrigerant is in contact with the lubricating oil, the lubricating oil in the compressor will enter the condenser with the operation of the refrigeration system and the gaseous or misty r...
View details -
Current status of hot and cold rapid temperature change test chamber
376At present, manufacturers of hot and cold rapid temperature change test chambers are sprouting like spring bamboo shoots, but there are several manufacturers that really grasp the quality. When purchasing a test box, the buyer must first look at t...
View details -
Treatment of organic waste gas by condensation method
486Condensation treatment of organic waste gas equipment should pay attention to its performance when selecting. It is very necessary to choose high-performance condensation method to treat organic waste gas. So what is the use of organic waste gas f...
View details -
Laboratory chiller refrigeration temperature control system equipment
519Lab water chillers, as the name implies, are mainly used in colleges and universities, scientific research and laboratories. Specially for the cooling of small laboratory equipment such as spectrometer, mass spectrometer, viscometer, rotation, fer...
View details