Introduction to cold plate liquid cooling system products and equipment
With the stringent PUE requirements in different regions and the widespread application of high-density servers, data center cooling methods are increasingly developed and used. Below, the cold plate liquid cooling system manufacturer Crown Asia Refrigeration introduces several traditional and new cooling methods in data centers.
- Composition of cold plate liquid cooling system
The cold plate liquid cooling system has a simple structure. The unit mainly consists of a frame, chilled water coil, fan, electromagnetic two-way regulating valve, control system, inlet and outlet air temperature and humidity sensors, chilled water pipelines, etc.
- Product introduction of cold plate liquid cooling system
The cold plate liquid cooling system is suitable for semiconductor testing, constant temperature testing of electronic equipment, cooling server supporting infrastructure, and other fluid temperature control places. The cold plate liquid cooling system is a modular intelligent device with independent heat exchange system, power supply system and monitoring system.
- Application of cold plate liquid cooling system
Currently, traditional air-cooling technology can no longer meet the pursuit of higher performance and lower energy consumption in modern data centers. In order to improve the efficiency of data center use and better meet the cooling needs of high-power density cabinets, Crown Asia Refrigeration has launched a cold plate liquid cooling system with independent heat exchange system, power supply system and monitoring system, modular intelligent CDU heat dissipation It can reach 300kw, helping the data center reduce the annual PUE to less than 1.2.

Provide 7 * 24 free consultation and comprehensive solutions


Email: sales@cnzlj.com
WhatsApp: 086 13912479193
Related recommendations
-
LNEYA data center liquid cooling solution Liquid Cooled CDU Distribution Unit
1022LNEYA data center liquid cooling chiller CDU
View details -
Immersion phase change liquid cooling system
901What is immersion phase change liquid cooling system?
View details -
Discussion on maintenance of high and low temperature integrated cycle machine
937LNEYA high and low temperature integrated cycle machine is a refrigeration heating equipment produced by the use of refrigeration heating dynamic temperature control technology. The temperature range is from -120 °C to 350 °C. It has superior perf...
View details -
Aspects to be aware of when using an air-cooled all-in-one
758The air-cooled all-in-one is in operation, unless it is necessary, please do not open the chassis door, otherwise the following adverse consequences may result. When the equipment is subjected to a high temperature test, it is very dangerous to bl...
View details -
How to deal with chip failure in integrated circuit chip test?
987The integrated circuit chip test is used in various chips, semiconductors, and component tests. Once the chip fails, the test work will stop. Therefore, the ineffective user of the integrated circuit chip test needs to know clearly. The purpose of...
View details -
Low temperature industrial freezer fan coil wiring instructions
934The electric two-way valve red line of the low-temperature industrial freezer is 220V hot wire (L) directly connected to the thermostat fire line interface, the blue line is zero line (N), the coil, the two-way valve, the thermostat is connected i...
View details
Submit for consultation
We will reply to you within 24 hours