AES -115℃~225℃
Temperature Forcing System/ “Thermal Stream”- Time switching10s~20s
- RefrigerantR404A/R23/R14/R508B
- Cooling water0.6m³/h~3m³/h
- Power range3.7kW~7.5kW
Product data download
TEMP SHOCK TEST AIRFLOW HOOD
1/CHARACTERISTIC ANALYSIS
2/LOOP TEST
3/IMPACT TEST
4/FAILURE ANALYSIS
Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc.
Parameters Detailed
Model | AES-4535 | AES-6035 | AES-8035 | AES-A1035W | AES-A1235W | |
AES-4535W | AES-6035W | AES-8035W | ||||
Temp. Range | -45℃~225℃ | -60℃~225℃ | -80℃~225℃ | -100℃~225℃ | -120℃~225℃ | |
Heating Power | 3.5kW | 3.5kW | 3.5kW | 4.5kW | 4.5kW | |
Temp. Control Accuracy | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. Conversion Time | -25℃ to 150℃ Approximately 10S 150℃ to -25℃ Approximately 20s |
-45℃ to 150℃ Approximately 10S 150℃to -45℃ Approximately 20s |
-55℃ to 150℃ Approximately 10S 150℃to -55℃ Approximately 15s |
-70℃ to 150℃ Approximately 10S 150 ℃to -70℃ Approximately 20s |
-80℃ to 150℃ Approximately 11S 150℃to -80℃ Approximately 20s |
|
Air Requirement | Air Cleaner<5um | |||||
Air Oil Content:<0.1ppm | ||||||
Air Temp&Humidity:5℃~32℃ 0~50%RH | ||||||
Air Handing Capacity | 7m3/h ~ 25m3/h Pressure 5bar~7.6bar | |||||
System Pressure Dispiay | Pressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure); | |||||
Pressure of circulatory system is detected by pressure sensor and displayed on touch screen. | ||||||
Controller | Siemens PLC, Fuzzy PID Control algorithm. | |||||
Temp. Control | Control of outlet temperature | |||||
Programmable | 10 procedures can be developed, and each program can be composed of 45 steps | |||||
Communicating Protocol | Ethernet Interface TCP/IP Protocol. | |||||
Internal Temp. Feedback | Equipment outlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured) . | |||||
Temp. Feedback | T Temperature Sensor | |||||
Compression Engine | Taikang,France | Taikang,France | Taikang,France | Italy Duling | Italy Duling | |
Evaporimeter | Double-pipe (heat) Exchanger | |||||
Calorifier | Flanged Barrel Heater | |||||
Refrigeration Accessory | Danfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves, solenoid valves). | |||||
Operation Panel | LNEYA custom 7-inch color touch screen, temperature curve display\ EXCEL data export. | |||||
Safe Guarding | With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. | |||||
Cryogen | Topsubmixed Refrigerant | |||||
External Insulation Hose | 8m DN32 fast coupling clamp for easy outgoing insulation hose | |||||
Refrigerant | R404A | R404A/R23 | R404A/R508B | R404A/R23/R14 | R404A/R23/R14 | |
Shape Dimension (Wind)cm | 54*69*132 | 54*69*132 | 75*73*133 | 80*120*185 | 100*150*185 | |
Shape Size (Water)cm | 54*69*132 | 54*69*132 | 75*73*133 | 70*100*175 | 80*120*185 | |
Air-Cooled Type | Copper tube aluminum fin condensation mode, upper and out type, condensing fan using Germany EBM axial flow fan. | |||||
Water-Cooled Type W | Type W is water cooled | |||||
Water-Cooled Condenser | Sleeve type heat exchanger (Paris/ Shen’s) | |||||
Cooling Water Quantity At 25℃ | 0.6m3/h | 1.2m3/h | 1.6m3/h | 2.6m3/h | 3m3/h | |
Source 380V 50HZ | 3.7kW max | 5kW max | 5kW max | 6.8kW max | 7.5kW max | |
Source | Customizable 460V 60HZN 220V 60HZ three-phase | |||||
Shell Material | Cold rolled sheet spray (Standard Colour 7035). | |||||
Temp. Spread | High Temperature To +300℃ |
Product Description
The output airflow cover of the testing machine will be covered bythe test product to form a test chamber with a relatively closedspace. The high or low temp airflow output by the testing machinewill cause the surface temp of the test product to change drastically,thus completing the corresponding high and low temp impact test.
It can isolate one lC or original component among many componentsand separately perform high and low tempimpact withoutaffecting other surrounding devices. Compared with the traditionalthermal shock test box, the temp impact rate is faster.
Provides accurate and fast ambient temperature (-120 °C ~ +300 °C) for chips, modules, integrated circuit boards, and electronic components. It is an indispensable instrument for product electrical performance testing, failure analysis, and reliability assessment.
Widely used in semiconductor companies, aerospace, optical communications, universities, research institutes and other fields.
Compared to the traditional thermostat, there are several features:
Temperature range: -120 °C ~ +300 °C;
The temperature rise and fall is very fast, -55 °C ~ 150 °C < 10 seconds;
Temperature control accuracy: ±1 °C;
Temperature setting capability: ±0.1 °C;
Temperature display capability: ±0.1 °C;
Maximum air flow: 25m3/h;
Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time;
The temperature rise and fall time is controllable, programmable operation, manual operation and remote control.
PRODUCT ADVANTAGES
1/LCD 2/insulation hose 3/Mechanical arm 4/Heating head 5/Heat hood
1/Oil mist separator 2/Micro mist separator 3/Air dryer 4/Pressure reducing valve
You may also be interested in these products
MD -75℃~225℃
INQUIRY Configuration Details Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature uniformity ±1℃ ±1℃ ±1℃ …
YQH 0℃~-75℃
Temperture accuracy ±0.1℃ Flow control 12~45/min
FLT-100℃~80℃ low temperature cascade
Temperture accuracy ±0.1℃ Flow control 12~45/min
FLTZ -30℃~40℃ Double frequency conversion series
Temperture accuracy ±0.1℃ Flow control 15~45/min 6bar max Power range 380V 3.5kW
loading…
已经是到最后一篇内容了!