UST Series
APPLICATIONS
Suitable for temperature control in more usage scenarios
Used with reactors, reactors, microchannels, distillation systems, etc., and also used for heating and cooling of other equipment. Widely used in pharmaceutical, chemical, biological, semiconductor, new materials and other industries
Product Features
Product Parameters
Model | UST-5530 UST-5530W | UST-7530 UST-7530W | UST-A1030 UST-A1030W | UST-A1530 UST-A1530W | UST-A2530 UST-A2530W | UST-A3830 UST-A3830W | UST-A6030 UST-A6030W | UST-A9530 UST-A9530W | |
Temp range | RT+10℃~+300℃ | ||||||||
Control system | Feedback PID + Our special dynamic control calculation, PLC controller | ||||||||
Control Mode | Process temp control and jacket temp control mode | ||||||||
Temp difference | Set or control the temperature difference between jacket oil and raw material process | ||||||||
Program Editor | 5 programs, each program can edit 40 steps | ||||||||
Communication protoco | MODBUS RTU Protocol,RS485 interface | ||||||||
Material temp feedback | PT100 OR 4~20mA or communication(normal: PT100) | ||||||||
Temp feedback | The temp of three points: the inlet and outlet of equipment, reactor material temperature(external temp sensor) | ||||||||
Medium temp acccuracy | ±0.5℃ | ±1℃ | |||||||
Material temp accuracy | ±1℃ | ||||||||
Heating power kW | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
Cooling capacity |
300 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 |
200 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
100 ℃ | 4 | 5 | 7 | 12 | 20 | 30 | 48 | 76 | |
65 ℃ | 1.8 | 2.2 | 3 | 5 | 8.5 | 12 | 19 | 30 | |
Circulation pump max L/min bar |
35 | 50 | 50 | 110 | 150 | 200 | 250 | 400 | |
2 | 2 | 2 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Operation Panel | 7-inch touch screen, show temp curve\EXCEL data output | ||||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, high temperature protection and temp fault protection |
||||||||
Closed circulation system |
The whole system is full closed circulation, there is no oil mist at high temp and no water vapor at low temp, pressure do not rise up when system is running. The system will supply oil automatically at low temperature |
||||||||
Connection siz | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Connection size(water port) | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Dimension cm | 40*70*130 | 45*70*160 | 40*70*160 | 70*100*175 | 70*100*175 | 80*120*185 | 150*100*185 | 200*145*205 | |
Weight kg | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 950 | |
Power MAX 380V 50HZ |
7kW | 9kW | 12kW | 17kW | 28kW | 41kW | 65kW | 96kW | |
Shell materia | Cold rolled sheet (REL7035) |
contact us