KRY Series Cooling Heating Control Temp & Flow System
APPLICATIONS
The object under test is connected to a test platform adapter, and the component is cooled and heated by ethylene glycol water solution inside the component. The tested component needs to undergo a specific temperature change curve, and the temperature change is recorded. The temperature change usually ranges from -40℃ to 100℃. (Extended to 150°C) When conducting tolerance tests, they are usually performed in cycles.
Product Features
Product Parameters
Model | KRY-455 KRY-455W |
KRY-475 KRY-475W |
KRY-4A10 KRY-4A10W |
KRY-4A15 KRY-4A15W |
KRY-4A25 KRY-4A25W |
KRY-4A38W | KRY-4A60W | |
Temp Range | -40℃~+100℃ | |||||||
Temp control accuracy | ±0.3℃ | |||||||
Temp feedback | Pt100 | |||||||
Temp display | 0.01k | |||||||
Flow rate output | 1~25 L/min | 1~25 L/min | 1~25 L/min | 1~40 L/min | 1~40 L/min | 1~40 L/min | 1~40 L/min | |
Flow rate accuracy | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | |
Heating capacity | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
Cooling capacity | 100℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW |
20℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
0℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
-20℃ | 2.8kW | 4.5kW | 6kW | 10kW | 16kW | 25kW | 35kW | |
-35℃ | 1.2kW | 1.8kW | 2.5kW | 4kW | 6.5kW | 10kW | 15kW | |
Connection size | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | |
Water-cooled type @25℃ | 1900L/H ZG3/4 |
2500L/H ZG3/4 |
3000L/H ZG1 |
4000L/H ZG1 |
6000L/H DN32 |
9000L/H DN40 |
15000L/H DN50 |
|
Power 380V50HZ | 10kW | 14kW | 17kW | 25kW | 38kW | 58kW | 84kW | |
Dimension cm | 55*100*175 | 55*100*175 | 70*100*175 | 80*120*185 | 100*150*185 | 100*150*185 | 200*145*205 | |
Weight | 250kg | 280kg | 320kg | 360kg | 620kg | 890kg | 1300KG | |
Optional | Extend to -40~+135℃ |
All equipment rated test conditions: dry bulb temperature: 20℃; wet bulb temperature: 16℃. Inlet water temperature: 20℃; outlet water temperature: 25℃.
Model | KRY-255 KRY-255W |
KRY-275 KRY-275W |
KRY-2A10 KRY-2A10W |
KRY-2A15 KRY-2A15W |
KRY-2A25 KRY-2A25W |
KRY-2A38W | |
Temp Range | -20℃~+100℃ | ||||||
Temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Temp feedback | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | |
Temp display | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | |
Flow rate output | 1~15 L/min | 1~25 L/min | 1~30 L/min | 1~40 L/min | 1~40 L/min | 1~40 L/min | |
Flow rate accuracy | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | |
Heating capacity | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | |
Cooling capacity | 100℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW |
20℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | |
0℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | |
-15℃ | 2.8kW | 3.8kW | 4.6kW | 7kW | 12kW | 16kW | |
Connection size | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | |
Water-cooled type W at 25℃ | 1900L/H ZG3/4 |
2500L/H ZG3/4 |
3000L/H ZG1 |
4000L/H ZG1 |
6000L/H DN32 |
9000L/H DN40 |
|
Power 380V50HZ | 11kW | 14kW | 19kW | 23kW | 31kW | 45kW | |
Dimension cm | 55*100*175 | 55*100*175 | 70*100*175 | 80*120*185 | 100*150*185 | 100*150*185 | |
Weight | 230kg | 250kg | 300kg | 320kg | 570kg | 830kg | |
Optional | Extend to -40~+135℃ |
Model | KRY-25 | KRY-55 | KRY-75 | KRY-A10 | KRY-A15 KRY-A15W |
KRY-A25 KRY-A25W |
KRY-A38W | KRY-A60W | |
Temp Range | 0℃~+100℃ | ||||||||
Temp control accuracy | ±0.3℃ | ||||||||
Temp feedback | Pt100 | ||||||||
Temp display | 0.01k | ||||||||
Flow rate output | 2~20 L/min | 2~25 L/min | 2~25 L/min | 2~25 L/min | 2~25 L/min | 2~25 L/min | 5~50 L/min | 5~50 L/min | |
Flow rate accuracy | ±0.2 L/min | ||||||||
Heating capacity | 2.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 15kW | 25kW | 38kW | |
Cooling capacity | 100℃ | 2.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW |
20℃ | 2.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
5℃ | 1.8kW | 3.8kW | 5.2kW | 7kW | 11kW | 18kW | 27kW | 42kW | |
Connection size | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | |
Water-cooled type W @25℃ | 3200L/H ZG1 |
6000L/H G1 1/4 |
9000L/H DN40 |
15000L/H DN50 |
|||||
Power 380V50HZ | 4.5kW220V | 8.5kW | 11.5kW | 16kW | 18kW | 28kW | 40kW | 61kW | |
Dimension cm | 50*85*145 | 55*100*175 | 55*100*175 | 70*100*175 | 80*120*185 | 100*150*185 | 100*150*185 | 100*150*185 | |
Weight | 220kg | 250kg | 280kg | 320kg | 360kg | 620kg | 890kg | 1300KG |
Difference between single channel and multi-channel

Conventional Equipment
Temp. control
Pressure control
Flow control
Multiple Device Connection (T)
Temp. control
Pressure control
Flow control
Multiple Device Connection (S)
Consistent temp. control
Pressure control
Flow control

Adopts LNEYA PLC control, simple menu navigation, 7" color large screen, multi-faceted and multi-functional images to display comprehensive important data information. The newly added safety measures ensure continuous unattended operation. All relevant operating status data are continuously monitored and visualized on the touch screen. Supports one-to-many multi-channel independent control, and each group can be set independently.
Suitable for more simulation test temperature control
Equipment application: new energy battery pack, battery module, battery cell, motor and controller, charger, DC/DC converter, electronic pump

Why choose lneya as your temperature control supplier?
Years of experience
Satisfied Customers
m² Production Area
Patented Technologies
Visit LNEYA factory