Search the whole station

Chillers and Heaters

SUNDI -60℃~+250℃

Cooling capacity 0.25kW~60kW
Heating power 2.5kW~60kW
Medium temp accuracy ±0.5℃
Energy are consumed

The temperature control range of this process chiller heater is -60℃~250℃, the temperature control accuracy of the heat transfer medium is ±0.5℃, and the temperature control accuracy of the reaction material is ±1℃, which meets your pursuit of temperature control stability and accuracy.

sundi series

-60°C

lowest

250°C

Highest

±0.5°C
±1℃

Temperature control accuracy

Medium & Material


SUNDI- 625
625W
635
635W
655
655W
675
675W
6A10
6A10W
6A15W 6A25W 6A38W 6A60W
Temp range  -60℃~+250℃
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃
Heating power 2.5 3.5 5.5 7.5 10 15 25 38 60
Cooling capacity 250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
-40℃ 0.95 1.45 2.3 3.1 4.8 7.8 18 23 31
-55℃ 0.25 0.5 0.75 0.9 1.5 2.8 6 8 11
Flow、pressuremax  L/min bar 20 35 35 50 60 110 150 200 250
1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5
Cooling water
@20℃
1100L/H
1.5bar~4bar
ZG1/2
2000L/H
1.5bar~4bar
ZG3/4
2300L/H
1.5bar~4bar
ZG3/4
2600L/H
1.5bar~4bar
ZG3/4
3300L/H
1.5bar~4bar
ZG1
4000L/H
1.5bar~4bar
ZG1 1/4
8.5m³/H
1.5bar~4bar
DN40
14m³/H
1.5bar~4bar
DN50
20m³/H
1.5bar~4bar
DN65
Dimension cm 55*70*175 55*70*175 55*70*175 65*85*185 65*85*185 80*120*185 150*100*185 200*145*205 200*145*205
Power 380V 50HZ 5kW 10kW 12kW 18kW 22kW 28kW 56kW 73kW 110kW
Portable air & water chiller

Three-point temperature control

20 programs can be compiled

The key to ensuring high precision and high efficiency

Advantages of Chillers and Heaters

Technological innovation
LNEYA invests at least 7% of its turnover in innovation and research and development each year, and currently has 90 patents. It is at the international leading level in the research and development of single-machine cascade refrigeration technology and single-medium temperature control of reactors.
 
Magnetic drive pump
SUNDI-60℃~250℃ chiller heaters are equipped with magnetic drive pumps. Since no mechanical seal is used, there is no shaft seal leakage problem, and you do not need to spend money to regularly check the pump for leakage or replace the mechanical seal.

The key to ensuring high precision and high efficiency

Chillers and Heaters Applications


Extraction
Extraction is a process of separating the target substance from a mixture through a solvent. The principle is that different components have different solubility in the solvent. The temperature needs to be strictly controlled during the extraction process to prevent the target component from decomposing at too high a temperature or incomplete reaction at too low a temperature. This requires the use of a chiller heater combo.

Distillation and rectification
In molecular distillation or azeotropic distillation, the refrigeration system and heating system of the process chiller heater respectively control the temperature of the condensation section and the heating section to help evaporate high-boiling substances and cool down to recover the target components.
 
Crystallization and recrystallization
SUNDI-60℃~250℃ chiller heater unit plays an important role in the crystallization process of chemicals. Accurate temperature control can regulate the growth rate of crystals and avoid impurities in the crystals. During the recrystallization process, rapid cooling can inhibit side reactions and improve crystal uniformity.

Other models for DYNAMIC TEMPERATURE CONTROL SYSTEMS

You can trust our portable chiller factory

We are a very powerful chiller supplier with our own factory and more than 20 years of experience in the field of temperature control

LNEYA has a professional design and R&D team, 90+ invention patents, and more than 15 years of production experience. Basic research such as simulation and thermal energy is provided by a doctoral team to provide guarantee for application technology, realizing the integration from selection, calculation, 3D, and drawings. It can be customized according to your requirements.

Global service

Served more than 30,000 customers.
Exported to more than 20 countries.

Certification patents

Has obtained CE certification, SGS certification, ISO certification.

After-sales service

Provide comprehensive technical training.
With 24/7 solutions.

Professional team

Founded in 2010, with 15 years of industry experience.
20% of employees are technicians.

Quality control

Visual inspection.
Performance test.
Electrical safety test.

Our main products include refrigeration and heating circulators, dynamic temperature control systems, freezers, semiconductor chillers, new energy test chillers and other equipment.