About high and low temperature cycle machine refrigerant selection instructions
In the operation of high and low temperature cycle machines, the presence of refrigerant is essential, and the environmentally friendly mixed refrigerant used by LNEYA is better in terms of performance.
The high and low temperature cycle machine has a higher critical temperature and can undergo a phase change at normal temperature or normal low temperature, which is a basic requirement for the refrigerant in the steam high and low temperature cycle machine. High and low temperature cycle refrigerant suitable for saturated vapor pressure. Do not lower the evaporation pressure below atmospheric pressure to prevent air from leaking into the refrigeration system. The condensing pressure should not be too high to avoid excessive increase of high and low temperature cycle machines and equipment. At the same time, the ratio of the condensing pressure to the evaporation pressure should not be too large, so that the gas temperature is too high at the end of the compression and the gas transmission coefficient of the compressor is lowered.
The refrigerant solidification temperature is low to prevent the refrigerant from solidifying at the evaporation temperature. The viscosity and density are small to reduce the flow resistance loss of the refrigeration system. The high-temperature cycle machine has a high thermal conductivity to increase the heat transfer coefficient of the heat exchanger and reduce the heat transfer area and metal material consumption.
The refrigerant adiabatic index is small, which can reduce the power consumption of the compression process. At the end of the compression, the gas temperature is not too high, and the liquid heat capacity is small. The loss of the throttling process can be reduced, and the thermal perfection of the cycle is as large as possible. It does not burn, does not explode, is non-toxic, does not corrode to metal, does not have chemical action with lubricating oil, does not decompose under high temperature and is harmless to human body.
There are many types of refrigerants for high and low temperature cycle machines. The refrigerants used by different manufacturers are different. It is recommended that users choose environmentally friendly refrigerants better, energy saving and environmental protection.
Related recommendations
-
Introduction of LNEYA Semiconductor Temperature Test System
1913The semiconductor temperature test system is an indispensable part of the semiconductor process. The LNEYA semiconductor temperature test system is dedicated to various semiconductor tests. The semiconductor temperature test system runs through th...
View details -
Do new energy vehicle motor tests require a chiller or heater?
1244New energy vehicle motor testing requires both a chiller and a heater, as motor testing covers a wide range of temperature conditions to ensure the performance and stability of the motor under different operating conditions. Chiller: In ...
View details -
Temperature shock test chamber failure performance description
1519The temperature shock test chamber is widely used in various major industries. When users purchase, they hope that their temperature impact test chamber can be used for a long time. Therefore, it is necessary to understand each fault of the temper...
View details -
Vocs gas condensing treatment equipment compressor maintenance instructions
1513The vocs gas condensing treatment equipment is an important equipment in the process of exhaust gas treatment. Among them, the compressor is one of the main components, and its performance is affecting the operating efficiency of the entire vocs g...
View details