Wuxi Guanya Refrigeration Technology co., ltd

Motor test bench environmental cabin option for new energy vehicles

Passenger car motor and commercial vehicle motor test bench can complete the stall torque and locked rotor current test, temperature rise test, continuous electric working characteristic test, motor maximum speed test, motor over speed test and feed operation characteristic test. At the same time, the test bench can feed the electricity generated during the test to the company's power grid through the frequency conversion system.

Motor labs and performance dynamometers must contain functions that control the stimulating elements of the application, the most difficult of which is usually temperature cycling. Many systems are designed to be propelled into the environmental chamber and, if necessary, shield any sensitive power tool test components from extreme temperatures or humidity.

The measurement and control system consists of a host computer monitoring system, a data acquisition system, a sensor measurement system, a frequency converter control system, a test bench auxiliary equipment control system, a safety monitoring system, and an early failure warning system. The measurement and control system uses a real-time bus as the main communication network and a CAN bus that communicates with the device under test. The upper computer monitoring system communicates with the data acquisition system and the inverter control system through real-time bus, dynamically controls the motor in real time, collects the data of each sensor at high speed, and analyzes and processes the data. The lower computer controller communicates with each auxiliary test system, and controls the auxiliary test system, and simultaneously collects the sensor data of each safety monitoring, such as: motor temperature, bearing temperature, coolant temperature, cooling pressure, etc.; The DI/DO interface controls, for example, the system issues an emergency stop command, and the lower controller immediately outputs the corresponding DO signal to cut off the power of the corresponding system to ensure system safety.

LNEYA new energy battery motor test temperature control system KRY equipment is widely used in the industry, one can connect multiple test equipment at the same time, achieve precise temperature control, and do not interfere with the temperature control process.

(Some of the content comes from the Internet. If there is any infringement, you can contact and modify it, thank you!)
Related News
  • LNEYA Is Exhibiting At Achema 2018

    LNEYA Is Exhibiting At Achema 2018

    January 11, 2018​The LNEYA Group will participate in the ACHEMA -World Forum and Leading Show for the Process Industries,Frankfurt am Main, Germany.view
  • Approaching LNEYA 5 Main Products

    Approaching LNEYA 5 Main Products

    January 11, 2018Industrial Chiller:Industrial Chiller varies from dynamic temp. Special Chiller:Special Chiller consist of Multi-reactor chiller (TCU).Environmental Chamber:The test object is connected to a testing adapter. Industrial Freezer:Industrial freezer consist oview
  • The Analysis Of Ultra Low Freezer'S Price

    The Analysis Of Ultra Low Freezer'S Price

    July 4, 2018What are the characteristics and functions of ultra low freezer: 1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the proce...view
  • The Application of Cold Plate Freezer

    The Application of Cold Plate Freezer

    July 4, 2018The refrigeration system of cold plate freezer adopts secondary super-cooler technology with the rapid refrigeration and low limiting temperature. It uses imported brand name semi-hermetic piston comp...view
  • 2018 Automotive Testing Expo

    2018 Automotive Testing Expo

    September 11, 2018Automotive Testing Expo 9.25-9.27view
  • The Analysis Of How To Maintain The Low Temperature Circulator In Daily Life

    The Analysis Of How To Maintain The Low Temperature Circulator In Daily Life

    July 4, 2018Guanya is a leading role in heating cooling circulator. It provides the customers with proposal and technology of controlling the cold and heat, temperature control system with stable property, extend...view
Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • LT -45℃~30℃

    LT -45℃~30℃

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
  • TES -45℃~250℃

    TES -45℃~250℃

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • TES -85℃~200℃

    TES -85℃~200℃

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view
products
Contact
Tel: + 86 18751545184
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat