How to Prolong the Service Life of Glycol Chiller System?
In order to extend the service life of your glycol chiller in industrial applications, please pay attention to the following points:
1. Use automobile grade antifreeze carefully Do not use automobile grade or unqualified antifreeze. Because this glycol is not manufactured for industrial applications, it may cause a variety of problems and shorten the service life of your glycol chiller system.
2. Comply with local regulations. Experts have designed different rules and regulations according to the environmental requirements of this specific area. These are called local regulations, which not only provide safe operation, but also prolong the service life of ethylene glycol chiller system for your industrial application.
3. Fluid filtration and equipment maintenance. Another secret to prolong the service life of ethylene glycol chiller system is to use fluid filter and carry out fluid maintenance. Operate the equipment as specified in the manufacturer's manual.
4. Perform all preventive and corrective maintenance. All planned and unplanned maintenance must be performed to extend the service life of the glycol chiller system· Provide regular maintenance list for all users, such as cleaning, lubrication, dust removal and filter replacement. All inspections are completed in time according to the instructions in the manufacturer's manual.
5. On time calibration of equipment. Stickers are attached to all equipment requiring calibration. This shows the calibration date, all of which should be calibrated in time to improve the efficiency of the measuring instrument and prolong the service life of your glycol cooling system.
February 6, 2021If you need equipment to distill CBD, you need to scrutinize your choices, as the equipment can vary in its features and design. When you use equipment that produces a CBD distillate, you want to seek out a system made by a manufacturer that provides proven and reliable products. You should also work with a business that can train you on the use of the equipment you buy.view
December 5, 2022On November 18, 2022, it was sponsored by the Jiangsu Provincial Association for Science and Technology, the Provincial Taiwan Affairs Office, the Provincial Department of Industry and Information Tec...view
January 13, 2023Recently, the Jiangsu Provincial Productivity Promotion Center officially released the evaluation results of the unicorn enterprises and gazelle enterprises in 2022 in Jiangsu and the high-tech zone, ...view
January 11, 2018Industrial Chiller:Industrial Chiller varies from dynamic temp. Special Chiller:Special Chiller consist of Multi-reactor chiller (TCU).Environmental Chamber:The test object is connected to a testing adapter. Industrial Freezer:Industrial freezer consist oview
July 4, 2018What are the characteristics and functions of ultra low freezer: 1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the proce...view
January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃)
Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view