Description of the action of the filter in the ultra-low temperature compressor unit
In order to stabilize the operation of the ultra-low temperature compressor unit, the performance of the compressor is very important, and in addition to the compressor, the filter is also important.
In order to maintain normal operation, it is necessary to ensure the normal use of the refrigerant. In the entire ultra-low temperature compressor cycle system, the refrigerant cannot be completely unaffected. During the normal cycle operation, the refrigerant will contain more and more. Metal scraps, as well as other magazines, are inevitable in normal operation.
However, if the refrigerant contains these impurities, it will definitely affect its normal operation, which will seriously affect the overall refrigeration quality of the ultra-low temperature compressor unit. At the same time, it will cause damage to the compressor and other components. Therefore, the refrigerant needs to be filtered. This is the filter. Play a role.
Ultra-low temperature compressor set filter refers to the device that provides filtration service for the refrigerant. Usually it is put together with the dryer. It is two-in-one, but the filter itself can be cleaned, cleaned and replaced separately. In general, in industrial ultra-low temperature compressor units, there must be a filter device. The filter does not have any deep design, that is, through the extremely dense mesh device, the metal debris and other materials in the refrigerant. Impurities are filtered.
The function of the filter is simply to clean the refrigerant and allow the refrigerant to be recycled many times. If there is no filter, the refrigerant can not be recycled normally. It may be a few days later. The maintenance of the filter also requires a snack. The frequency and various aspects of the filter in the ultra-low temperature compressor group under different environments and different operating intensities are also different. Secondly, if conditions permit, it is recommended to replace the filter once a month, or three months later, otherwise it will affect the use of the filter.
Of course, the different types of filter models of the ultra-low temperature compressor group are also different, and the user can select the corresponding condenser according to the specific working conditions.
Related recommendations
-
Meet in Shanghai World Expo Pavilion 【Pesticide Exhibition】Booth 1G10 10.12-10.14
1932Exhibition name: The 20th National Pesticide Exchange Conference and Agrochemical Products Exhibition HallExhibition time: October 12-14, 2020Booth number: 1G10Exhibition address: Shanghai World Expo Exhibition Hall ,
View details -
Introduction Of Low Temperature Refrigeration Equipment Series-low Temp Process Chillers
1490Thermoacoustic refrigeration technology is a new refrigeration method with wide application prospects. It is one of the major advances in refrigeration and cryogenic technology in the past 30 years. Thermoacoustic engine uses thermoacoustic effect...
View details -
What Are the Differences Between Low Temperature Test Chamber and Refrigeration?
1916The low temperature test chamber, you can see by its name, probably means to do cryogenic test. It is more important in our refrigeration equipment. The small series of low temperature test chamber tells you that the refrigeration of low temperatu...
View details -
High-low temperature control system with different configurations of high-pressure reactors
1314Different configurations of high pressure reactors, the quality of products brought by different manufacturers is not the same, but the points of attention are the same, you need to pay attention to it. 1. To be used at the designated location and...
View details