LNEYA super deep crying treatment using common sense

For ultra-deep cold processing equipment, failure to pay attention to the use of the equipment may cause equipment failure.

Before using the water-cooled ultra-cry cryogenic treatment, it should be checked whether all the valves between the equipments are open, whether all the water tanks are filled with water, whether the fans are reversed, and whether the circulating water pump is running in the correct direction. Open the super deep crying treatment main power supply (the standard power supply is 3-phase five-wire system 380V 50HZ), specifically the water-cooled ultra-deep cold treatment front nameplate. Wuxi Guanya LNEYA reminds everyone that the power supply for ultra-deep cooling must be stable to avoid burning the unit or compressor and pump motor.

First open the ultra-deep cooling treatment cooling switch, then turn on the chilled water pump switch. Since the compressor has a delayed start function, the compressor will automatically run after the delay. At this time, pay close attention to the front control panel to observe the temperature change, as appropriate according to the cooling demand. Perform temperature adjustment. Water-cooled ultra-cry cryogenic treatment During normal operation, the unit operation data should be recorded periodically to facilitate the identification of problems based on data as soon as the unit fails. The ultra-cryogenic treatment itself is provided with multiple protection devices. Once there is a fault, it will start to protect and automatically stop. After the fault is removed, press the reset to operate normally.

When the super-cryogenic treatment is not used, the unit, water pump, insulated water tank and water in the pipeline should be drained, and the equipment should be covered and protected to avoid dust and other debris. Regarding the maintenance of ultra-deep cold treatment, this cannot be ignored. It is necessary to clean the condenser and evaporator after running for half a year. It is recommended to carry out maintenance of the whole machine after one year of operation, and keep it clean and clean regularly.

The instruction manual of the ultra-cryogenic treatment equipment and regular inspection and maintenance are all parts that the user needs to know in order to make the equipment run more efficiently.
Related News
  • LNEYA Is Exhibiting At Achema 2018

    LNEYA Is Exhibiting At Achema 2018

    January 11, 2018​The LNEYA Group will participate in the ACHEMA -World Forum and Leading Show for the Process Industries,Frankfurt am Main, Germany.view
  • Approaching LNEYA 5 Main Products

    Approaching LNEYA 5 Main Products

    January 11, 2018Industrial Chiller:Industrial Chiller varies from dynamic temp. Special Chiller:Special Chiller consist of Multi-reactor chiller (TCU).Environmental Chamber:The test object is connected to a testing adapter. Industrial Freezer:Industrial freezer consist oview
  • The Analysis Of Ultra Low Freezer'S Price

    The Analysis Of Ultra Low Freezer'S Price

    July 4, 2018What are the characteristics and functions of ultra low freezer: 1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the proce...view
  • The Application of Cold Plate Freezer

    The Application of Cold Plate Freezer

    July 4, 2018The refrigeration system of cold plate freezer adopts secondary super-cooler technology with the rapid refrigeration and low limiting temperature. It uses imported brand name semi-hermetic piston comp...view
  • 2018 Automotive Testing Expo

    2018 Automotive Testing Expo

    September 11, 2018Automotive Testing Expo 9.25-9.27view
  • The Analysis Of How To Maintain The Low Temperature Circulator In Daily Life

    The Analysis Of How To Maintain The Low Temperature Circulator In Daily Life

    July 4, 2018Guanya is a leading role in heating cooling circulator. It provides the customers with proposal and technology of controlling the cold and heat, temperature control system with stable property, extend...view
Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • LT -45℃~30℃

    LT -45℃~30℃

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
  • TES -45℃~250℃

    TES -45℃~250℃

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • TES -85℃~200℃

    TES -85℃~200℃

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view
products
Contact
Tel: + 86 18751546043
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat