SEARCH
Search the allChillersWater ChillerSUNDI series
Search
Hot Products
Thermoatats SUNDI Series/ TCU/KRY series/WTD seriesChillers LT series/ FL series/CDYL seriesAir Cooling Chiller Water Cooling Chiller
SEARCH
Model | UC-3530 | UC-5530 | UC-7530 | UC-A1030 | UC-A1530 | UC-A2530 | UC-A3830 | UC-A6030 | UC-A9530 | UC-A13030 | |
Temperature range | 50℃~300℃ | ||||||||||
Controller | PID adaptive controller | ||||||||||
Temp. control optional | Heat-conducting medium outlet temp. control | ||||||||||
Communication protocol | MODBUS RTU protocol RS 485 interface | ||||||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | ||||||||||
Temp. accuracy | ±0.5℃ | ||||||||||
Heating power | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | |
Cooling capacity | 300℃ | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW |
200℃ | 3.5kW | 5..5kW | 7.5kW | 10kW | 13kW | 25kW | 38kW | 60kW | 95kW | 130kW | |
100℃ | 2.8kW | 4kW | 5kW | 7kW | 12kW | 20kW | 30kW | 48kW | 76kW | 100kW | |
65℃ | 1kW | 1.8kW | 2.2kW | 3kW | 5kW | 8.5kW | 12kW | 19kW | 30kW | 40kW | |
Circulation pump | Max35L/min 1.2BAR | Max35L/min 1.2BAR | Max50L/min 1.2BAR | Max50L/min 1.2BAR | Max110L/min 1.5BAR | Max150L/min 1.5BAR | Max200L/min 1.5BAR | Max250L/min 2.5BAR | Max400L/min 2.5BAR | Max400L/min 2.5BAR | |
Heater | Flanged pipe electric heater | ||||||||||
Independent temperature limiter | Lneya | ||||||||||
Cooler | Plate heat exchanger/Tube heat exchanger | ||||||||||
Operation panel | Display set temperature and measured temperature,key operation input temperature | ||||||||||
Sefety protection | Self-diagnostics;High pressure switch,overload relay、variety of security features such as thermal protection devices. | ||||||||||
Closed circulation system | The entire system is a fully enclosed system,no oil mist at high temperatures、low temperature does not absorb moisture in the air | ||||||||||
System | The system does not increase the pressure due to high temperature during operation,low temperature automatically replenishes the heat transfer medium. | ||||||||||
Connection size | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | DN50 PN10 | |
Dimensions cm | 40*70*130 | 40*70*130 | 45*70*160 | 45*70*160 | 70*100*175 | 70*100*175 | 80*100*185 | 150*100*185 | 200*145*205 | 200*145*205 | |
Weight kg | 95 | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 1220 | 1400 | |
Power | 5KW | 7KW | 9KW | 12kw | 17kw | 28kw | 41kw | 65kw | 101kw | 136kw | |
Case material | Cold rolled sheet spray | ||||||||||
Optional | Optional 7-inch color touch screen,recording temperature curve,data export using excel format | ||||||||||
Optional | SUS304 shell | ||||||||||
Optional | Optional external touch screen controller,communication line distance 10m | ||||||||||
Optional | Optional explosion-proof touch screen control system(ExdeIIBT4),communication line distance 10m | ||||||||||
Optional power | 220V 60HZ three phase,440V~480V 60HZ three phase |
UC series matching and application:
Reactors, reactors, analytical instruments, distillation systems, microchannels, etc. for high temperature and cooling reactions.
Thermal chuck or Thermal plate/Thermal control unit for ic test cooling
Cooling Power 0.6~3kW Heating Power 2~3.5kW Flow Control 12~45L/min Heat Transfer Oil Fluorinated fluid
Temperture accuracy ±0.1℃ Cooling Power 5~11kW Heating Power 2.5kW
Temperture accuracy ±0.1℃ Cooling Power 6~40kW Refrigent R410A
loading…