Precautions for the use of chemical refrigeration and heating circulation systems
In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relatively simple, and the process of reducing the temperature in the reactor to room temperature takes a particularly long time, and the heat energy cannot be used rationally, resulting in a waste of some resources. However, if the waste heat is released too much, the overall temperature will drop unstable, and the product quality will be affected. Therefore, it is very important to have a cooling and heating cycle system.
The characteristic of the reactor is that the volume and heat capacity are very large, and endothermic and exothermic reactions can occur at any time, so the entire process time will be lengthened when collecting. When the polymerization reaction occurs in the reactor, the chemical raw materials are changing, which will cause changes in the process and materials, and a series of endothermic and exothermic reactions occur. Therefore, the chemical production itself is very complicated.
Points for attention in the use of chemical refrigeration and heating cycle systems (1) When the reactor is in operation, it needs to strictly follow the relevant standards to prevent over-temperature and over-pressure. (2) Strict temperature control in accordance with requirements. (3) It is necessary to prevent the superposition of temperature difference stress and internal pressure stress to ensure that the equipment does not appear to be strained. (4) The ratio of ingredients must be strictly controlled to prevent violent reactions.
With the rapid development of society, in order to adapt to the current development needs of the chemical industry, it is necessary to strengthen temperature control in the chemical production process and optimize the design of the temperature control system to ensure that it meets the requirements for use and ensures the normal operation of the equipment.
January 11, 2018Industrial Chiller:Industrial Chiller varies from dynamic temp. Special Chiller:Special Chiller consist of Multi-reactor chiller (TCU).Environmental Chamber:The test object is connected to a testing adapter. Industrial Freezer:Industrial freezer consist oview
July 4, 2018What are the characteristics and functions of ultra low freezer: 1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the proce...view
July 4, 2018The refrigeration system of cold plate freezer adopts secondary super-cooler technology with the rapid refrigeration and low limiting temperature. It uses imported brand name semi-hermetic piston comp...view
July 4, 2018Guanya is a leading role in heating cooling circulator. It provides the customers with proposal and technology of controlling the cold and heat, temperature control system with stable property, extend...view
January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃)
Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view