SUNDI-10℃~150℃ chiller heater unit has both cooling and heating capabilities, temperature range -10℃~150℃, heat transfer medium temperature control accuracy ±0.5℃.
Source chiller manufacturer, full range supports OEM.





| SUNDI- | 135 135W |
155 155W |
175 175W |
1A10 1A10W |
1A15 1A15W |
|
| Temp range | -10℃~+150℃ | |||||
| Medium temp accuracy | ±0.5℃ | |||||
| Material temp accuracy | ±1℃ | |||||
| Heating power | 3.5 | 5.5 | 7.5 | 10 | 15 | |
| Cooling capacity |
150℃ | 3.5 | 5.5 | 7.5 | 10 | 15 |
| 20℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | |
| -5℃ | 2.1 | 3.3 | 4.2 | 6 | 9 | |
| Flow、pressure max L/min bar |
35 | 35 | 50 | 50 | 75 | |
| 1 | 1 | 1.2 | 1.2 | 1.2 | ||
| Cooling water @20℃ |
1300L/H 1.5bar~4bar ZG1/2 |
1800L/H 1.5bar~4bar ZG3/4 |
1800L/H 1.5bar~4bar ZG3/4 |
2400L/H 1.5bar~4bar ZG3/4 |
3600L/H 1.5bar~4bar ZG1 |
|
| Dimension cm | 45*70*160 | 45*70*160 | 55*70*175 | 55*70*175 | 70*85*185 | |
| Power 380V 50HZ | 6.7kW | 9.5kW | 12kW | 15.5kW | 23kW | |
Type
SUNDI-10℃~150℃ chiller heater combo has two options: portable air chiller heater and portable water chiller heater.
Sustainability
SUNDI-10℃~150℃ portable chiller heater unit adopts environmentally friendly non-ozone depleting refrigerant, using R404A or R507C.
Fully closed circulation system
SUNDI-10℃~150℃ chiller heater unit adopts fully closed pipeline design, which does not absorb moisture at low temperature and does not volatilize the medium at high temperature.


Whether it is material testing, product development or precision production, accurate and stable temperature environment is crucial.
Chiller heater units can provide a suitable temperature environment for high-pressure reactors, double-layer glass reactors, double-layer reactors, microchannel reactors, etc.
Semiconductor/Electronic Manufacturing
The production, packaging, and testing of precision electronic components require simulation of different temperature conditions to ensure their performance stability.
Chiller heater combos are used for performance research of aircraft materials and temperature control during component testing.

Cooling capacity 2.1kW~15kW
Heating power 3.5kW~15kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 1.8kW~200kW
Heating power 3.5kW~200kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.25kW~200kW
Heating power 2.5kW~200kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.25kW~60kW
Heating power 2.5kW~60kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.3kW~80kW
Heating power 3kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.5kW~80kW
Heating power 5.5kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.7kW~80kW
Heating power 5.5kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.4kW~1.5kW
Heating power 2kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

WeChat/Phone
86 18914253067

+86 18914253067

Email Address
market@lneya.com

Served more than 30,000 customers.
Exported to more than 20 countries.

Has obtained CE certification, SGS certification, ISO certification.

Provide comprehensive technical training.
With 24/7 solutions.

Founded in 2010, with 15 years of industry experience.
20% of employees are technicians.

Visual inspection.
Performance test.
Electrical safety test.
Get in touch with our Chiller Heater Unit experts
Can’t find a suitable chiller heater unit?Contact us now to get details and prices
Contact LNEYA