Model | UC-3530 | UC-5530 | UC-7530 | UC-A1030 | UC-A1530 | UC-A2530 | UC-A3830 | UC-A6030 | UC-A9530 | UC-A13030 | UC-A20030 | |
Temp. range | 50℃~300℃ | |||||||||||
Controller | PID adaptive controller | |||||||||||
Temp. control optional |
Heat-conducting medium outlet temp. control | |||||||||||
Communication protocol |
MODBUS RTU protocol RS 485 interface | |||||||||||
Temperature feedback |
Heat-conducting medium temperature feedback PT100 | |||||||||||
Temp. accuracy | ±0.5℃ | |||||||||||
Heating power | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | 200kW | |
Cooling capacity |
300℃ | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | 200kW |
200℃ | 3.5kW | 5..5kW | 7.5kW | 10kW | 13kW | 25kW | 38kW | 60kW | 95kW | 130kW | 200kW | |
100℃ | 2.8kW | 4kW | 5kW | 7kW | 12kW | 20kW | 30kW | 48kW | 76kW | 100kW | 160kW | |
65℃ | 1kW | 1.8kW | 2.2kW | 3kW | 5kW | 8.5kW | 12kW | 19kW | 30kW | 40kW | 64kW | |
There are heat exchangers in the system,need to pass water to cool,automatically open the inlet valve as needed | ||||||||||||
Circulation pump |
Max35 L/min 2BAR |
Max50 L/min 2BAR |
Max75 L/min 2BAR |
Max110 L/min 2.5BAR |
Max110 L/min 2.5BAR |
Max150 L/min 2.5BAR |
Max200 L/min 2.5BAR |
Max250 L/min 2.5BAR |
Max400 L/min 2.5BAR |
Max400 L/min 2.5BAR |
Max600 L/min 3BAR |
|
Heater | Flanged pipe electric heater | |||||||||||
Independent tempe. limiter |
Lneya | |||||||||||
Cooler | Plate heat exchanger/Tube heat exchanger | |||||||||||
Operation panel | Display set temperature and measured temperature,key operation input temperature | |||||||||||
Sefety protection | Self-diagnostics;High pressure switch,overload relay、variety of security features such as thermal protection devices. | |||||||||||
Closed circulation system | The entire system is a fully enclosed system,no oil mist at high temperatures、low temperature does not absorb moisture in the air | |||||||||||
System | The system does not increase the pressure due to high temperature during operation,low temperature automatically replenishes the heat transfer medium. | |||||||||||
Connection size | G3/4 | G3/4 | G1 | G1 | G1 | DN32 | DN40 | DN40 | DN50 | DN50 | DN65 | |
Dimensions cm |
45*85 *130 |
45*85 *130 |
45*85 *130 |
55*95 *170 |
55*95 *170 |
70*100 *175 |
80*120 *185 |
100*150 *185 |
205*145 *205 |
205*145 *205 |
275*160 *225 |
|
Weight kg | 95 | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 1220 | 1400 | 2150 | |
Power | 5KW | 7KW | 9KW | 12kw | 17kw | 28kw | 41kw | 65kw | 101kw | 136kw | 212kw | |
Case material | Cold rolled sheet spray | |||||||||||
Optional | Optional 7-inch color touch screen,recording temperature curve,data export using excel format | |||||||||||
Optional | SUS304 shell | |||||||||||
Optional | Optional external touch screen controller,communication line distance 10m | |||||||||||
Optional | Optional explosion-proof touch screen control system(ExdeIIBT4),communication line distance 15m | |||||||||||
Optional power | 220V 60HZ three phase,440V~480V 60HZ three phase |