UC/LY Series Heating Circulators
APPLICATIONS
- Heating Circulator UC series with function from high temperature to cooling process, from 300℃~50℃.
- Equipped with heating cooling container, with large heat transfer area, fast heat-up and cool-down, small heat transfer oil demand.
- Can heat-up and cool-down continuously.
Product Features
Product Parameters
UC 50℃~300℃
Model | UC-5530N | UC-7530N | UC-A1030N | UC-A1530N | UC-A2530N | UC-A3830N | UC-A6030N | UC-A9530N | UC-A13030N | |
Temp range | 50℃~300℃ | |||||||||
Controller | PID adaptive controller | |||||||||
Temp control | Heat-conducting medium outlet temp. control | |||||||||
Display/Record | 7-inch color touch screen,recording temperature curve,data export using excel format | |||||||||
Temp feedback | 导Heat-conducting medium temperature feedback Pt100 | |||||||||
Temp accuracy | ±0.5℃ | |||||||||
Heating power KW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | |
Cooling Capacity kW at |
300℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW |
200℃ | 5..5kW | 7.5kW | 10kW | 13kW | 25kW | 38kW | 60kW | 95kW | 130kW | |
100℃ | 4kW | 5kW | 7kW | 12kW | 20kW | 30kW | 48kW | 76kW | 100kW | |
65℃ | 1.8kW | 2.2kW | 3kW | 5kW | 8.5kW | 12kW | 19kW | 30kW | 40kW | |
Criculation pump flow |
Max35L/min 1.2BAR | Max50L/min 1.2BAR | Max50L/min 1.2BAR | Max110L/min 1.5BAR | Max150L/min 1.5BAR | Max200L/min 1.5BAR | Max250L/min 2.5BAR | Max400L/min 2.5BAR | Max400L/min 2.5BAR | |
Heater | Flanged pipe electric heater | |||||||||
Independent temp. limite | Lneya | |||||||||
Cooler | Copper Tube Aluminum Fin air-cooled Condenser | Plate heat exchanger/Tube heat exchanger | ||||||||
Safety Protection | Self-diagnosis function; freezer overload protection; high pressure switch; overload relay; thermal protection device and other safety protection |
|||||||||
Closed Circulation System |
The whole system is a full closed circulation, there is No oil mist at high temperature,pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. |
|||||||||
Connection size | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | DN50 PN10 | |
Dimension cm | 40*70*130 | 45*70*160 | 45*70*160 | 70*100*175 | 70*100*175 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | |
Weight kg | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 1220 | 1400 | |
Power max AC 380V 50HZ |
7kW | 9kW | 12kW | 17kW | 28kW | 41kW | 65kW | 101kW | 136kW | |
Case material | Cold rolled sheet (REL7035) | |||||||||
Optional | 220V 60HZ three phase,440V~460V 80HZ three phase |
LY 50℃~170℃
Model | LY-5020 | LY-A020 | UC-5020 | UC-A1020 | UC-A1520 | |
Temp range | 50℃~170℃ | |||||
Controller | PID adaptive controller | |||||
Tempcontrol | Heat-conducting medium outlet temp. control | |||||
Temp feedback | Heat-conducting medium temperature feedback Pt100 | |||||
Temp accuracy | ±0.5℃ | |||||
Heating power KW | 5.5kW | 10kW | 5.5kW | 10kW | 15kW | |
Cooling Capacity kW at |
170℃ | 5.5kW | 10kW | 15kW | ||
100℃ | 4kW | 8kW | 12kW | |||
65℃ | 1.8kW | 3.4kW | 5kW | |||
Criculation pump flow |
35L/min 1.5BAR | 50L/min 1.5BAR | 35L/min 1.5BAR | 50L/min 1.5BAR | 50L/min 1.5BAR | |
Heater | Flanged pipe electric heater | |||||
Independent temp. limite | Rainbow temperature protector | |||||
Cooler | Copper Tube Aluminum Fin air-cooled Condenser | Plate heat exchanger | ||||
Operation panel | Display set temperature and measured temperature,key operation input temperature | |||||
Safety Protection | overload relay、variety of security features such as thermal protection devices | |||||
Closed Circulation System |
The whole system is a full closed circulation, there is No oil mist at high temperature,pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. |
|||||
Connection size | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | |
Dimension cm | 40*70*130 | 40*70*130 | 40*70*130 | 40*70*130 | 70*100*175 | |
Weight kg | 70kg | 80kg | 78kg | 128kg | 170kg | |
Power max AC 380V 50HZ |
6kW | 11kW | 6kW | 11kW | 16kW | |
Case material | Cold rolled sheet (REL7035) | |||||
Optional | Optional 7-inch color touch screen,recording temperature curve,data export using excel format | |||||
Optional | SUS304 shell | |||||
Optional | 220V 60HZ three phase,440V~460V 80HZ three phase |