Precautions for the use of chemical refrigeration and heating circulation systems
In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relatively simple, and the process of reducing the temperature in the reactor to room temperature takes a particularly long time, and the heat energy cannot be used rationally, resulting in a waste of some resources. However, if the waste heat is released too much, the overall temperature will drop unstable, and the product quality will be affected. Therefore, it is very important to have a cooling and heating cycle system.

The characteristic of the reactor is that the volume and heat capacity are very large, and endothermic and exothermic reactions can occur at any time, so the entire process time will be lengthened when collecting. When the polymerization reaction occurs in the reactor, the chemical raw materials are changing, which will cause changes in the process and materials, and a series of endothermic and exothermic reactions occur. Therefore, the chemical production itself is very complicated.
Points for attention in the use of chemical refrigeration and heating cycle systems
(1) When the reactor is in operation, it needs to strictly follow the relevant standards to prevent over-temperature and over-pressure.
(2) Strict temperature control in accordance with requirements.
(3) It is necessary to prevent the superposition of temperature difference stress and internal pressure stress to ensure that the equipment does not appear to be strained.
(4) The ratio of ingredients must be strictly controlled to prevent violent reactions.
With the rapid development of society, in order to adapt to the current development needs of the chemical industry, it is necessary to strengthen temperature control in the chemical production process and optimize the design of the temperature control system to ensure that it meets the requirements for use and ensures the normal operation of the equipment.
Related recommendations
-
How to maintain the high and low temperature cooling constant temperature system?
325The high and low temperature cooling constant temperature system performs refrigeration and heating operation in the pharmaceutical and chemical industry. It follows the rules of operation and meticulous requirements to continuously improve its qu...
View details -
What are the characteristics and application scope of cryogenic refrigeration circulators?
356Specializing in the development and production of low-temperature refrigeration circulators, the refrigeration temperature range is from -120 degrees to -30 degrees. Today, let us take a look at the characteristics of low-temperature refrigeration...
View details -
Characteristic Analysis of Industrial Air Cooled Chiller
315Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be...
View details -
The cooling circulation system is used to collect the non-condensable tail gas in the distillation s
337Most rectification towers are two-stage condensation. The first stage uses cooling water, mainly condensing the top steam, and the second stage uses chilled water or ethylene glycol, which is mainly used to treat tail gas and remove a small amount...
View details