| SUNDI – | 235 | 255 | 275 | 2A10 | 2A15 | 2A25 | 2A38W | 2A60W | 2A95W | 2A130W | 2A200W | |
| Temp range | -25℃~+200℃(can be -25℃~+300℃) | |||||||||||
| Medium temp accuracy | ±0.5℃ | |||||||||||
| Material temp accuracy | ±1℃ | |||||||||||
| Heating power | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
| Cooling | 200℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 |
| 100℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
| 50℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
| 20℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
| -5℃ | 3 | 4.5 | 6.3 | 8 | 11 | 19 | 30 | 46 | 70 | 80 | 125 | |
| -15℃ | 1.8 | 2.8 | 3.8 | 4.6 | 7 | 12 | 16 | 22 | 32 | 43 | 65 | |
| Flow、pressure max | 35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | 400 | 400 | 600 | |
| 1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
| Cooling water | 1500L/H 1.5bar~4bar |
1800L/H 1.5bar~4bar |
3000L/H 1.5bar~4bar |
4200L/H 1.5bar~4bar |
5400L/H 1.5bar~4bar |
10m³/H 1.5bar~4bar |
10m³/H 1.5bar~4bar |
14m³/H 1.5bar~4bar |
19m³/H 1.5bar~4bar |
24m³/H 1.5bar~4bar |
36m³/H 1.5bar~4bar DN80 |
|
| Dimension cm | 45*70*160 | 45*70*160 | 55*70*175 | 65*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*145*225 | 300*160*225 | |
| Power 380V 50HZ | 6.7kW | 9.5kW | 15kW | 16kW | 27kW | 48kW | 55kW | 81kW | 126kW | 175kW | 260kW | |
Wide temperature range
SUNDI-25℃~200℃ chiller heater has a very wide temperature range, from -25℃ to 200℃, so you don’t need to replace the chiller and medium during operation. We can design a process chiller with a temperature range of -150℃ to 350℃ according to your needs.
Accuracy
SUNDI-25℃~200℃ heating/cooling circulator can accurately control the temperature, with a temperature control accuracy of ±0.5℃ for the heat transfer medium and ±1℃ for the reaction material, providing you with production stability and repeatable results.
Fully enclosed design
SUNDI-25℃~200℃ chiller heater unit adopts a fully enclosed pipeline design. The heat transfer medium is in a closed system, and the heat transfer medium in the expansion vessel does not participate in the circulation, which effectively reduces the risk of the heat transfer medium absorbing moisture and volatilizing during the operation of the chiller.


Medical
SUNDI-25℃~200℃ heating/cooling circulator used in pretreatment and extract preparation, molecular short-range distillation solvent concentration and recovery, purification and crystallization control, solvent recovery and other process flows.
Drug research and development
Semiconductor manufacturing
Semiconductor processes such as lithography, etching, cleaning, packaging, and testing have high requirements for the stability and accuracy of temperature control.

Cooling capacity 2.1kW~15kW
Heating power 3.5kW~15kW

Cooling capacity 1.8kW~200kW
Heating power 3.5kW~200kW

Cooling capacity 0.25kW~200kW
Heating power 2.5kW~200kW

Cooling capacity 0.25kW~60kW
Heating power 2.5kW~60kW

Cooling capacity 0.3kW~80kW
Heating power 3kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.5kW~80kW
Heating power 5.5kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.7kW~80kW
Heating power 5.5kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.4kW~1.5kW
Heating power 2kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

WeChat/Phone
86 18914253067

+86 18914253067

Email Address
market@lneya.com

Served more than 30,000 customers.
Exported to more than 20 countries.

Has obtained CE certification, SGS certification, ISO certification.

Provide comprehensive technical training.
With 24/7 solutions.

Founded in 2010, with 15 years of industry experience.
20% of employees are technicians.

Visual inspection.
Performance test.
Electrical safety test.
Get in touch with our Heating / Cooling Circulator experts
Contact LNEYA
Submit your request to us and we will contact you within 24 hours