KRYCH Series Battery Pack Test Chamber
APPLICATIONS
The power battery temperature cycle chamber is a high and low temperature test device for power battery samples. It is currently mainly used in the new energy battery industry. It can directly complete high and low temperature charging and discharging, or high and low temperature storage, for battery cells, modules, and PACKs in the test box. In the event of battery failure, explosion-proof pressure relief and fire protection devices are added.
Product Features
Product Parameters
GD series & KRYCH series -40℃~100℃
Model | GD-9000-2-B1-KRYCH-4A15W | GD-9000-2-B1-KRYCH-475W | GD-9000-2-B1-KRYCH-4A10W | GD-1000-B1-KRYCH-475 | |||||
Temperature range | -40℃~100℃ Antifreeze |
-40℃~100℃ Test Chamber |
-40℃~100℃ Antifreeze |
-40℃~100℃ Test Chamber |
-40℃~100℃ Antifreeze |
-40℃~100℃ Test Chamber |
-40℃~100℃ Antifreeze |
-40℃~100℃ Test Chamber |
|
Antifreeze flow control | 1L/min~40L/min | 1L/min~25L/min | 1L/min~25L/min | 1L/min~10L/min | |||||
±0.2L/min | ±0.2L/min | ±0.2L/min | ±0.2L/min | ||||||
Antifreeze pressure | Measure and display the inlet and outlet pressure, as well as the pressure displayed on the touch screen | ||||||||
Chamber(W*H*D) | Upper cavity cm | 220*322*120 | 220*322*120 | 220*322*120 | Single cavity:100*100*100 | ||||
Lower cavitycm | 220*322*110 | 220*322*110 | 220*322*110 | ||||||
Heating power | 15kW | 14kW | 7.5kW | 14kW | 10kW | 14kW | 7.5kW | 6kW | |
Cooling capacity Antifreeze |
135℃ | 15kW | 7.5kW | 10KW | 7.5kW | ||||
20°℃ | 15kW | 7.5kW | 10KW | 7.5kW | |||||
0℃ | 15kW | 7.5kW | 10KW | 7.5kW | |||||
-20℃ | 10kW | 4.5kW | 6KW | 4.5kW | |||||
-35℃ | 4kW | 1.8kW | 2.5KW | 1.8kW | |||||
Chamber | Heating rate | 25~+100℃≥±2℃/Min (No load, average throughout the entire process) (Customizable at 5~25℃) | |||||||
Cooling rate | 25~-40℃≥1℃/Min(No load, average throughout the entire process) (Customizable at 5~25℃) | ||||||||
Antifreeze temp control accuracy | ±0.1℃ | ||||||||
Temperature uniformity | ≤±1℃(unloaded) | ||||||||
Circulating air volume | 5000m³/h | 2500m³/h | |||||||
Control mode | Segmented Fuzzy PID Algorithm Control | ||||||||
Communication protocol | CAN/TCP/RS485 | ||||||||
Temperature feedback | Internal temperature of equipment enclosure, condensation temperature of refrigeration system, suction temperature of compressor, cooling water temperature (for water-cooled equipment) |
||||||||
High temp cooling module | Can cool down from a high temperature of 100 ℃ | ||||||||
Circulating pump | Magnetic drive pump | ||||||||
Compressor | Brand variable frequency compressor | ||||||||
Evaporator | Plate/fin heat exchanger | ||||||||
Refrigeration accessories | Emerson/Danfoss brand dry filters, oil separators, etc | ||||||||
Throttle method | Electronic expansion valve | ||||||||
Refrigerant | R125/R404A | ||||||||
Safety protection | Phase sequence failure protector, freezer overload protection; High pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||||||
water-cooled condenser | Shell and tube heat exchanger | ||||||||
Operation panel | 10 inch color touch screen | 7 inch color touch screen | |||||||
Antifreeze interface | ZG3/4 | ZG3/8 | |||||||
Cooling water 20 ℃ | 25m³/H | 20m³/H | 20m³/H | 7m³/H | |||||
Dimension cm | 240*560*285 | 240*560*285 | 240*560*285 | 120*205*205 | |||||
Bearing | 1500kg | 1500kg | 1500kg | 120kg | |||||
Weight | 4600kg | 4200kg | 4200kg | 600kg | |||||
Power supply | 380V 50HZ | ||||||||
Insulation material | Glass fiber cotton&polyurethane | ||||||||
Inner box material | SUS304 stainless steel brushed plate | ||||||||
External materia | Cold rolled steel plate+spray coating | ||||||||
Execution standards | GB/T 2423.1;GB/T 2423.2;GB/T 2423.3;GB/T 2423.4;GB/T 5170.2;GB/T 5170.5;GB/T 11158;GB/T 10589;GB/T 10592; GB/T 10586;IEC 60068 |
contact us
Submit your request to us and we will contact you within 24 hours