
Global service
30,000 +customers.
20+ countries.

Certification patents
CE ,SGS, ISO certification.

After-sales service
24/7 solutions.

Professional team
15+ years experience.

Quality control
Quality test.
Search the whole station
The WTD vacuum chiller has a temperature control accuracy of up to ±0.3℃ and a temperature range of -70℃ to 300℃, giving you a more accurate, stable and efficient temperature control experience.
lowest
Highest
Temperature control accuracy
Medium & Material
Contact LNEYA sales engineer
for catalog or price.
Model | WTD-120M | WTD-255 | WTD-455 | WTD-755 | WTD-275V | |
Temp Range | -5°C~120°C | -25°C~200°C | -45°C~250°C | -70°C~200°C | -20°C~300°C | |
Temp resolution | 0.1K | |||||
Control model | PID Adaptive controller | |||||
Heating capacity | 2kW | 5.5kW | 5.5kW | 5.5kW | 7.5kW | |
Cooling capacity kW | 300°C | 7.5kW | ||||
200°C | 5.5kW | 5.5kW | 5.5kW | 7.5kW | ||
100°C | 1.5kW | 5.5kW | 5 kW | 5 kW | 7.5kW | |
20°C | 1 kW | 5.5kW | 5 kW | 5 kW | 5.5kW | |
-15°C | 2.5kW | 4 kW | 4 kW | 2.5kW | ||
-35°C | 1.5kW | 3 kW | ||||
-60°C | 1.1kW | |||||
Circulation pump max | 7L/min 2.5bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | |
Temp sensor | PT100 | PT100 | PT100 | PT100 | PT100 | |
Cooling way | Air-cooled | Air cooled+water cooled | ||||
Heating-conduction medium | Synthetic heat conducting oil | |||||
Power 380V 50HZ | 220V 3.1kW | 9.5kW MAX | 10kW MAX | 12kW MAX | 15kW MAX |
Floor space
The WTD recirculating chiller heater uses a plate heat exchanger with a compact structure and a small footprint, which is suitable for use in places with limited space. The bottom is equipped with 4 casters, which is convenient for you to move the position at any time according to your needs.
Core accessories
The accessories of the WTD industrial chiller heater are basically internationally renowned brands. For example, the compressor uses Secop, Emerson Copeland and French Tecumseh, etc.; the dry filter uses Danfoss; the contactor/circuit breaker uses Schneider.
Cannabis extraction
Cannabinoids and other active ingredients contained in cannabis are important for medical treatment, but a key factor in cannabis extraction is temperature control in processes such as extraction, distillation, crystallization, and solvent recovery. Only by accurately and stably controlling the temperature environment with the help of chiller heater units can we help improve the efficiency of extraction and the quality of products.
Pharmaceuticals
In the pharmaceutical process, researchers need to use laboratory thermostats to change the temperature environment, understand the stability of drugs at different temperatures, and observe the changes in their efficacy and activity.
30,000 +customers.
20+ countries.
CE ,SGS, ISO certification.
24/7 solutions.
15+ years experience.
Quality test.
Can’t find a suitable chiller? Or don’t know how to choose a chiller? Contact us now to get chiller details and prices
Contact LNEYA
Submit your request to us and we will contact you within 24 hours