KRY Multi-channel Series Battery Testing Thermal Control Solutions
APPLICATIONS
Control temperature & flow system supports one to many, meaning that one refrigeration and heating temperature control flow host can control 2-6 different test benches or demand temperature control flow devices. Support two one to many modes, one is that temperature/flow/pressure can be independently controlled (T-series), and the other is that temperature is consistent across multiple groups, and flow/pressure is independently controlled (S-series).(LNEYA’s chiller supports both indoor and outdoor options.)
Product Features
Product Parameters
Model | KRY-475/2T KRY-475W/2T |
KRY-4A15W/2T | KRY-4A25W/2T | KRY-4A38W/2T | KRY-4A60W/2T | |
Temp Range | -40℃~+100℃ | |||||
Temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Temp feedback | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | |
Temp display | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | |
Flow control accuracy/Group | 1~25 L/min | 1~40 L/min | 1~40 L/min | 1~40 L/min | 1~40 L/min | |
Flow rate accuracy/group | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | |
Number of fuid output groups | 2 groups | 2 groups | 2 groups | 2 groups | 2 groups | |
Pressure control/group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
Flow pressure description | The unit can control the flow individually or separately. Need to control different solutions at the same time (customized) | |||||
Heating capacity | 7.5kW*2 | 10kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | |
Cooling capacity | 100℃ | 7.5kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 |
20℃ | 7.5kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 | |
0℃ | 7.5kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 | |
-20℃ | 4.5kW*2 | 8.5kW*2 | 14kW*2 | 22kW*2 | 35kW*2 | |
-35℃ | 1.8kW*2 | 4kW*2 | 6.5kW*2 | 10kW*2 | 15kW*2 | |
Compressor | Emerson Copeland | |||||
Throttle type | Electronic expansion valve | |||||
Oil separator | Emerson/GUANYA | |||||
Dry filter | Danfoss | |||||
Evaporator | Plate heat exchanger | |||||
Circulation pump | Magnetic driven pump | |||||
Flow pressure | Electromagnetic flowmeter, pressure value 4~20mA | |||||
Input display | 7-inch color touch screen \ PLC controller | |||||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions | |||||
Closed circulation system | The whole system is a fully closed system, there will be no oil mist at high temperature, the system in operation will not because of high temperature pressure rise, low temperature automatically add heat conduction medium |
|||||
Refrigerant | R404A/R507C/R125/N40All four refrigerants are available | |||||
Connection size | There are 2 groups of inlet and outlet, ZG3/4 | |||||
Water-cooled type Wat 20度 | 4000L/H ZG1 |
8000L/H DN32 |
12000L/H DN40 |
20000L/H DN50 |
30000L/H DN65 |
|
Condenser(W) | Condenser adopts plate heat exchanger, so please use chiller to provide cooling water or low hardness tap water | |||||
Dimension cm | 28kW | 45kW | 70kW | 108kW | 158kW | |
水冷尺寸cm | 80*100*185 | 100*150*185 | 200*145*205 | 200*145*205 | 250*145*225 | |
Weight | 660KG | 850kg | 1350kg | 1800kg | 2600kg | |
Optional | 220V 60HZ Three phase 460V 60HZ Three phase | |||||
Optional | Extend to -40~+135℃ | |||||
Optional | Automatic liquid recovery system | |||||
Case material | Cold rolled sheet (REL7035) |
Model | KRY-A25W/6S | KRY-A38W/6S | KRY-A60W/6S | |
Temp Range | 0℃~+100℃ | |||
Temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Temp feedback | Pt100 | Pt100 | Pt100 | |
Temp display | 0.01k | 0.01k | 0.01k | |
Flow control accuracy/Group | 2~25 L/min | 2~25 L/min | 2~25 L/min | |
Flow rate accuracy/group | ±0.2L/min | |||
Number of fuid output groups | 6 groups | 6 groups | 6 groups | |
Pressure control/group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
Flow pressure description | The unit can control the flow individually or separately. Need to control different solutions at the same time (customized) | |||
Heating capacity | 15kW | 25kW | 38kW | |
Cooling capacity | 100℃ | 25kW | 38kW | 60kW |
20℃ | 25kW | 38kW | 60kW | |
5℃ | 18kW | 27kW | 42kW | |
Compressor | Brand Copeland | |||
Throttle type | Electronic expansion valve | |||
Oil separator | Emerson/GUANYA | |||
Dry filter | Danfoss | |||
Evaporator | Plate heat exchanger | |||
Circulation pump | Centrifugal pump, optional magnetic drive pump | |||
Flow pressure | Electromagnetic flowmeter, pressure value 4~20mA | |||
Input display | 7-inch color touch screen \ PLC controller | |||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions | |||
Refrigerant | R410A | |||
Connection size | There are six groups of inlet and outlet, ZG3/4 | |||
Water-cooled type @ 20℃ | 6000L/H DN32 |
9000L/H DN40 |
15000L/H DN50 |
|
Condenser(W) | Shenshi tube type heat exchanger | |||
Power 380V50HZ | 38kW | 55kW | 82kW | |
Dimension cm | 200*145*205 | 200*145*205 | 200*145*205 | |
Weight | 900kg | 1200kg | 1950kg | |
Optional | The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load,pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp, liquid low level protection |
|||
Optional | 220V 60HZ three-phase 460V 60HZ three-phase | |||
Optional | Higher precision control of temperature, flow rate, and pressure | |||
Optional | Number of fuid output groups | |||
Optional | Automatic antifreeze system | |||
Optional | Automatic liquid recovery system | |||
Case material | Cold rolled sheet (REL7035) |
Model | KRY-475/2T KRY-475W/2T |
KRY-4A15W/2T | KRY-4A25W/2T | KRY-4A38W/2T | KRY-4A60W/2T | |
Temp Range | -40℃~+100℃ | |||||
Temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Temp feedback | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | |
Temp display | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | |
Flow control accuracy/Group | 1~25 L/min | 1~40 L/min | 1~40 L/min | 1~40 L/min | 1~40 L/min | |
Flow rate accuracy/group | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | |
Number of fuid output groups | 2 groups | 2 groups | 2 groups | 2 groups | 2 groups | |
Pressure control/group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
Flow pressure description | The unit can control the flow individually or separately. Need to control different solutions at the same time (customized) | |||||
Heating capacity | 7.5kW*2 | 10kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | |
Cooling capacity | 100℃ | 7.5kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 |
20℃ | 7.5kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 | |
0℃ | 7.5kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 | |
-20℃ | 4.5kW*2 | 8.5kW*2 | 14kW*2 | 22kW*2 | 35kW*2 | |
-35℃ | 1.8kW*2 | 4kW*2 | 6.5kW*2 | 10kW*2 | 15kW*2 | |
Compressor | Emerson Copeland | |||||
Throttle type | Electronic expansion valve | |||||
Oil separator | Emerson/GUANYA | |||||
Dry filter | Danfoss | |||||
Evaporator | Plate heat exchanger | |||||
Circulation pump | Magnetic driven pump | |||||
Flow pressure | Electromagnetic flowmeter, pressure value 4~20mA | |||||
Input display | 7-inch color touch screen \ PLC controller | |||||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions | |||||
Closed circulation system | The whole system is a fully closed system, there will be no oil mist at high temperature, the system in operation will not because of high temperature pressure rise, low temperature automatically add heat conduction medium |
|||||
Refrigerant | R404A/R507C/R125/N40All four refrigerants are available | |||||
Connection size | There are 2 groups of inlet and outlet, ZG3/4 | |||||
Water-cooled type Wat 20度 | 4000L/H ZG1 |
8000L/H DN32 |
12000L/H DN40 |
20000L/H DN50 |
30000L/H DN65 |
|
Condenser(W) | Condenser adopts plate heat exchanger, so please use chiller to provide cooling water or low hardness tap water | |||||
Dimension cm | 28kW | 45kW | 70kW | 108kW | 158kW | |
水冷尺寸cm | 80*100*185 | 100*150*185 | 200*145*205 | 200*145*205 | 250*145*225 | |
Weight | 660KG | 850kg | 1350kg | 1800kg | 2600kg | |
Optional | 220V 60HZ Three phase 460V 60HZ Three phase | |||||
Optional | Extend to -40~+135℃ | |||||
Optional | Automatic liquid recovery system | |||||
Case material | Cold rolled sheet (REL7035) |
Model | KRY-475/2T KRY-475W/2T |
KRY-4A15W/2T | KRY-4A25W/2T | KRY-4A38W/2T | KRY-4A60W/2T | |
Temp Range | -40℃~+100℃ | |||||
Temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Temp feedback | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | |
Temp display | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | |
Flow control accuracy/Group | 1~25 L/min | 1~40 L/min | 1~40 L/min | 1~40 L/min | 1~40 L/min | |
Flow rate accuracy/group | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | |
Number of fuid output groups | 2 groups | 2 groups | 2 groups | 2 groups | 2 groups | |
Pressure control/group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
Flow pressure description | The unit can control the flow individually or separately. Need to control different solutions at the same time (customized) | |||||
Heating capacity | 7.5kW*2 | 10kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | |
Cooling capacity | 100℃ | 7.5kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 |
20℃ | 7.5kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 | |
0℃ | 7.5kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 | |
-20℃ | 4.5kW*2 | 8.5kW*2 | 14kW*2 | 22kW*2 | 35kW*2 | |
-35℃ | 1.8kW*2 | 4kW*2 | 6.5kW*2 | 10kW*2 | 15kW*2 | |
Compressor | Emerson Copeland | |||||
Throttle type | Electronic expansion valve | |||||
Oil separator | Emerson/GUANYA | |||||
Dry filter | Danfoss | |||||
Evaporator | Plate heat exchanger | |||||
Circulation pump | Magnetic driven pump | |||||
Flow pressure | Electromagnetic flowmeter, pressure value 4~20mA | |||||
Input display | 7-inch color touch screen \ PLC controller | |||||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions | |||||
Closed circulation system | The whole system is a fully closed system, there will be no oil mist at high temperature, the system in operation will not because of high temperature pressure rise, low temperature automatically add heat conduction medium |
|||||
Refrigerant | R404A/R507C/R125/N40All four refrigerants are available | |||||
Connection size | There are 2 groups of inlet and outlet, ZG3/4 | |||||
Water-cooled type Wat 20度 | 4000L/H ZG1 |
8000L/H DN32 |
12000L/H DN40 |
20000L/H DN50 |
30000L/H DN65 |
|
Condenser(W) | Condenser adopts plate heat exchanger, so please use chiller to provide cooling water or low hardness tap water | |||||
Dimension cm | 28kW | 45kW | 70kW | 108kW | 158kW | |
水冷尺寸cm | 80*100*185 | 100*150*185 | 200*145*205 | 200*145*205 | 250*145*225 | |
Weight | 660KG | 850kg | 1350kg | 1800kg | 2600kg | |
Optional | 220V 60HZ Three phase 460V 60HZ Three phase | |||||
Optional | Extend to -40~+135℃ | |||||
Optional | Automatic liquid recovery system | |||||
Case material | Cold rolled sheet (REL7035) |
Difference between single channel and multi-channel

Conventional Equipment
Temp. control
Pressure control
Flow control
Multiple Device Connection (T)
Temp. control
Pressure control
Flow control
Multiple Device Connection (S)
Consistent temp. control
Pressure control
Flow control

Adopts LNEYA PLC control, simple menu navigation, 7" color large screen, multi-faceted and multi-functional images to display comprehensive important data information. The newly added safety measures ensure continuous unattended operation. All relevant operating status data are continuously monitored and visualized on the touch screen. Supports one-to-many multi-channel independent control, and each group can be set independently.
Suitable for more simulation test temperature control
Equipment application: new energy battery pack, battery module, battery cell, motor and controller, charger, DC/DC converter, electronic pump

Why choose lneya as your temperature control supplier?
Years of experience
Satisfied Customers
m² Production Area
Patented Technologies
Visit LNEYA factory
contact us
Submit your request to us and we will contact you within 24 hours
Recommend Products
contact us
Submit your request to us and we will contact you within 24 hours