The coolant distribution unit of our LNEYA can be said to be a liquid-to-liquid type, which greatly reduces the ratio of high loss of coolant in the past, and has high safety and reliability.

ZLFQ series Temperature accuracy ±0.2℃

Model
ZLFQ-15
ZLFQ-25
ZLFQ-50
ZLFQ-75
ZLFQ-100
ZLFQ-150
Temp Range
Cooling Water Temperature+5℃~35℃ 
Cooling Water 
5℃~30℃ Adopt Siemens/Honeywell regulating valve to control cooling water flow
Temp Control Accuracy
±0.2℃
±0.5℃
Flow Control
10~25L/min
25~50L/min
40~110L/min
70~150L/min
150~250L/min
200~400L/min
 
The flow control is adjusted by frequency converter, the precision ±0.3L/min
Cooling Capacity(MAX)
15kW
25kW
50kW
75kW
100kW
150kW
Storage Volume
15L
30L
60L
100L
150L
200L
Brine
Water, silicone oil, fluorinated liquid, ethylene glycol aqueous solution, etc.
Controller
PLC, fuzzy PID control algorithm, with cascade control algorithm
Temp Control
Heat transfer medium outlet temperature control mode, with cascade control algorithm
Letter of agreement
Ethernet interface TCP/IP protocol  
RS485 interface modbus RTU protocol
Device Internal Temperature Feedback
Equipment heat transfer medium outlet temperature, medium inlet temperature, cooling water temperature
Tank Level
Import and export pressure sensor detection, cooling water pressure detection
Medium Pipeline
SUS304
Heat Exchanger
Plate heat exchanger, special attention: need to use clean factory water
Operation Panel
LNEYA customized 7-inch color touch screen, temperature curve display\EXCEL data export
Security
With self-diagnosis function; phase sequence and phase failure protector; pressure protection, overload relay, thermal protection device and other safety protection functions.
In and out interface size
ZG3/4
ZG1
ZG1
DN32
DN40
DN50
Cooling water interface
ZG3/4
ZG1
DN40
DN50
DN50
DN65
Cooling Method
Water-cooled, the factory water temperature is lower than the minimum temperature provided by the equipment by more than 3°C, and the water temperature fluctuation is ≤3°C
Cooling Water Flow   7~20℃
2.5m³/h
4m³/h
8m³/h
13m³/h
17m³/h
25m³/h
Power 380V 50HZ
 1kW
1.5kW
3kW
4kW
5kW
6kW
Shell Material
Cold-rolled

ZLFQ series Temperature accuracy ±0.5℃

Cabinet-type liquid cooling CDU-300kW

Model
ZLFQ-200
ZLFQ-250
ZLFQ-300
ZLFQ-400
ZLFQ-500
Temp Range
Cooling Water Temperature+5℃~35℃ 
Temp Control Accuracy
±0.5℃
Flow Control  
15~30m³/h
20~35m³/h
25~40m³/h
30~60m³/h
40~70m³/h
 
Flow control is adjusted by frequency converter
Cooling Capacity(MAX)
 200kW
250kW
300kW
400kW
500kW
Storage Volume
250L
300L
600L
1000L
1200L
Cooling Method
Heat exchange between factory service water and brine, and brine provides cooling capacity for heating equipment
Brine
Water, silicone oil, fluorinated liquid, ethylene glycol aqueous solution, etc.
Controller
PLC, fuzzy PID control algorithm, with cascade control algorithm
Temp Control
Heat transfer medium outlet temperature control mode
Letter of agreement
Ethernet interface TCP/IP protocol  
RS485 interface modbus RTU protocol
Device Internal Temperature Feedback
Equipment heat transfer medium outlet temperature, medium inlet temperature, cooling water temperature
Tank Level
Pressure sensor real-time monitoring
Medium Pipeline
SUS304
System Pressure
Using the pressure sensor to detect and display on the touch screen
Heat Exchanger
Plate heat exchanger, special attention: need to use clean factory water
Operation Panel
LNEYA customized 7-inch color touch screen, temperature curve display\EXCEL data export
Security
With self-diagnosis function; phase sequence and phase failure protector; pressure protection, overload relay, thermal protection device and other safety protection functions.
In and out interface size
DN65
DN65
DN65
DN80
DN80
Cooling water interface
DN80
DN80
DN100
DN100
DN125
Cooling Method
Water-cooled, the factory water temperature is lower than the minimum temperature provided by the equipment by more than 3°C, and the water temperature fluctuation is ≤3°C

*
*
Submitting~
Submitted successfully!
Submission failed!
error~
error~

Indirect contact liquid cooling system: heat is exchanged with the coolant inside the server in the heat exchanger outside the server through an intermediary fluid (such as fluorinated liquid), and then the intermediary fluid is transferred to the external cooling system.

  • Fengliu structure
  • Heat dissipation up to 12kW
  • PUE≤1.2
  • Plug-in frame design
  • Hot and cold aisle isolation
  • The heat dissipation is as high as 15kW, which can quickly complete the construction of edge computer rooms and the transformation of old computer rooms. Annual OUE≤1.2, heat exchange increased by 10%.

Mainly Used For:

5G Base Station

Internet Data Center

Power Industry

Supercomputing Center

Financial Data Center

Game Rendering Industrial

Research Institutions

Medical Industry

WeChat ID 086 15152266993

WhatsApp: 086 13912479193

Recommend Products

The prev: The next:

Related recommendations

  • ST series

    1748

    ST-25W ST-38W ST-60W ST-100W ST-200W ST-300W Steam pressure 4~6bar Hot water temperature range RT+10℃~135℃ Temperature control accuracy ±1℃ ±1℃ ±1℃ ±1℃ ±1℃ ±1℃ Heat transfer capacity max 25kW 38kW 60kW 100kW 200kW 300kW Steam...

    View details
  • Rotary Evaporator 1-50L

    1559

    Small desktop rotary Evaporator 1L~5L Pilot and ground mounted rotary evaporators 10L~50L Rotary evaporator, also known as rotary evaporator. It consists of motor, distillation flask, heating pot, condenser and other parts. It is...

    View details
  • AET Series

    3427

    Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc. Rated test conditions: dry bulb temperature 20℃; wet...

    View details
  • Molecular distillation (Short range distillation)

    1740

    Short range distillation (molecular distillation) is a new separation technology that can solve problems that conventional distillation techniques cannot solve. It can achieve liquid-liquid separation at temperatures far below the boilin...

    View details