Add our account manager via the QR code below

WeChat/Phone
18914253067

+86 18914253067

Email Address
market@lneya.com
Search the whole station





| SUNDI- | 625 625W |
635 635W |
655 655W |
675 675W |
6A10 6A10W |
6A15W | 6A25W | 6A38W | 6A60W | |
| Temp range | -60℃~+250℃ | |||||||||
| Medium temp accuracy | ±0.5℃ | |||||||||
| Material temp accuracy | ±1℃ | |||||||||
| Heating power | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
| Cooling capacity | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 |
| 100℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
| 20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
| -40℃ | 0.95 | 1.45 | 2.3 | 3.1 | 4.8 | 7.8 | 18 | 23 | 31 | |
| -55℃ | 0.25 | 0.5 | 0.75 | 0.9 | 1.5 | 2.8 | 6 | 8 | 11 | |
| Flow、pressuremax L/min bar | 20 | 35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | |
| 1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | ||
| Cooling water @20℃ |
1100L/H 1.5bar~4bar ZG1/2 |
2000L/H 1.5bar~4bar ZG3/4 |
2300L/H 1.5bar~4bar ZG3/4 |
2600L/H 1.5bar~4bar ZG3/4 |
3300L/H 1.5bar~4bar ZG1 |
4000L/H 1.5bar~4bar ZG1 1/4 |
8.5m³/H 1.5bar~4bar DN40 |
14m³/H 1.5bar~4bar DN50 |
20m³/H 1.5bar~4bar DN65 |
|
| Dimension cm | 55*70*175 | 55*70*175 | 55*70*175 | 65*85*185 | 65*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | |
| Power 380V 50HZ | 5kW | 10kW | 12kW | 18kW | 22kW | 28kW | 56kW | 73kW | 110kW | |
Technological innovation
LNEYA invests at least 7% of its turnover in innovation and research and development each year, and currently has 90 patents. It is at the international leading level in the research and development of single-machine cascade refrigeration technology and single-medium temperature control of reactors.
Magnetic drive pump
SUNDI-60℃~250℃ chiller heaters are equipped with magnetic drive pumps. Since no mechanical seal is used, there is no shaft seal leakage problem, and you do not need to spend money to regularly check the pump for leakage or replace the mechanical seal.


Extraction
Extraction is a process of separating the target substance from a mixture through a solvent. The principle is that different components have different solubility in the solvent. The temperature needs to be strictly controlled during the extraction process to prevent the target component from decomposing at too high a temperature or incomplete reaction at too low a temperature. This requires the use of a chiller heater combo.
Distillation and rectification
In molecular distillation or azeotropic distillation, the refrigeration system and heating system of the process chiller heater respectively control the temperature of the condensation section and the heating section to help evaporate high-boiling substances and cool down to recover the target components.
Crystallization and recrystallization
SUNDI-60℃~250℃ chiller heater unit plays an important role in the crystallization process of chemicals. Accurate temperature control can regulate the growth rate of crystals and avoid impurities in the crystals. During the recrystallization process, rapid cooling can inhibit side reactions and improve crystal uniformity.

Cooling capacity 2.1kW~15kW
Heating power 3.5kW~15kW

Cooling capacity 1.8kW~200kW
Heating power 3.5kW~200kW

Cooling capacity 0.25kW~200kW
Heating power 2.5kW~200kW

Cooling capacity 0.25kW~60kW
Heating power 2.5kW~60kW

Cooling capacity 0.3kW~80kW
Heating power 3kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.5kW~80kW
Heating power 5.5kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.7kW~80kW
Heating power 5.5kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Cooling capacity 0.4kW~1.5kW
Heating power 2kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

WeChat/Phone
18914253067

+86 18914253067

Email Address
market@lneya.com

Served more than 30,000 customers.
Exported to more than 20 countries.

Has obtained CE certification, SGS certification, ISO certification.

Provide comprehensive technical training.
With 24/7 solutions.

Founded in 2010, with 15 years of industry experience.
20% of employees are technicians.

Visual inspection.
Performance test.
Electrical safety test.
Get in touch with our Water Chiller and Heaters experts
Contact LNEYA
Submit your request to us and we will contact you within 24 hours