UC/LY Series Heating Circulators
APPLICATIONS
- Heating Circulator UC series with function from high temperature to cooling process, from 300℃~50℃.
- Equipped with heating cooling container, with large heat transfer area, fast heat-up and cool-down, small heat transfer oil demand.
- Can heat-up and cool-down continuously.
- The whole cycle is full closed,there is no oil mist at high temperature, heat transfer oil can not be oxidized and browning.
- With function of internal PT100 for correcting internal circulation.
- The whole system is closed with expansion tank, the expansion tank and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in expansion tank is limited to 60℃.
Product Features
Product Parameters
UC 50℃~300℃
Model | UC-5530N | UC-7530N | UC-A1030N | UC-A1530N | UC-A2530N | UC-A3830N | UC-A6030N | UC-A9530N | UC-A13030N | |
Temp range | 50℃~300℃ | |||||||||
Controller | PID adaptive controller | |||||||||
Temp control | Heat-conducting medium outlet temp. control | |||||||||
Display/Record | 7-inch color touch screen,recording temperature curve,data export using excel format | |||||||||
Temp feedback | 导Heat-conducting medium temperature feedback Pt100 | |||||||||
Temp accuracy | ±0.5℃ | |||||||||
Heating power KW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | |
Cooling Capacity kW at |
300℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW |
200℃ | 5..5kW | 7.5kW | 10kW | 13kW | 25kW | 38kW | 60kW | 95kW | 130kW | |
100℃ | 4kW | 5kW | 7kW | 12kW | 20kW | 30kW | 48kW | 76kW | 100kW | |
65℃ | 1.8kW | 2.2kW | 3kW | 5kW | 8.5kW | 12kW | 19kW | 30kW | 40kW | |
Criculation pump flow |
Max35L/min 1.2BAR | Max50L/min 1.2BAR | Max50L/min 1.2BAR | Max110L/min 1.5BAR | Max150L/min 1.5BAR | Max200L/min 1.5BAR | Max250L/min 2.5BAR | Max400L/min 2.5BAR | Max400L/min 2.5BAR | |
Heater | Flanged pipe electric heater | |||||||||
Independent temp. limite | Lneya | |||||||||
Cooler | Copper Tube Aluminum Fin air-cooled Condenser | Plate heat exchanger/Tube heat exchanger | ||||||||
Safety Protection | Self-diagnosis function; freezer overload protection; high pressure switch; overload relay; thermal protection device and other safety protection |
|||||||||
Closed Circulation System |
The whole system is a full closed circulation, there is No oil mist at high temperature,pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. |
|||||||||
Connection size | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | DN50 PN10 | |
Dimension cm | 40*70*130 | 45*70*160 | 45*70*160 | 70*100*175 | 70*100*175 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | |
Weight kg | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 1220 | 1400 | |
Power max AC 380V 50HZ |
7kW | 9kW | 12kW | 17kW | 28kW | 41kW | 65kW | 101kW | 136kW | |
Case material | Cold rolled sheet (REL7035) | |||||||||
Optional | 220V 60HZ three phase,440V~460V 80HZ three phase |
LY 50℃~170℃
Model | LY-5020 | LY-A020 | UC-5020 | UC-A1020 | UC-A1520 | |
Temp range | 50℃~170℃ | |||||
Controller | PID adaptive controller | |||||
Tempcontrol | Heat-conducting medium outlet temp. control | |||||
Temp feedback | Heat-conducting medium temperature feedback Pt100 | |||||
Temp accuracy | ±0.5℃ | |||||
Heating power KW | 5.5kW | 10kW | 5.5kW | 10kW | 15kW | |
Cooling Capacity kW at |
170℃ | 5.5kW | 10kW | 15kW | ||
100℃ | 4kW | 8kW | 12kW | |||
65℃ | 1.8kW | 3.4kW | 5kW | |||
Criculation pump flow |
35L/min 1.5BAR | 50L/min 1.5BAR | 35L/min 1.5BAR | 50L/min 1.5BAR | 50L/min 1.5BAR | |
Heater | Flanged pipe electric heater | |||||
Independent temp. limite | Rainbow temperature protector | |||||
Cooler | Copper Tube Aluminum Fin air-cooled Condenser | Plate heat exchanger | ||||
Operation panel | Display set temperature and measured temperature,key operation input temperature | |||||
Safety Protection | overload relay、variety of security features such as thermal protection devices | |||||
Closed Circulation System |
The whole system is a full closed circulation, there is No oil mist at high temperature,pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. |
|||||
Connection size | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | |
Dimension cm | 40*70*130 | 40*70*130 | 40*70*130 | 40*70*130 | 70*100*175 | |
Weight kg | 70kg | 80kg | 78kg | 128kg | 170kg | |
Power max AC 380V 50HZ |
6kW | 11kW | 6kW | 11kW | 16kW | |
Case material | Cold rolled sheet (REL7035) | |||||
Optional | Optional 7-inch color touch screen,recording temperature curve,data export using excel format | |||||
Optional | SUS304 shell | |||||
Optional | 220V 60HZ three phase,440V~460V 80HZ three phase |
contact us