Search the whole station

Chemical Medium Temperature Control Chiller

Chemical Medium Temperature Control Chiller

APPLICATIONS

This CHILLER can directly introduce chemical media and accurately control the temperature, as a preheating and precooling temperature control for the medium before the chemical reaction; chemical media such as hydrofluoric acid, sulfuric acid, ammonia, nitric acid, ozone water, hydrochloric acid, sodium hydroxide, etc., need to confirm whether the concentration and temperature are met.

Product Features

Model ZLT-1HED
ZLT-1WHED
ZLT-3HED
ZLT-3WHED
ZLT-6HED
ZLT-6WHED
Temperature control 10 ℃~+60℃  Different media, different temperatures
Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃
Cooling capacity 20℃ 1kW 3kW 6kW
Heating 2kw 3.5kw 7.5kw
Direct cooling method Compressor
Input, Display 4.3 inch/7 inch color touch screen\PLC controller
Communication Modbus RTU protocol RS485 interface, Ethernet TCP/IP protocol
Heat exchanger Silicon carbide
Interface size G3/8 G3/8 G1/2
Water-cooled type @20℃ 300L/H 800L/H 1500L/H
G3/8 G3/8 G1/2
Water-cooled condenser Water-cooled equipment condenser adopts plate heat exchanger
Air-cooled condenser Microchannel heat exchanger
Power supply Single phase 220V Three-phase 380V/220V
Chemical pipe material PFA
Casing material Cold rolled plate spraying (REL7035)

 

All equipment rated test conditions: dry bulb temperature: 20℃; wet bulb temperature: 16℃. Inlet water temperature: 20℃; outlet water temperature: 25℃.

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

1. Displays all the kind of process control temperatures.
2. Shows the liquid level of the heat conducting medium in the expansion vessel.
3. Shows indication for refrigeration system working.
4. Shows indication for heater working.
5. Shows indication for circulation pump working.
6. Displays the temp. control ( materials temp. control pattern, heat conducting medium temp. control ).
7. The temp. upper limit, lower limit control can be set.
8. The temp. difference between jacket & reactor material can be set.
9. Shows the alarm to add the liquid when it is empty.
10. The refrigeration compressor can be set to operate manuallyor automatically.

APPLICATIONS

New materials | Special gas production temperature control

API | intermediate production temp control solution

Distillation concentration temperature control solution

Learn more

Learn more
*
*
Submitting....
Submitted successfully!
Submission failed! Please try again later
Email error!
Phone error!